Study on combination hazard curve of forest fire with lightning and strong wind

Okano, Yasushi; Yamano, Hidemasa   

Forest fire hazard assessment methodologies using a logic tree have been applied for the evaluation of combination hazard curves of a forest fire with lightning as an initiator of a forest fire and with a strong wind being independent from a forest fire. The complex shape of the combinational hazard curve of forest fire and lighting is due to that both lightning and high velocity wind tend to appear under unstable weather conditions, and there is correlation between two hazards. The evaluated combinational hazard curve of forest fire and strong wind for the instantaneous wind velocity over 80 m/s has extremely small frequency in the range below 10$$^{-14}$$/year.