検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 4 件中 1件目~4件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Study of the $$N=32$$ and $$N=34$$ shell gap for Ti and V by the first high-precision multireflection time-of-flight mass measurements at BigRIPS-SLOWRI

飯村 俊*; Rosenbusch, M.*; 高峰 愛子*; 角田 佑介*; 和田 道治*; Chen, S.*; Hou, D. S.*; Xian, W.*; 石山 博恒*; Yan, S.*; et al.

Physical Review Letters, 130(1), p.012501_1 - 012501_6, 2023/01

 被引用回数:1 パーセンタイル:95.71(Physics, Multidisciplinary)

The atomic masses of $$^{55}$$Sc, $$^{56,58}$$Ti, and $$^{56-59}$$V have been determined using the high-precision multireflection time-of-flight technique. The radioisotopes have been produced at RIKEN's Radioactive Isotope Beam Factory (RIBF) and delivered to the novel designed gas cell and multireflection system, which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For $$^{56,58}$$Ti and $$^{56-59}$$V, the mass uncertainties have been reduced down to the order of 10 keV, shedding new light on the $$N=34$$ shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species $$^{58}$$Ti and $$^{59}$$V. With the new precision achieved, we reveal the nonexistence of the $$N=34$$ empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied $$nu$$p$$_{3/2}$$ orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the $$nu$$d$$_{5/2}$$ and $$nu$$g$$_{9/2}$$ orbits and compare the results with conventional shell model calculations, which exclude the $$nu$$g$$_{9/2}$$ and the $$nu$$d$$_{5/2}$$ orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at $$N = 34$$.

論文

Development and operation of an electrostatic time-of-flight detector for the Rare RI storage Ring

長江 大輔*; 阿部 康志*; 岡田 俊祐*; 大甕 舜一朗*; 若山 清志*; 細井 駿*; 鈴木 伸司*; 森口 哲朗*; 天野 将道*; 上岡 大起*; et al.

Nuclear Instruments and Methods in Physics Research A, 986, p.164713_1 - 164713_7, 2021/01

 被引用回数:5 パーセンタイル:66.98(Instruments & Instrumentation)

An electrostatic time-of-flight detector named E-MCP has been developed for quick diagnostics of circulating beam and timing measurement in mass spectrometry at the Rare-RI Ring in RIKEN. The E-MCP detector consists of a conversion foil, potential grids, and a microchannel plate. Secondary electrons are released from the surface of the foil when a heavy ion hits it. The electrons are accelerated and deflected by 90$$^{circ}$$ toward the microchannel plate by electrostatic potentials. A thin carbon foil and a thin aluminum-coated mylar foil were used as conversion foils. We obtained time resolutions of 69(1) ps and 43(1) ps (standard deviation) for a $$^{84}$$Kr beam at an energy of 170 MeV/u when using the carbon and the aluminum-coated mylar foils, respectively. A detection efficiency of approximately 90% was obtained for both foils. The E-MCP detector equipped with the carbon foil was installed inside the Rare-RI Ring to confirm particle circulation within a demonstration experiment on mass measurements of nuclei around $$^{78}$$Ge produced by in-flight fission of uranium beam at the RI Beam Factory in RIKEN. Periodic time signals from circulating ions were clearly observed. Revolution times for $$^{78}$$Ge, $$^{77}$$Ga, and $$^{76}$$Zn were obtained. The results confirmed successful circulation of the short-lived nuclei inside the Rare-RI Ring.

論文

A Multi-reflection time-of-flight mass spectrograph for short-lived and super-heavy nuclei

Schury, P. H.*; 和田 道治*; 伊藤 由太*; Naimi, S.*; 園田 哲*; 三田 浩希*; 高峰 愛子*; 岡田 邦宏*; Wollnik, H.*; Chon, S.*; et al.

Nuclear Instruments and Methods in Physics Research B, 317(Part B), p.537 - 543, 2013/12

 被引用回数:27 パーセンタイル:89.23(Instruments & Instrumentation)

極短寿命の原子核の高精度質量測定を実現する目的のために、理化学研究所において多反射時間飛行法(MRTOF)による質量分析を実施した。とりわけ大きな興味の対象としているのはr過程元素合成や超ウラン原子核の質量測定である。このような原子核に対しては、MRTOFはこれまで伝統的に質量測定に使われてきたペニングトラップ法に比べてよりよいパフォーマンスを与えることができる。われわれはMRTOFが与える質量測定の相対精度が$$10^{-7}$$にまで達し、そして重く、短寿命な原子核に適用可能であることをいくつかの実例を示しながら紹介する。

論文

Development of a resonant laser ionization gas cell for high-energy, short-lived nuclei

園田 哲*; 和田 道治*; 富田 英生*; 坂本 知佳*; 高塚 卓旦*; 古川 武*; 飯村 秀紀; 伊藤 由太*; 久保 敏幸*; 松尾 由賀利*; et al.

Nuclear Instruments and Methods in Physics Research B, 295, p.1 - 10, 2013/01

 被引用回数:20 パーセンタイル:83.94(Instruments & Instrumentation)

ガスセル中でのレーザー共鳴イオン化を用いた新しいタイプのイオン源を開発した。このイオン源は、ガスセル中に入射した放射性核種の原子を、レーザーでイオン化して、オンラインで質量分離するためのものである。このイオン源の特長は、ガスセルからイオンを引き出す出口に六極イオンガイドを付けて差動排気することにより、同位体分離装置を高真空に保ちながらガスセルの出口径を大きくした点にある。これによって、ガス中でイオン化されたイオンの引出し時間が短くなり、より短寿命の放射性核種の分離が可能となった。このイオン源は、理化学研究所の放射性イオンビーム施設(RIBF)で使用される予定である。

4 件中 1件目~4件目を表示
  • 1