検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 30 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Neutron transmission CB-KID imager using samples placed at room temperature

石田 武和*; Vu, TheDang*; 宍戸 寛明*; 相澤 一也; 奥 隆之; 及川 健一; 原田 正英; 小嶋 健児*; 宮嶋 茂之*; 小山 富男*; et al.

Journal of Low Temperature Physics, 214(3-4), p.152 - 157, 2024/02

 被引用回数:0 パーセンタイル:0.02(Physics, Applied)

We built a new cryostat to apply a current-biased kinetic inductance detector (CB-KID) for conducting neutron transmission imaging of room temperature samples under pulsed neutrons. A Wood's metal alloy of melting temperature 75.2$$^{circ}$$C was placed at room temperature to inspect the measurement system at J-PARC. Since one of the four phases of Wood's metal is a fine Cd-rich needle phase (width $$sim$$ 25 $$mu$$m and length $$sim$$ 5 mm), it is suitable for observing fine mosaic structure selectively by neutron imaging. The spatial resolution of the CB-KID imager was estimated as $$sim$$ 10 $$mu$$m by using a Gd Siemens-star pattern. The CB-KID system is useful to conduct transmission imaging for various materials rather easily at room temperature.

論文

Orientation mapping of YbSn$$_{3}$$ single crystals based on Bragg-dip analysis using a delay-line superconducting sensor

宍戸 寛明*; Vu, TheDang*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; 宮嶋 茂之*; et al.

Journal of Applied Crystallography, 56(4), p.1108 - 1113, 2023/08

 被引用回数:0 パーセンタイル:0.02(Chemistry, Multidisciplinary)

Recent progress in high-power pulsed neutron sources has stimulated the development of the Bragg dip and Bragg edge analysis methods using a two-dimensional neutron detector with high temporal resolution to resolve the neutron energy by the time-of-flight method. A delay-line current-biased kinetic inductance detector (CB-KID) is a two-dimensional superconducting sensor with a high temporal resolution and multi-hit capability. Here, it is demonstrated that a delay-line CB-KID with a $$^{10}$$B neutron conversion layer can be applied to high-spatial-resolution neutron transmission imaging and spectroscopy up to 100 eV. Dip structures are observed in the transmission spectra of YbSn$$_{3}$$ single crystals, induced by Bragg diffraction and nuclear resonance absorption. The orientation mapping of YbSn$$_{3}$$ crystals is successfully drawn based on the analysis of observed Bragg dip positions in the transmission spectra.

論文

Anomalous behavior of liquid molecules near solid nanoparticles; Novel interpretation on thermal conductivity enhancement in nanofluids

橋本 俊輔*; 山口 聡*; 原田 雅史*; 中島 健次; 菊地 龍弥*; 大石 一城*

Journal of Colloid and Interface Science, 638, p.475 - 486, 2023/05

 被引用回数:2 パーセンタイル:66.51(Chemistry, Physical)

最近、粒子分率から計算される理論的に予測された値と比較して、ベース液体と分散された固体ナノ粒子で構成されるナノ流体の熱伝導率の異常な改善が報告されている。一般に、気体と液体の熱伝導率の値は、並進運動中の分子の平均自由行程によって支配される。ここでは、ナノ粒子の周りの液体分子の振動挙動がこれらの熱伝導率の増加に寄与している可能性を示す確かな証拠を提示する。

論文

High spatial resolution neutron transmission imaging using a superconducting two-dimensional detector

宍戸 寛明*; 西村 和真*; Vu, TheDang*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; et al.

IEEE Transactions on Applied Superconductivity, 31(9), p.2400505_1 - 2400505_5, 2021/12

 被引用回数:0 パーセンタイル:0(Engineering, Electrical & Electronic)

中性子イメージングは、重金属に対する高透過性、軽元素に対する高感度、同位体と中性子との特異な核反応による同位体選択性などの中性子ビームの特徴を活かした非破壊検査の有力な手段の一つである。本研究では、超伝導検出器である電流バイアス運動インダクタンス検出器(CB-KID)を用いて、パルス中性子源を用いた飛行時間法による波長分解中性子イメージングを行った。遅延時間型CB-KIDを用いて、GdAl$$_{3}$$単結晶を成長させたGd-Al合金試料の中性子透過像を取得した。その結果、単結晶はAl-Gd合金全体に渡って、形状,分布ともに良好に観察することができた。また、中性子の波長0.03nm以上でGdによる特徴的な中性子の吸収を確認した。さらに、15$$mu$$m$$ times$$ 12$$mu$$mという限られた検出面で、同位体と中性子の核反応によって生じる$$^{155}$$Gd共鳴ディップを観測することができた。また、$$^{155}$$Gdの共鳴ディップを用いてGd選択的イメージングを行ったところ、中性子の波長幅が1pmという限られた範囲で、明確なGd核の元素選択イメージング像を取得することに成功した。

論文

Practical tests of neutron transmission imaging with a superconducting kinetic-inductance sensor

Vu, TheDang; 宍戸 寛明*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; 宮嶋 茂之*; et al.

Nuclear Instruments and Methods in Physics Research A, 1006, p.165411_1 - 165411_8, 2021/08

 被引用回数:1 パーセンタイル:18.91(Instruments & Instrumentation)

We found that the sizes of the Gd islands determined from the transmission image correlated strongly with those determined from the SEM image. We demonstrated the CB-KID could be used to identify (1) tiny voids in a thermally sprayed continuous Gd$$_2$$O$$_3$$ film in and (2) various mosaic morphologies and different eutectic microstructures in Wood's metal samples. The fact that the CB-KID system could be used to identify features of samples with a wide distribution of sizes and thicknesses is promising for real application of the device for imaging samples of interest to material scientists. Operating the CB-KID at higher temperatures appreciably improved the efficiency for simultaneously identifying the X and Y positions of hotspots. We also compared the detection efficiency with the PHITS simulations. We now plan to improve the detection efficiency by increasing the thickness of the $$^{10}$$B neutron conversion layer

論文

Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector

Vu, TheDang; 宍戸 寛明*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 奥 隆之; 曽山 和彦; 相澤 一也; et al.

Superconductor Science and Technology, 34(1), p.015010_1 - 015010_10, 2021/01

 被引用回数:3 パーセンタイル:27.71(Physics, Applied)

We demonstrated that a four-readout superconducting neutron imaging system shows good spatial heterogeneity and linearity using the delay-line method. We examined the precise pattern of a $$^{10}$$B-dot-array absorber and found the X-direction pitch (Px) = 250.7 um with a scatter of (Hx)= 5.4 um and the Y-direction pitch (Py)= 249.1 um with a scatter of (Hy)= 3.4 um while the $$^{10}$$B dot array was fully extended toward the X direction across the detector sensitive area. We consider that this demonstrates detection with good spatial homogeneity and conclude. The transmission-imaging system is suitable for use at pulsed neutron facilities. We also reported a clear transmission image of tiny screws and nuts, and ladybug (insect). We recognize that further efforts to improve the detection efficiency are necessary to make using the detector more practical.

論文

Energy-resolved neutron imaging using a delay line current-biased kinetic-inductance detector

宍戸 寛明*; 西村 和真*; Vu, TheDang*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 日高 睦夫*; 奥 隆之; et al.

Journal of Physics; Conference Series, 1590, p.012033_1 - 012033_8, 2020/10

 被引用回数:0 パーセンタイル:0.01(Engineering, Electrical & Electronic)

We demonstrate the development of an energy resolved neutron transmission imaging system via a solid-state superconducting detector, called current-biased kinetic-inductance detector (CB-KID). CB-KIDs comprise X and Y superconducting Nb meanderlines with Nb ground plane and a $$^{10}$$B conversion layer, which converts a neutron to two charged particles. CB-KID uses the delay-line method, and allows us to reconstruct the two-dimensional neutron transmission image of a test sample with four signal readout lines. We examined the capability of high spatial and energy (wavelength) resolved neutron transmission imaging over the sensor active area of 15 $$times$$ 15 mm$$^{2}$$ for various samples, including biological and metal ones. We also demonstrated the capability for the Bragg edge transmission and an energy-resolved neutron image in which stainless-steel specimens were discriminating from other specimens.

論文

Energy-resolved neutron imaging with high spatial resolution using a superconducting delay-line kinetic inductance detector

飯澤 侑貴*; 宍戸 寛明*; 西村 和真*; Vu, TheDang*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 日高 睦夫*; et al.

Superconductor Science and Technology, 32(12), p.125009_1 - 125009_8, 2019/12

 被引用回数:13 パーセンタイル:59.07(Physics, Applied)

Neutron imaging is one of the key technologies for non-destructive transmission testing. Recent progress in the development of intensive neutron sources allows us to perform energy-resolved neutron imaging with high spatial resolution. We have been developing a neutron imager aiming at conducting high spatial and temporal resolution imaging based on a delay-line neutron detector, called the current-biased kinetic-inductance detector, with a conversion layer $$^{10}$$B. The detector allowed us to obtain a neutron transmission image with four signal readout lines. Herein, we expanded the sensor active area, and improved the spatial resolution of the detector. We examined the capability of high spatial resolution neutron imaging over the sensor active area of 15 $$times$$ 15 mm$$^{2}$$ for various samples, including biological and metal ones. We also demonstrated an energy-resolved neutron image in which stainless-steel specimens were discriminating of other specimens with the aid of the Bragg edge transmission.

論文

Inverse pole figure mapping of bulk crystalline grains in a polycrystalline steel plate by pulsed neutron Bragg-dip transmission imaging

佐藤 博隆*; 塩田 佳徳*; 諸岡 聡; 戸高 義一*; 足立 望*; 定松 直*; 及川 健一; 原田 正英; Zhang, S.*; Su, Y. H.; et al.

Journal of Applied Crystallography, 50(6), p.1601 - 1610, 2017/12

 被引用回数:17 パーセンタイル:79.13(Chemistry, Multidisciplinary)

A new mapping procedure for polycrystals using neutron Bragg-dip transmission is presented. This is expected to be useful as a new materials characterization tool which can simultaneously map the crystallographic direction of grains parallel to the incident beam. The method potentially has a higher spatial resolution than neutron diffraction imaging. As a demonstration, a Bragg-dip neutron transmission experiment was conducted at J-PARC on beamline MLF BL10 NOBORU. A large-grained Si-steel plate was used. Since this specimen included multiple grains along the neutron beam transmission path, it was a challenging task for existing methods to analyze the direction of the crystal lattice of each grain. A new data-analysis method for Bragg-dip transmission measurements was developed based on database matching. As a result, the number of grains and their crystallographic direction along the neutron transmission path have been determined.

報告書

東日本大地震のJ-PARC中性子源ステーションに対する影響

酒井 健二; 坂元 眞一; 木下 秀孝; 関 正和; 羽賀 勝洋; 粉川 広行; 涌井 隆; 直江 崇; 春日井 好己; 達本 衡輝; et al.

JAEA-Technology 2011-039, 121 Pages, 2012/03

JAEA-Technology-2011-039.pdf:10.87MB

本報告では、東日本大震災の発生時におけるJ-PARC物質・生命科学実験施設(MLF)の中性子源ステーションの挙動,被害,復旧状況を調査し、本ステーションの緊急事態に対する安全設計について検証する。大震災発生時、MLFでは、幾つかの機器で大きな揺れを検知した後、外部電源が喪失し、全循環システムが自動停止した。水素は設計通り屋外に放出され、機器異常による水銀,水素,放射性ガスの漏えいも生じなかった。一方、激しい揺れは、遮蔽体ブロックのずれ、建屋周辺の地盤沈下による外部供給配管の破断を引き起こした。この配管破断による圧縮空気の圧力低下は、水銀ターゲット台車固定装置などに影響を及ぼしたが、主要機器の大きな破損までは至らなかった。これらの結果は、本ステーションの緊急事態に対する安全設計の妥当性を実証できたとともに、幾つかの改善点も見いだされた。

論文

Influence of Great East Japan Earthquake on neutron target station in J-PARC

酒井 健二; 二川 正敏; 高田 弘; 坂元 眞一; 前川 藤夫; 木下 秀孝; 関 正和; 羽賀 勝洋; 粉川 広行; 涌井 隆; et al.

Proceedings of 20th Meeting of the International Collaboration on Advanced Neutron Sources (ICANS-20) (USB Flash Drive), 6 Pages, 2012/03

本報告では、東日本大震災の発生時におけるJ-PARC物質・生命科学実験施設(MLF)の中性子源ステーションの挙動、被害状況を調査する。大震災発生時、MLFでは幾つかの機器で大きな揺れを検知した後、外部電源が喪失し、全循環システムが自動停止した。水素は設計通り屋外に放出され、機器異常による水銀, 水素, 放射性ガスの漏えいも生じなかった。一方、激しい揺れは遮蔽体ブロックのずれ、建屋周辺の地盤沈下による外部供給配管の破断を引き起こした。この配管破断による圧縮空気の喪失は、圧空シリンダーを用いた固定装置や空気操作弁などに影響を及ぼしたが、主要機器の大きな破損までは至らなかった。これらの結果は、本ステーションの緊急事態に対する安全設計の妥当性を実証した。

論文

Increased antitumor effect of chemotherapy, using radiosensitive microcapsules containing anti-RLIP076

原田 聡*; 江原 茂*; 石井 慶造*; 佐藤 隆博; 山崎 浩道*; 松山 成男*; 神谷 富裕

JAEA-Review 2011-043, JAEA Takasaki Annual Report 2010, P. 89, 2012/01

RLIP 76 is a peptide (76 kDa) that is activated by radiation, which mediates ATP-dependent primary active efflux of organic anionic compounds (reactive oxygen species, ROS), and cationic chemotherapeutic drugs (doxorubicin, adriacin, carboplatin). Thus, the inhibition of RLIP76 by anti-RLIP 76 antibody might inhibit the efflux of ROS and chemotherapeutic reagents, and increase intratumoral concentration of chemotherapeutic reagents, which might result in increased antitumor effect. In this study, we encapsulated carboplatin (platinum based anticancer drug) and anti-RLIP 76 IgG, and their antitumor effect was tested in combination with radiation. In micro-PIXE camera imaging, unirradiated microcapsules had smooth surface and distinct liquid core. After radiation, the contour of microcapsules were made irregular and releasing of carboplatin could be observed. Then anti-RLIP-76 IgG inhibited the efflux of carboplatin from tumors.

論文

平成22年度技術士第二次試験「原子力・放射線部門」; そのポイントを探る; 選択科目の設問と解説,1

佐々木 聡; 須藤 俊幸; 原田 晃男; 栗原 良一; 山本 和喜; 土田 昇; 清水 勇; 野村 俊文

原子力eye, 57(1), p.66 - 75, 2011/01

平成22年8月8日に実施された技術士第2次試験「原子力・放射線部門」の筆記試験に関し、選択科目のうち「核燃料サイクルの技術」,「放射線利用」,「放射線防護」の問題と解答のポイントを解説した。

論文

The Kinetics of Fe and Ca for the development of radiation-induced apoptosis by micro-PIXE imaging

原田 聡*; 玉川 芳春*; 石井 慶造*; 田中 晃*; 佐藤 隆博; 松山 成男*; 山崎 浩道*; 神谷 富裕; 酒井 卓郎; 荒川 和夫; et al.

Nuclear Instruments and Methods in Physics Research B, 189(1-4), p.437 - 442, 2002/04

 被引用回数:1 パーセンタイル:12.5(Instruments & Instrumentation)

放射線誘起アポトーシスと微量元素の挙動の相互作用を詳しく調べるために、ヒト白血病細胞に$$^{60}$$Coの$$gamma$$線をインビトロで照射し、微量元素の画像化を行った。アポトーシスの頻度はTUNEL染色をした後、顕微鏡で 400 倍に拡大して得た。また、マイクロPIXE分析で細胞内の微量元素の分布の測定を行った。アポトーシスの初期段階では鉄が細胞質に集中して見られたが、アポトーシスが進行すると鉄の集積は無くなり、細胞核でCaが集積しZnが減少した。このことから、アポトーシスの進行には (1)FeやFeを含む酵素による細胞質から細胞核への信号の伝達, (2) Ca に依存する酵素による細胞核の変性と核からのZnの放出、の2つの段階が存在するようである。このような微量元素の集積はアポトーシスの新しい標識になると思われる。

口頭

2007年版JENDL高エネルギーファイル及びJENDL光核反応データファイル

深堀 智生; 国枝 賢; 千葉 敏; 原田 秀郎; 中島 宏; 森 貴正; 島川 聡司; 前川 藤夫; 渡辺 幸信*; 執行 信寛*; et al.

no journal, , 

JENDL高エネルギーファイル(JENDL/HE)及びJENDL光核反応データファイル(JENDL/PD)の最新版として、JENDL/HE-2007及びJENDL/PD-2007が公開予定である。JENDL/HE-2007にはJENDL/HE-2004から改訂及び追加をあわせて約100核種のデータが、JENDL/PD-2007には約170核種のデータが格納される予定である。

口頭

J-PARC 1MWパルス核破砕中性子源施設の完成,3; 中性子源ステーション

前川 藤夫; 高田 弘; 勅使河原 誠; 春日井 好己; 麻生 智一; 及川 健一; 原田 正英; 甲斐 哲也; 長谷川 勝一; 達本 衡輝; et al.

no journal, , 

J-PARCの1MWパルス核破砕中性子源JSNSは、平成14年度に発注を開始、その後約5年をかけて詳細設計,製作,試験検査,現地据付けを行い、平成19年7月に施設が完成した。中性子源ステーションは中性子源の中核をなし、モデレータ,反射体,極低温水素循環系,中性子ビームシャッター,遮蔽体,遠隔操作装置等で構成されている。本講演では、各機器の概要,機器設計・製作を通じて得られた主な成果、及び今後の課題について報告する。

口頭

Nondestructive detection of isotopes using nuclear resonance fluorescence with laser Compton scattering $$gamma$$-rays

早川 岳人; 静間 俊行; 羽島 良一; 菊澤 信宏; 勝村 聡一郎; 瀬谷 道夫; 原田 秀郎; 豊川 弘之*; 紀井 俊輝*; 大垣 英明

no journal, , 

数cmの厚さの鉄の板のようなシールドで遮蔽された化学物質や同位体を非破壊で測定する手法を提案している。本手法では、レーザー逆コンプトン散乱$$gamma$$線による核共鳴蛍光散乱法を用いる。厚さ1.5cmの鉄で遮蔽された$$^{208}$$Pbの同位体測定に成功した。さらに、15mmの厚さの鉄と4mmの厚さの鉛で遮蔽した化学物質であるメラミン(C$$_{3}$$H$$_{6}$$N$$_{6}$$)の検出も行った。メラミンに含まれる$$^{12}$$Cと$$^{14}$$Nの比の計測を行い、($$^{12}$$C/$$^{14}$$N)$$_{rm exp}$$=0.39$$pm$$0.12との結果を得た。実際の値は0.5であり誤差の範囲で一致した。

口頭

放射線感受性マイクロカプセルを用いた薬剤標的療法における薬剤作用長期化の試み

原田 聡*; 江原 茂*; 石井 慶造*; 山崎 浩道*; 松山 成男*; 佐藤 隆博; 神谷 富裕; 世良 耕一郎*; 斉藤 義弘*

no journal, , 

放射線照射に反応して内容を放出するマイクロカプセルを開発し、抗がん剤Carboplatinと抗がん剤排泄を抑制するRLIP76をマイクロカプセルに加えて、マウスに移植したMM48腫瘍に皮下注射を行った。20Gyの放射線照射により、76%のマイクロカプセルがCarboplatinとRLIP76を放出し、抗腫瘍効果が持続することが、大気マイクロPIXEによって確認された。

口頭

マイクロカプセルの微細化とマウスにおける体内動態

原田 聡*; 江原 茂*; 石井 慶造*; 山崎 浩道*; 松山 成男*; 佐藤 隆博; 江夏 昌志; 神谷 富裕

no journal, , 

肺,脳,脾臓,腎臓などの臓器に引っかかり塞栓症ならないように、放射線照射によって抗癌剤を放出するマイクロカプセルを微細化させた。このカプセル百万個/0.1mLをマウス(C$$_{3}$$He/J, 6週齢,オス)の尾静脈より静脈注射した。注射1時間後、肺,肝臓,腎臓,脾臓を剖出し、micro-PIXE分析(25$$times$$25$$mu$$m)の8視野中のトラップされたカプセル数をカウントした。カプセル径は、874$$pm$$12nmであり、有意にカプセルの微細がなされた。肺,肝臓,腎臓,脾臓にトラップされたカプセル数は有意に減少した。今後、静脈注射用のカプセル開発に発展させる。

口頭

Micro PIXE cameraによる放射線感受性マイクロカプセル集積度とCT吸収値との関連性

原田 聡*; 江原 茂*; 石井 慶造*; 佐藤 隆博; 江夏 昌志; 神谷 富裕

no journal, , 

放射線照射により抗癌剤を放出するマイクロカプセルを開発し、それを用いた薬剤標的療法を研究してきた。これは、腫瘍周囲皮下組織へ注入後放射線照射を照射すると抗癌剤が放出され、放射線との相乗効果により抗腫瘍効果が増強するが、薬剤限局化作用により抗癌剤の副作用が軽減するというものである。本手技を臨床応用するにあたり、腫瘍周囲への集積度を非侵襲的に測定する必要がある。今回、カプセル集積度を臨床で広く使用されているCT装置を用いて測定可能か検討するため、CT装置の測定結果とマイクロPIXEカメラによるカプセル集積度の測定結果を比較した。その結果、CT画像上でカプセルは腫瘍周囲に優位な高吸収として描出され、マイクロPIXEカメラで測定したマイクロカプセル数と強い相関を示し、腫瘍周囲のCT値からカプセル数の推定が可能であることが示唆された。

30 件中 1件目~20件目を表示