Kobayashi, Yuki; Takahashi, Tetsuro; Shinozaki, Tadahiro; Ogasawara, Koji; Koizumi, Kenji; Nakajima, Yasuo
Nihon Hozen Gakkai Dai-7-Kai Gakujutsu Koenkai Yoshishu, p.161 - 166, 2010/07
The negative pressure control valve is reliable apparatus which has been used in many nuclear facilities. In recent years, there are some troubles on those valves in CPF (Chemical Reprocessing Facility) by the aged deterioration because the valves were kept using for more than 25 years after facility had operated. Therefore, we have been carrying out renewal of driving units of the valves to assure performance of negative pressure control function and to keep stability of operation of the facility. In this presentation, we report knowledge provided through the renewal work, such as the renewal procedure, the deterioration situation of components and the cause of troubles.
Makino, Risa; Tomikawa, Hirofumi; Hina, Tetsuro; Ozone, Takashi; Kurosu, Kazutoshi; Fukuhara, Junichi; Kobayashi, Kentaro; Kabuki, Toshihide*
Kaku Busshitsu Kanri Gakkai (INMM) Nihon Shibu Dai-27-Kai Nenji Taikai Rombunshu (CD-ROM), 7 Pages, 2006/00
Tokai Reprocessing Center has developed method of determination of Pu contained in low activity solid wastes (LASWs), to make better accountancy control. Our final goal is to estimate of Pu amounts in wastes generated in TRP. Some of small size wastes (carton-boxes) and drums from TRP was measured by some kind of non-destructive assay system. It was found that high dose wastes have slight amounts of Pu. However, because some of wastes from TRP have Cm, the wastes could not be measured exactly. Near future, JAEA will try upgrading or development of NDA system, and determination of Pu amount of wastes from TRP.
*; *; *
PNC TN3720 88-007, 235 Pages, 1988/03
As the irradiation test in developing high-burnup fuels for the ATR, a loading of MOX fuel assembly containing UO-GdO fuel rods to the "FUGEN" is planning. We have analyzed and evaluated the intergrity and the safety of these fuels based on the safety examination guides. The appendix 10 of the application document for permission of nuclear reactor establishment and amendment of the "FUGEN" were revised. The present report describes the results of these investigation refeing to the appendix 10 for LWRs.
; ; ; *; *; *
JAERI-M 6646, 27 Pages, 1976/08
no abstracts in English
*; *; ; ; *; *; ; ;
JAERI-M 6470, 14 Pages, 1976/03
no abstracts in English
; ; ; *; *; *
JAERI-M 6469, 20 Pages, 1976/03
no abstracts in English
; *; ; Takeda, Tatsuoki; ; *; ; *
JAERI-M 6467, 32 Pages, 1976/03
no abstracts in English
*; ; Takeda, Tatsuoki; *; ; ; *
JAERI-M 6451, 62 Pages, 1976/03
no abstracts in English
Makino, Risa; Kabuki, Toshihide*; Tomikawa, Hirofumi; Hina, Tetsuro; Ozone, Takashi; Kurosu, Kazutoshi; Fukuhara, Junichi; Kobayashi, Kentaro
no journal, ,
Tokai Reprocessing Center has developed method of determination of Pu contained in low activity solid wastes (LASWs), to make better accountancy control. Our final goal is to estimate of Pu amounts in wastes generated in Tokai Reprocessing Plant (TRP). Some of small size wastes (carton-boxes) and drums from TRP was measured by some kind of non-destructive assay system. It was found that high dose wastes have slight amounts of Pu. However, because some of wastes from TRP have FPs, the wastes could not be measured exactly. Near future, JAEA will try upgrading or development of NDA system, and determination of Pu amount of wastes from TRP.
Kobayashi, Yuki; Takahashi, Tetsuro; Shinozaki, Tadahiro; Ogasawara, Koji; Koizumi, Kenji; Nakajima, Yasuo
no journal, ,
The negative pressure control valve is reliable apparatus which has been used in many nuclear facilities. In recent years, there are some troubles on those valves in CPF (Chemical Reprocessing Facility) by the aged deterioration because the valves were kept using for more than 25 years after facility had operated. Therefore, we have been carrying out renewal of driving units of the valves to assure performance of negative pressure control function and to keep stability of operation of the facility. In this presentation, we report knowledge provided through the renewal work, such as the renewal procedure, the deterioration situation of components and the cause of troubles.