Analytical study of the cladding corrosion effect on the failure limit of SPERT-CDC Test 859 by using FEMAXI-7 and RANNS Codes
FEMAXI-7及びRANNSコードを用いたSPERT-CDC Test 859の破損限界に対する被覆管腐食の影響の解析的研究
谷口 良徳
Taniguchi, Yoshinori
In the current Japanese regulation concerning fuel safety, a part of Japanese PCMI failure criteria was determined based on the result of SPERT-CDC test 859 (SPERT859). In this study, the corrosion formed on the cladding outer surface of SPERT859 test rod and the fuel enthalpy increase at PCMI failure of the test rod under the corrosion condition were estimated by using fuel performance codes FEMAXI-7 and RANNS. The result of FEMAXI-7 indicated that the cladding of the test rod had probably excessive corrosion in consideration of the effect of pellet swelling. The result of RANNS suggested that the fuel enthalpy at failure of SPERT859 was affected by the excessive corrosion on the cladding of the test rod.
- 登録番号 : BB20161238
- 抄録集掲載番号 :
- 論文投稿番号 :
[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.