Refine your search:     
Report No.
 - 

Characteristics of OSL dosimeter as individual monitoring for external radiation

Suzuki, Akifumi; Suzuki, Takehiko; Takahashi, Masa ; Nakata, Toru; Murayama, Takashi; Tsunoda, Masahiko 

Optically Stimulated Luminescence, OSL, dosimeters have been used as individual dosimeters for external radiation in Nuclear Science Research Institute and so on since October, 2014 as successor of the RPL glass dosimeters. Characteristics of the OSL dosimeters such as dose linearity, energy response, angular dependence, fading characteristics and responses at mixed irradiation fields were examined prior to the start of use. As a result, it was found that the OSL dosimeters met the performances that the national standard (JIS Z 4339) determined. The characteristics of OSL dosimeters were comparable with those of the RPL glass dosimeters. In conclusion, it was confirmed the OSL dosimeters had sufficient performances for the practical use on individual monitoring. This report shows the testing methods and the results for the characteristics of OSL dosimeters.