Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 39

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Improved multicomponent analysis method for electron spin resonance spectra of gamma-irradiated tooth enamel

Yamashita, Takuma*; Iwami, Satone*; Mitsuyasu, Yusuke*; Ono, Kenta*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

KEK Proceedings 2024-6, p.85 - 90, 2024/12

To clarify the radiation effects of the accident at the TEPCO's Fukushima Daiichi NPP on living organisms, it is important to accurately estimate the dose to each individual. We have developed a multi-component analysis program using random number optimization to extract only the components derived from carbonate radicals from the ESR spectra.

Journal Articles

Study on microwave power dependency of electron spin resonance spectrum of carbonate radicals in teeth

Iwami, Satone*; Yamashita, Takuma*; Mitsuyasu, Yusuke*; Ono, Kenta*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

KEK Proceedings 2024-6, p.91 - 95, 2024/12

We aim to improve the detection limit of the ESR dosimetry method. In this study, the saturation behavior of each radical was investigated by varying the microwave power during ESR measurement. Based on the difference in spin relaxation time between carbonate radicals and native radicals, it is expected that the signal-to-noise ratio improves and the detection limit can be lowered when the microwave power is increased to 4.0 mW.

Journal Articles

Estimation of external dose for wild Japanese macaques captured in Fukushima prefecture; Decomposition of electron spin resonance spectrum

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.

Radiation Protection Dosimetry, 199(14), p.1620 - 1625, 2023/09

 Times Cited Count:1 Percentile:25.62(Environmental Sciences)

We have been conducting dose assessments for Japanese macaques captured in Fukushima to reveal radiobiological effects on the low-dose expose animals. To accurately determine the external exposure dose, it is desirable to examine the analysis of the CO$$_{2}^{-}$$ radical intensity. We examined ESR spectra of teeth of 10 macaques captured in Fukushima by two spectrum-decomposition algorithms.

Journal Articles

Measurement of the longitudinal bunch-shape distribution for a high-intensity negative hydrogen ion beam in the low-energy region

Kitamura, Ryo; Futatsukawa, Kenta*; Hayashi, Naoki; Hirano, Koichiro; Kondo, Yasuhiro; Kosaka, Satoshi*; Miyao, Tomoaki*; Morishita, Takatoshi; Nemoto, Yasuo*; Oguri, Hidetomo

Physical Review Accelerators and Beams (Internet), 26(3), p.032802_1 - 032802_12, 2023/03

 Times Cited Count:3 Percentile:60.26(Physics, Nuclear)

A bunch-shape monitor (BSM) is a useful device for performing longitudinal beam tuning using the pointwise longitudinal phase distribution measured at selected points in the beam transportation. To measure the longitudinal phase distribution of a low-energy negative hydrogen (H$$^{-}$$) ion beam, highly oriented pyrolytic graphite (HOPG) was adopted for the secondary-electron-emission target to mitigate the thermal damage due to the high-intensity beam loading. The HOPG target enabled the measurement of the longitudinal phase distribution at the center of a 3-MeV H$$^{-}$$ ion beam with a high peak current of about 50 mA. The longitudinal bunch width was measured using HOPG-BSM at the test stand, which was consistent with the beam simulation. The correlation measurement between the beam transverse and longitudinal planes was demonstrated using HOPG-BSM. The longitudinal Twiss and emittance measurement with the longitudinal Q-scan method was conducted using HOPG-BSM.

Journal Articles

A Study on accuracy of analysis of the radiation-induced component in the ESR spectra of teeth

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.

KEK Proceedings 2022-2, p.120 - 125, 2022/11

We investigate the effect of sample's anisotropy and measurement condition to obtain the higher reproducibility for the shape of the ESR spectrum and the intensity of CO$$_{2}^{-}$$ radical.

Journal Articles

Detection limit of electron spin resonance for Japanese deciduous tooth enamel and density separation method for enamel-dentine separation

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; Sasaki, Keiichi*; et al.

Journal of Radiation Research (Internet), 63(4), p.609 - 614, 2022/07

AA2021-0724.pdf:0.68MB

 Times Cited Count:3 Percentile:35.92(Biology)

Electron spin resonance (ESR) dosimetry is one of the most powerful tools for radiation dose reconstruction. The detection limit of this technique using human teeth is reported to be 56 mGy or 67 mGy; however, the absorbed dose of Fukushima residents after the Fukushima Daiichi Nuclear Power Plant (FNPP) accident was estimated to be lower than this detection limit. Our aim is to assess the absorbed radiation dose of children in Fukushima Prefecture after the accident; therefore, it is important to estimate the detection limit for their teeth. The detection limit for enamel of deciduous teeth of Japanese children separated by the mechanical method is estimated to be 115.0 mGy. The density separation method can effectively separate enamel from third molars of Japanese people. As we have collected thousands of teeth from children in Fukushima, the present technique may be useful to examine their external absorbed dose after the FNPP accident.

Journal Articles

Development of dose estimation method using wild animal teeth for low dose exposure

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

KEK Proceedings 2021-2, p.91 - 96, 2021/12

We examined whether the ESR dose estimation method could be applied to wild Japanese macaque. In this work, we investigated the enamel preparation protocol and the analytical method of the ESR spectra.

Journal Articles

Rapid analysis of $$^{90}$$Sr in cattle bone and tooth samples by inductively coupled plasma mass spectrometry

Koarai, Kazuma; Matsueda, Makoto; Aoki, Jo; Yanagisawa, Kayo*; Terashima, Motoki; Fujiwara, Kenso; Kino, Yasushi*; Oka, Toshitaka; Takahashi, Atsushi*; Suzuki, Toshihiko*; et al.

Journal of Analytical Atomic Spectrometry, 36(8), p.1678 - 1682, 2021/08

 Times Cited Count:7 Percentile:53.68(Chemistry, Analytical)

Rapid analysis of $$^{90}$$Sr in bone and tooth samples of cattle were achieved by an inductively coupled plasma mass spectrometry (ICP-MS) coupled with mass shift and solid phase extraction techniques. Limit of detection (LOD) in the ICP-MS measurement of 0.1 g samples was lower than that of the radioactivity measurement. Analytical time of the ICP-MS method was reduced from 20 days to 11 hours, compared with the radiometric method. Therefore, the ICP-MS method can be rapid and useful procedure of $$^{90}$$Sr in small bone and tooth samples derived from terrestrial animals.

Journal Articles

Radioactivity and radionuclides in deciduous teeth formed before the Fukushima-Daiichi Nuclear Power Plant accident

Takahashi, Atsushi*; Chiba, Mirei*; Tanahara, Akira*; Aida, Jun*; Shimizu, Yoshinaka*; Suzuki, Toshihiko*; Murakami, Shinobu*; Koarai, Kazuma; Ono, Takumi*; Oka, Toshitaka; et al.

Scientific Reports (Internet), 11(1), p.10355_1 - 10355_11, 2021/05

 Times Cited Count:9 Percentile:40.51(Multidisciplinary Sciences)

Journal Articles

Bunch-size measurement of the high-intensity H$$^{-}$$ beam with 3 MeV by the bunch-shape monitor

Kitamura, Ryo; Futatsukawa, Kenta*; Hayashi, Naoki; Hirano, Koichiro; Kondo, Yasuhiro; Kosaka, Satoshi*; Miyao, Tomoaki*; Nemoto, Yasuo*; Morishita, Takatoshi; Oguri, Hidetomo

JPS Conference Proceedings (Internet), 33, p.011012_1 - 011012_6, 2021/03

The new bunch shape monitor (BSM) is required to measure the bunch size of the high-intensity H$$^{-}$$ beam with 3 MeV at the front-end section in the J-PARC linac. The carbon-nano tube wire and the graphene stick are good candidates for the target wire of the BSM, because these materials have the enough strength to detect the high-intensity beam. However, since the negative high voltage of more than a few kV should be applied to the wire in the BSM, the suppression of the discharge is the challenge to realize the new BSM. After the high-voltage test to investigate the effect of the discharge from the wire, the detection of the signal from the BSM was successful at the beam core with the peak current of 55 mA using the graphene stick. The preliminary result of the bunch-size measurement is reported in this presentation.

Journal Articles

Evaluation of the bunch-shape monitor for the high-intensity proton beam

Kitamura, Ryo; Futatsukawa, Kenta*; Hayashi, Naoki; Hirano, Koichiro; Kondo, Yasuhiro; Kosaka, Satoshi*; Miyao, Tomoaki*; Nemoto, Yasuo*; Morishita, Takatoshi; Oguri, Hidetomo

Proceedings of 17th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.251 - 253, 2020/09

A bunch-shape monitor (BSM) in the low-energy region is being developed in the J-PARC linac to accelerate the high-intensity proton beam with the low emittance. A highly-oriented pyrolytic graphite (HOPG) was introduced as the target of the BSM to mitigate the thermal loading. The stable measurement of the BSM was realized thanks to the HOPG target, while the tungsten target was broken by the thermal loading from the high-intensity beam. However, since the longitudinal distribution measured with the BSM using the HOPG target was wider than the expected one, the improvement of tuning parameters is necessary for the BSM. The BSM consists of an electron multiplier, a bending magnet, and a radio-frequency deflector, which should be tuned appropriately. Behavior of these components were investigated and tuned. The longitudinal distribution measured with the BSM after the tuning was consistent with the expected one.

Journal Articles

External exposure dose estimation by electron spin resonance technique for wild Japanese macaque captured in Fukushima Prefecture

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; et al.

Radiation Measurements, 134, p.106315_1 - 106315_4, 2020/06

 Times Cited Count:9 Percentile:65.08(Nuclear Science & Technology)

The relationship between the CO$$_{2}$$ radical intensity and the absorbed dose (dose response curve) of tooth enamel of Japanese macaque was observed by electron spin resonance and the detection limit of our system was estimated to be 33.5 mGy, which is comparable to the detection limit for human molar teeth. Using the dose response curve, external exposure dose for seven wild Japanese macaques captured in Fukushima prefecture were examined. The results suggest that the external exposure dose for the wild Japanese macaques were ranged between 45 mGy to 300 mGy.

Journal Articles

Bunch shape monitor for the high-intensity H$$^{-}$$ beam with 3 MeV using the carbon material

Kitamura, Ryo; Futatsukawa, Kenta*; Hayashi, Naoki; Hirano, Koichiro; Kosaka, Satoshi*; Miyao, Tomoaki*; Moriya, Katsuhiro; Nemoto, Yasuo*; Oguri, Hidetomo

Proceedings of 16th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.51 - 54, 2019/07

The longitudinal measurement and tuning at the beam transport after the RFQ are important to reduce the beam loss and the emittance growth in the J-PARC linac, when the high-intensity H$$^{-}$$ beam of more than 60 mA is supplied. The new bunch shape monitor (BSM) using the carbon-nanotube (CNT) wire is necessary to measure the bunch shape of the high-intensity H$$^{-}$$ beam with 3 MeV, because the CNT wire has a high-temperature tolerance and a small energy deposit. However, when the high voltage was applied to the CNT wire to extract the secondary electron derived, the discharge prevents the power supply from applying the voltage. Therefore, the discharge should be suppressed to measure the bunch shape with stability. Considering the characteristics of the CNT as the emitter, when the length of the CNT wire was short, the high voltage of -10 kV was applied to the CNT wire. The current status and future prospects of the BSM using the CNT wire are reported in this presentation.

Journal Articles

Development of evaluation method for variability of groundwater flow conditions associated with long-term topographic change and climate perturbations

Onoe, Hironori; Kosaka, Hiroshi*; Matsuoka, Toshiyuki; Komatsu, Tetsuya; Takeuchi, Ryuji; Iwatsuki, Teruki; Yasue, Kenichi

Genshiryoku Bakkuendo Kenkyu (CD-ROM), 26(1), p.3 - 14, 2019/06

In this study, it is focused on topographic changes due to uplift and denudation, also climate perturbations, a method which is able to assess the long-term variability of groundwater flow conditions using the coefficient variation based on some steady-state groundwater flow simulation results was developed. Spatial distribution of long residence time area which is not much influenced due to long-term topographic change and recharge rate change during the past one million years was able to estimate through the case study of the Tono area, Central Japan. By applying this evaluation method, it is possible to identify the local area that has low variability of groundwater flow conditions due to topographic changes and climate perturbations from the regional area quantitatively and spatially.

Journal Articles

Development of the bunch shape monitor using the carbon-nano tube wire

Kitamura, Ryo; Hayashi, Naoki; Hirano, Koichiro; Kondo, Yasuhiro; Moriya, Katsuhiro; Oguri, Hidetomo; Futatsukawa, Kenta*; Miyao, Tomoaki*; Otani, Masashi*; Kosaka, Satoshi*; et al.

Proceedings of 10th International Particle Accelerator Conference (IPAC '19) (Internet), p.2543 - 2546, 2019/06

A bunch shape monitor (BSM) is one of the important instruments to measure the longitudinal phase space distribution. For example in the J-PARC linac, three BSMs using the tungsten wire are installed at the ACS section to measure the bunch shapes between the accelerating cavities. However, this conventional BSM is hard to measure the bunch shape of H$$^{-}$$ beam with 3 MeV at the beam transport between the RFQ and DTL sections, because the wire is broken around the center region of the beam. The new BSM using the carbon-nano-tube (CNT) wire is being developed to be able to measure the bunch shape of the H$$^{-}$$ beam with 3 MeV. The careful attention should be paid to apply the high voltage of $$-$$10 kV to the CNT wire. The several measures are taken to suppress the discharge from the wire and operate the CNT-BSM. This presentation reports the current status of the development and future prospective for the CNT-BSM.

Journal Articles

Development of methodology for the characterisation of the long-term geosphere evolution, 2; Estimation of the long-term evolution of groundwater flow conditions in a Tono area case study

Kosaka, Hiroshi; Saegusa, Hiromitsu; Yasue, Kenichi; Kusano, Tomohiro; Onoe, Hironori

Proceedings of 19th International Conference on Nuclear Engineering (ICONE-19) (CD-ROM), 9 Pages, 2011/10

The methodology for estimation of the long-term evolution of groundwater flow conditions are being developed using approaches on the basis of deductive and inductive methods in the case of Tono area. Based on the studies using the approach on the basis of deductive method, it has been confirmed that the method combining physical modeling of topographic change and groundwater flow simulations is useful for estimating of changes in groundwater flow conditions in the future due to topographic and climatic perturbations. Existing information for estimation of surface hydrological conditions, which are to be used for assignment of boundary conditions for the groundwater flow simulation, has been gathered from many sources and reviewed based on modern-analogue methods. In the studies using the approach on the basis of inductive method, paleo-hydrogeological studies have been carried out on several spatial and time scales. Through the study on the largest spatial scale, a methodology needed to understand changes of groundwater flow conditions due to long-term topographic change is proposed to efficiently identify the area to be carried out site characterization involving field investigations. And then, information to estimate the paleo-topography and paleo-climate has been obtained from literature surveys and field investigations. Through these studies, it has been confirmed that these two approaches are useful for estimation of the long-term evolution of deep groundwater flow conditions.

Oral presentation

Sample preparation procedure for the estimation of external exposure dose of wild animals using elecron spin resonance spectroscopy

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

Release of the radioactive materials from Fukushima Daiichi Nuclear Power Plant accident results in a long-term low dose rate ionization exposure to wild animals. The biological effects of the wild animal do not show a clear correlation with the external dose, which is estimated from the external dose rate of the captured point of the animal, a precise external dose estimation using ESR and tooth enamel is required instead of using the external dose rate. In this work, we attempted to estimate the external dose of wild Japanese macaque and Procyon lotor captured in the high dose rate area.

Oral presentation

External exposure dose of Japanese macaque captured in Fukushima prefecture

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; et al.

no journal, , 

Due to the Fukushima Daiichi Nuclear Power Plant accident, the exposure dose estimation for human is examined by the whole body counter or by the Fukushima Health Management Survey, however, the precise estimated dose cannot obtained by such methods. We applied electron spin resonance (ESR) dosimetry for the external dose estimation using tooth enamel of human/animal. As we reported last year, we improved the detection limit of ESR dosimetry down to 43 mGy. We used this improved ESR dosimetry system and attempted to estimate the external dose of wild Japanese macaque capture in Fukushima prefecture, however, the metal component which may obstruct the ESR measurement was observed, so that we cannot estimate the external dose. In this work, we investigated how to remove such metal components, obtain the clear ESR spectrum, and estimate the external dose.

Oral presentation

Sample preparation procedure for ESR dosimetry using teeth of wild animal

Oka, Toshitaka; Mitsuyasu, Yusuke*; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Sekine, Tsutomu*; Okutsu, Kenichi*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

Releases of the radioactive materials from the Fukushima Daiichi Nuclear Power Plant accident result in a low dose exposure to wild animals. The external dose of wild animals is commonly estimated by the external dose rate of the captured point, but the estimated exposure dose has huge uncertainties because the size of the habitat and/or the movement of the wild animals are not included in the estimation. To estimate the external dose precisely, we utilize electron spin resonance (ESR) dosimetry. In this work, we investigated the sample preparation procedure of wild animals. The ESR spectrum of enamel of racoon captured in Namie-town, Fukushima has a broad ESR signal due to metal components. The linear relationship between the Co$$_{2}$$ intensity and the absorbed dose that we can apply ESR dosimetry for racoon teeth. Using this relationship, the external exposure dose was estimated.

Oral presentation

Dose estimation for animals exposed low dose using their teeth

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

The improvement of the ESR dosimetry is required to apply that for the low-dose exposure of wild animals. We will report our progress of the improvement, and compare the external exposure dose estimated by the ESR dosimetry technique and the calculated result based on the external exposure dose rate of the captured point.

39 (Records 1-20 displayed on this page)