Refine your search�ソスF     
Report No.
 - 

Measurement of neutron production double-differential cross-sections on carbon bombarded with 430 MeV/nucleon carbon ions

Itashiki, Yutaro*; Imabayashi, Yoichi*; Shigyo, Nobuhiro*; Uozumi, Yusuke*; Satoh, Daiki   ; Kajimoto, Tsuyoshi*; Sanami, Toshiya*; Koba, Yusuke*; Matsufuji, Naruhiro*

Carbon ion therapy has achieved satisfactory results because of high curability and minimally invasiveness. However, patients have a risk to get a secondary cancer. In order to estimate the risk, it is essential to understand particle transportation and nuclear reactions in the patient's body. The particle transport Monte Carlo simulation code is a useful tool to understand them. Since the code validation for heavy ion incident reactions is not enough, the experimental data of the elementary reaction processes is needed. We measured neutron production double-differential cross-sections (DDXs) on a carbon bombarded with 430 MeV/nucleon carbon beam which is a possible candidate of future therapy beam. The experiment was performed at PH2 beam line of the HIMAC of National Institute of Radiological Sciences. The 430 MeV/nucleon carbon beam was irradiated on a 5 cm $${times}$$ 5 cm $${times}$$ 1 cm graphite target rotated 45$$^{circ}$$ to the beam axis. The beam intensity was set to 10$$^{5}$$ particles / spill. A 0.5 mm thick NE102A plastic scintillator was placed to monitor the beam intensity. Neutrons produced in the target were measured with two sizes of NE213 liquid organic scintillators located at six angles of 15, 30, 45, 60, 75, and 90$$^{circ}$$. The 5.08 cm long one was used to obtain the neutron spectra from 1 MeV to 10 MeV and the 12.7 cm long one was used above 5 MeV. The 2 mm thick NE102A plastic scintillators to discriminate charged particles were set in front of the neutron detectors. The kinetic energies of neutrons were determined by the time-of-flight (TOF) method. Background neutrons were estimated by a measurement with iron shadow bars between the target and each neutron detector. An electronic circuit for data acquisition consisted of NIM and CAMAC modules. The experimental data was compared with calculated results obtained by Monte Carlo simulation codes as PHITS. The PHITS code reproduced the experimental data well.

Accesses

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.