Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
有馬 寛*; 高田 慎一; 笠井 聡*; 大内 啓一*; 森川 利明*; 宮田 登*; 宮崎 司*; 青木 裕之; 岩瀬 裕希*; 廣井 孝介; et al.
Journal of Applied Crystallography, 56(6), p.1802 - 1812, 2023/12
被引用回数:0 パーセンタイル:0.02(Chemistry, Multidisciplinary)The contrast-variation technique in neutron scattering experiments plays a pivotal role in distinguishing partial structures within multi-component complexes, facilitating the elucidation of distinct sample constituents. This differentiation is achieved using different isotopes, namely hydrogen and deuterium, which possess varying neutron scattering characteristics. This study presents a novel vapor generator designed for neutron scattering experiments, enabling continuous control of the DO/HO ratio of the vapor. This feature is especially useful for contrast-variation studies. The generator features two saturators and four mass flow controllers, allowing for the rapid and independent generation of DO/HO vapors. Additionally, the incorporation of the two-temperature method ensures accurate dew point control within a margin of 0.2Cdp. This setup proves useful for conducting time-resolved experiments and can accelerate research on functional polymers, such as polymer electrolyte membranes for fuel cells, where water potential assumes critical importance.
赤城 卓*; 八木 雅史*; 山下 智弘*; 村上 昌雄*; 山川 善之*; 北村 圭司*; 小倉 浩一; 近藤 公伯; 河西 俊一*
Radiation Measurements, 59, p.262 - 269, 2013/12
被引用回数:17 パーセンタイル:77.87(Nuclear Science & Technology)陽子線癌治療では体内のCあるいはOと陽子線の相互作用によって陽電子放出核が生成される。この陽電子放出核に起因する陽電子の消滅放射線をPET装置でモニタリングすることによって陽子線の到達深さと照射線量を確かめる方法の研究が行われている。我々は、通常の陽子線治療施設で使われている装置を使って、照射線量を評価するために必要な陽電子放出核生成断面積を測定する方法を研究している。高感度PETスキャナー装置を使用し陽電子放出核に起因する消滅放射線の強度の時間変化を測定することによって4つの反応反応(O(p,pn)O, O(p,3p3n)C, O(p,2p2n)N, C(p,pn)C)の断面積を評価した。その結果、O(p,pn)O反応の結果は以前の測定結果とよく一致した。一方、C(p,pn)C反応の結果は以前の測定より低い値であった。
余語 覚文; 前田 拓也; 堀 利彦; 榊 泰直; 小倉 浩一; 西内 満美子; 匂坂 明人; Bolton, P.; 村上 昌雄*; 河西 俊一; et al.
Nuclear Instruments and Methods in Physics Research A, 653(1), p.189 - 192, 2011/10
被引用回数:9 パーセンタイル:56.81(Instruments & Instrumentation)We report on the development of quasi-monoenergetic proton irradiation system driven by laser and its application to radiobiological studies. Protons accelerated by W/cm laser pulses are energy-selected by quadruple-dipole magnets (QDM) and delivered with an energy peak at 2.25 MeV and energy spread of 0.66 MeV on the full width at half maximum (FWHM). Cell survival ratio is measured with a colony formation assay for cell samples from human salivary grand tumor (HSG cells) after the proton irradiation up to 8 Gy with successive bunches having a dose rate of Gy/s. We report on the results of RBE (relative biological effectiveness) measurement, which is the first one for laser-accelerated ions.
余語 覚文; 前田 拓也*; 堀 利彦*; 榊 泰直; 小倉 浩一; 西内 満美子; 匂坂 明人; Bolton, P.; 村上 昌雄*; 河西 俊一*; et al.
Proceedings of SPIE Europe Optics + Optoelectronics 2011, Vol.8079, 8 Pages, 2011/04
Human cancer cells are irradiated by laser-driven quasi-monoenergetic protons. Laser pulse intensities at the W/cm level provide the source and acceleration field for protons that are subsequently transported by four energy-selective dipole magnets. The transport line delivers 2.25 MeV protons with an energy spread of 0.66 MeV and a bunch duration of 20 ns. The survival fraction of in-vitro cells from a human salivary gland tumor is measured with a colony formation assay following proton irradiation at dose levels up to 8 Gy, for which the single bunch does rate is Gy/s and the effective dose rate is 0.2 Gy/s for 1-Hz repetition of irradiation. Relative biological effectiveness at the 10% survival fraction is measured to be using protons with a linear energy transfer of keV/m.
余語 覚文; 前田 拓也; 堀 利彦; 榊 泰直; 小倉 浩一; 西内 満美子; 匂坂 明人; 桐山 博光; 岡田 大; 金沢 修平; et al.
Applied Physics Letters, 98(5), p.053701_1 - 053701_3, 2011/02
被引用回数:98 パーセンタイル:94.24(Physics, Applied)Human cancer cells are irradiated by laser-driven quasi-monoenergetic protons. Laser pulse intensities at the W/cm level provide the source and acceleration field for protons that are subsequently transported by four energy-selective dipole magnets. The transport line delivers 2.25 MeV protons with an energy spread of 0.66 MeV and a bunch duration of 20 ns. The survival fraction of in-vitro cells from a human salivary gland tumor is measured with a colony formation assay following proton irradiation at dose levels up to 8 Gy, for which the single bunch does rate is Gy/s and the effective dose rate is 0.2 Gy/s for 1-Hz repetition of irradiation. Relative biological effectiveness at the 10% survival fraction is measured to be using protons with a linear energy transfer of 17.1 keV/m.
余語 覚文; 佐藤 克俊; 錦野 将元; 森 道昭; 手島 昭樹*; 沼崎 穂高*; 村上 昌雄*; 出水 祐介*; 赤城 卓*; 永山 伸一*; et al.
Applied Physics Letters, 94(18), p.181502_1 - 181502_3, 2009/05
被引用回数:110 パーセンタイル:94.69(Physics, Applied)We report the demonstrated irradiation effect of laser-accelerated protons on human cancer cells. (living) A549 cells are irradiated with quasi-monoenergetic proton bunches of 0.8-2.4 MeV with a single bunch duration of 15 ns. Irradiation with the proton dose of 20 Gy results in a distinct formation of -H2AX foci as an indicator of DNA double-strand breaks generated in the cancer cells. This is a pioneering result in view of future investigations on the radiobiological effects of laser-driven ion beams. Unique high-current and short-bunch features make laser-driven proton bunches an excitation source for time-resolved determination of radical yields.
余語 覚文; 佐藤 克俊; 錦野 将元; 前田 拓也; 西内 満美子; 榊 泰直; 堀 利彦; 森 道昭; 小倉 浩一; 織茂 聡; et al.
no journal, ,
レーザー駆動加速装置が治療に用いられることを想定して、レーザー駆動による陽子線を用いた細胞生物学実験を実施した。実験では、機構のJ-KAREN装置からの超短パルスレーザー(パルス幅:40fs,エネルギー:1.8J,中心波長:800nm)を510W/cmの集光強度で厚さ12.5mのポリイミド薄膜に照射し、最大エネルギー4MeVの連続スペクトルを持つ陽子線を発生させ、磁場分析器でエネルギーを選別した後、薄膜窓を介して培養状態のヒト肺腺がん細胞株に照射した。陽子線バンチの時間幅は20ns、ビームフラックスは10cms、1バンチによる吸収線量は約1Gyであった。この結果、吸収線量あたりの2本鎖切断収量を測定して、生物効果を示す指標である、生物学的効果比(RBE: Relative Biological Effectiveness)を、レーザー駆動粒子線として初めて評価することができた。
余語 覚文; 佐藤 克俊*; 錦野 将元; 森 道昭; 手島 昭樹*; 沼崎 穂高*; 村上 昌雄*; 小倉 浩一; 匂坂 明人; 織茂 聡; et al.
no journal, ,
高強度レーザー-プラズマ相互作用を用いて、最大エネルギー約2.5MeVの陽子線を発生させ、これを培養状態(in-vitro)のヒト肺腺がん細胞に照射して、その生物学的効果を評価した。H2AX免疫蛍光染色法によるDNA損傷評価を行った結果、陽子線20Gyを照射したサンプルに対して、DNA2本鎖切断の発生を示す結果を得た。講演では、レーザー駆動陽子線の特徴についても議論する。
余語 覚文; 西内 満美子; 榊 泰直; 堀 利彦; 佐藤 克俊; 錦野 将元; 前田 拓也; 森 道昭; 小倉 浩一; 織茂 聡; et al.
no journal, ,
高強度・短パルスのレーザーを用いたイオン加速は、1MV/mに及ぶ急峻な電場勾配を発生するため、従来のイオン加速器を大幅に小型化する技術として注目されている。レーザー駆動イオン加速装置の特徴の1つとして、シンクロトロンなど通常のがん治療に使われている加速器と比較して、高電流・短時間幅のイオンビームを発生することが挙げられる。将来的に、レーザー駆動加速装置が治療に用いられることを想定して、前述のような特徴を持つレーザー駆動陽子線の生物学的効果を、実験的に究明する必要がある。この目的のために、レーザー駆動による陽子線の細胞照射装置を開発し、生物学的影響を評価する実験を開始した。照射装置の開発の現状と、ヒト由来のがん細胞に対して照射実験を行った結果について報告する。
余語 覚文; 佐藤 克俊*; 錦野 将元; 森 道昭; 手島 昭樹*; 沼崎 穂高*; 村上 昌雄*; 小倉 浩一; 匂坂 明人; 織茂 聡; et al.
no journal, ,
高強度レーザー駆動による、MeVエネルギー陽子線の細胞照射装置を開発した。レーザー駆動加速では、陽子線と同時に、X線,電子線が発生するため、照射装置は永久磁石による分別装置を備えている。また、生きた培養状態(in-vitro)の細胞に対して陽子線を照射するために、培養液の圧力を1気圧に保ったままの状態で細胞をカプセルに密封して、これを真空中に導入する装置を開発した。このほか、発表では20Gyのレーザー駆動陽子線を照射したヒト肺腺がん細胞の照射効果についても紹介する。
余語 覚文; 前田 拓也*; 堀 利彦*; 榊 泰直; 小倉 浩一; 西内 満美子; 匂坂 明人; Bolton, P.; 村上 昌雄*; 近藤 公伯
no journal, ,
Human cancer cells are irradiated by laser-driven quasi-monoenergetic protons. Laser pulse intensities at the 510-W/cm level provide the source and acceleration field for protons that are subsequently transported by four energy-selective dipole magnets. The transport line delivers 2.25 MeV protons with an energy spread of 0.66 MeV and a bunch duration of 20 ns. The survival fraction of in-vitro cells from a human salivary gland tumor is measured with a colony formation assay following proton irradiation at dose levels up to 8 Gy, for which the single bunch does rate is 1 10 Gy/s and the effective dose rate is 0.2 Gy/s for 1-Hz repetition of irradiation. Relative biological effectiveness at the 10% survival fraction is measured to be 1.200.11 using protons with a linear energy transfer of 17.12.8 keV/m.