Refine your search:     
Report No.
 - 

Relation of the corrosion rate of carbon steel in irradiating dilute artificial seawater and the dose rate of dilute artificial seawater

Motooka, Takafumi

Relation of the corrosion rate of carbon steel in irradiating dilute artificial seawater and the dose rate was investigated by corrosion tests using Co-60 $$gamma$$ source in the atmospheric condition, quantitative analysis of test solutions and identification of rusts. The corrosion rate of carbon steel was increased with the increase of dose rate of dilute artificial seawater. Hydrogen peroxide formed by water radiolysis controlled the corrosion rate of carbon steel. The oxidation of Fe $$^{2+}$$ by oxidizing species formed by water radiolysis affected the rust formation process of the carbon steel.