Effect of O/A ratio on extraction performance of centrifugal contactor

Sakamoto, Atsushi  ; Sano, Yuichi   ; Takeuchi, Masayuki ; Watanabe, Masayuki; Koizumi, Kenji 

The effects of O/A ratio on extraction and back extraction performances of uranium in the centrifugal contactor were investigated to apply the same to the co-processing process. The centrifugal contactor was applied to the uranium extraction process with a high stage efficiency in conditions with a wide range of O/A ratios. The back extraction of uranium was achieved at an O/A ratio of less than 2 by the centrifugal contactor. In this condition, the behavior of uranium was evaluated by MIXSET-X with 90$$sim$$100% stage efficiency.