Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 51

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Incommensurate helimagnetic structure of Ba(Fe$$_{1-x}$$Sc$$_{x}$$)$$_{12}$$O$$_{19}$$ determined by single-crystal neutron diffraction

Tanaka, Seiya*; Kiyanagi, Ryoji; Ishikawa, Yoshihisa*; Amako, Yasushi*; Iiyama, Taku*; Futamura, Ryusuke*; Maruyama, Kenichi*; Utsumi, Shigenori*

Physical Review Materials (Internet), 7(1), p.014403_1 - 014403_11, 2023/01

 Times Cited Count:0 Percentile:0(Materials Science, Multidisciplinary)

Journal Articles

Radiation exposure and oxidative stress status of wild Japanese macaques in the ex-evacuation zone of the Fukushima Daiichi Nuclear Power Plant accident

Ishikawa, Ryoya*; Suzuki, Masatoshi*; Kino, Yasushi*; Endo, Satoru*; Nakajima, Hiroo*; Oka, Toshitaka; Takahashi, Atsushi*; Shimizu, Yoshinaka*; Suzuki, Toshihiko*; Shinoda, Hisashi*; et al.

KEK Proceedings 2022-2, p.61 - 66, 2022/11

The balance between oxidative stress and antioxidant activity, which is a defense mechanism against oxidative stress, was investigated in the liver and bladder of wild Japanese macaques captured in Fukushima Prefecture. No significant induction of oxidative stress by exposure to environmental radionuclides after the Fukushima nuclear accident was observed, suggesting that the stress defense mechanism of the organism is activated in some organs.

Journal Articles

Magnetic phase diagram of helimagnetic Ba(Fe$$_{1-x}$$Sc$$_{x}$$)$$_{12}$$O$$_{19}$$ (0 $$leq$$ x $$leq$$ 0.2) hexagonal ferrite

Maruyama, Kenichi*; Tanaka, Seiya*; Kiyanagi, Ryoji; Nakao, Akiko*; Moriyama, Kentaro*; Ishikawa, Yoshihisa*; Amako, Yasushi*; Iiyama, Taku*; Futamura, Ryusuke*; Utsumi, Shigenori*; et al.

Journal of Alloys and Compounds, 892, p.162125_1 - 162125_8, 2022/02

 Times Cited Count:2 Percentile:16.86(Chemistry, Physical)

Journal Articles

Flux growth and magnetic properties of helimagnetic hexagonal ferrite Ba(Fe$$_{1-x}$$Sc$$_{x}$$)$$_{12}$$O$$_{19}$$ single crystals

Utsumi, Shigenori*; Tanaka, Seiya*; Maruyama, Kenichi*; Amako, Yasushi*; Kiyanagi, Ryoji; Nakao, Akiko*; Moriyama, Kentaro*; Ishikawa, Yoshihisa*; 9 of others*

ACS Omega (Internet), 5(38), p.24890 - 24897, 2020/09

 Times Cited Count:4 Percentile:21.18(Chemistry, Multidisciplinary)

Fabricating large, high-crystalline-quality single-crystal samples of hexagonal ferrite Ba(Fe$$_{1-x}$$Sc$$_{x}$$)$$_{12}$$O$$_{19}$$ is the first important step to elucidating its helimagnetic structure and developing it for further applications. In this study, single crystals of Ba(Fe$$_{1-x}$$Sc$$_{x}$$)$$_{12}$$O$$_{19}$$ of various Sc concentrations $$x$$ were successfully grown by the spontaneous crystallization method using Na$$_{2}$$O-Fe$$_{2}$$O$$_{3}$$ flux. X-ray diffraction and elemental analysis revealed that the obtained crystals were composed of single-phase Ba(Fe$$_{1-x}$$Sc$$_{x}$$)$$_{12}$$O$$_{19}$$ of high crystalline quality. The temperature dependence of magnetization and the magnetization curves at 77 K of the $$x$$ = 0.128 crystal exhibited behavior characteristics of helimagnetism. Neutron diffraction measurements of the $$x$$ = 0.128 crystal exhibited magnetic satellite reflection peaks below 211K, proving evidence that Ba(Fe$$_{1-x}$$Sc$$_{x}$$)$$_{12}$$O$$_{19}$$ behaves as a helimagnetic material.

Journal Articles

$$omega N$$ scattering length from $$omega$$ photoproduction on the proton near the reaction threshold

Ishikawa, Takatsugu*; Fujimura, Hisako*; Fukasawa, Hiroshi*; Hashimoto, Ryo*; He, Q.*; Honda, Yuki*; Hosaka, Atsushi; Iwata, Takahiro*; Kaida, Shun*; Kasagi, Jirota*; et al.

Physical Review C, 101(5), p.052201_1 - 052201_6, 2020/05

 Times Cited Count:4 Percentile:45.12(Physics, Nuclear)

Journal Articles

Experimental study of Gamow-Teller transitions via the high-energy-resolution $$^{18}$$O($$^3$$He,$$t$$)$$^{18}$$F reaction; Identification of the low-energy "super" -Gamow-Teller state

Fujita, Hirohiko*; Fujita, Yoshitaka*; Utsuno, Yutaka; Yoshida, Kenichi*; Adachi, Tatsuya*; Algora, A.*; Csatl$'o$s, M.*; Deaven, J. M.*; Estevez-Aguado, E.*; Guess, C. J.*; et al.

Physical Review C, 100(3), p.034618_1 - 034618_13, 2019/09

AA2019-0318.pdf:1.1MB

 Times Cited Count:12 Percentile:77.09(Physics, Nuclear)

no abstracts in English

Journal Articles

Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex, 2; Neutron scattering instruments

Nakajima, Kenji; Kawakita, Yukinobu; Ito, Shinichi*; Abe, Jun*; Aizawa, Kazuya; Aoki, Hiroyuki; Endo, Hitoshi*; Fujita, Masaki*; Funakoshi, Kenichi*; Gong, W.*; et al.

Quantum Beam Science (Internet), 1(3), p.9_1 - 9_59, 2017/12

The neutron instruments suite, installed at the spallation neutron source of the Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex (J-PARC), is reviewed. MLF has 23 neutron beam ports and 21 instruments are in operation for user programs or are under commissioning. A unique and challenging instrumental suite in MLF has been realized via combination of a high-performance neutron source, optimized for neutron scattering, and unique instruments using cutting-edge technologies. All instruments are/will serve in world-leading investigations in a broad range of fields, from fundamental physics to industrial applications. In this review, overviews, characteristic features, and typical applications of the individual instruments are mentioned.

Journal Articles

Development of magnetic sensors for JT-60SA

Takechi, Manabu; Matsunaga, Go; Sakurai, Shinji; Sasajima, Tadayuki; Yagyu, Junichi; Hoshi, Ryo*; Kawamata, Yoichi; Kurihara, Kenichi; JT-60SA Team; Nishikawa, T.*; et al.

Fusion Engineering and Design, 96-97, p.985 - 988, 2015/10

 Times Cited Count:10 Percentile:64.63(Nuclear Science & Technology)

Journal Articles

Comparison between Monte Carlo simulation and measurement with a 3D polymer gel dosimeter for dose distributions in biological samples

Furuta, Takuya; Maeyama, Takuya*; Ishikawa, Kenichi*; Fukunishi, Nobuhisa*; Fukasaku, Kazuaki*; Takagi, Shu*; Noda, Shigeho*; Himeno, Ryutaro*; Hayashi, Shinichiro*

Physics in Medicine & Biology, 60(16), p.6531 - 6546, 2015/08

 Times Cited Count:18 Percentile:62.62(Engineering, Biomedical)

Low reproducibility of dose distribution in inhomogeneous regions such as soft matter near bones is known with the simple dose analysis currently adopted in treatment planning of particle cancer therapy. Therefore a treatment planning system based on Monte Carlo simulation having better accuracy is highly desired. In order to assess the simulation accuracy of a Monte Carlo simulation code in situations closely related to medical application, we performed a comparison of dose distribution in a biological sample obtained by experiment and that by simulation. In particular, we irradiate a carbon beam on a biological sample composed of fresh chicken meat and bones, with a PAGAT gel dosimeter placed behind it, and compare the complex dose distribution in the gel dosimeter created by the beam passing through the inhomogeneous sample. Monte Carlo simulation using PHITS code was conducted by reconstructing the biological sample from its computed tomography images. The simulation accurately reproduced the experimental distal edge structure of the dose distribution with an accuracy under about 2 mm.

Journal Articles

Parallel computing with Particle and Heavy Ion Transport code System (PHITS)

Furuta, Takuya; Sato, Tatsuhiko; Ogawa, Tatsuhiko; Niita, Koji*; Ishikawa, Kenichi*; Noda, Shigeho*; Takagi, Shu*; Maeyama, Takuya*; Fukunishi, Nobuhisa*; Fukasaku, Kazuaki*; et al.

Proceedings of Joint International Conference on Mathematics and Computation, Supercomputing in Nuclear Applications and the Monte Carlo Method (M&C + SNA + MC 2015) (CD-ROM), 9 Pages, 2015/04

In Particle and Heavy Ion Transport code System PHITS, two parallel computing functions are prepared to reduce the computational time. One is the distributed-memory parallelization using message passing interface (MPI) and the other is the shared-memory parallelization using OpenMP directives. Each function has advantages and disadvantages, and thus, by adopting both functions in PHITS, it is possible to conduct parallel computing suited for needs of users. It is also possible to conduct the hybrid parallelization by the intra-node OpenMP parallelization and the inter-node MPI parallelization in supercomputer systems. Each parallelization functions were explained together with some application results obtained using a workstation and a supercomputer system, K computer at RIKEN.

Journal Articles

Radiological characteristics of MRI-based VIP polymer gel under carbon beam irradiation

Maeyama, Takuya*; Fukunishi, Nobuhisa*; Ishikawa, Kenichi*; Furuta, Takuya; Fukasaku, Kazuaki*; Takagi, Shu*; Noda, Shigeho*; Himeno, Ryutaro*; Fukuda, Shigekazu*

Radiation Physics and Chemistry, 107, p.7 - 11, 2015/02

 Times Cited Count:12 Percentile:70.51(Chemistry, Physical)

We study the radiological characteristics of VIP polymer gel dosimeters under carbon beam irradiation with energy of 135 and 290 AMeV. To evaluate dose response of VIP polymer gels, the transverse relaxation rate R2 of the dosimeters measured by magnetic resonance imaging (MRI) as a function of linear energy transfer (LET), rather than penetration depth, as is usually done in previous reports. LET is evaluated by use of the particle transport simulation code PHITS. Our results reveal that the dose response decreases with increasing dose-averaged LET and that the response-LET relation also varies with incident carbon beam energy. The latter can be explained by taking into account the contribution from fragmentation products. Furthermore, as an application of the evaluated response-LET relation, we compare the measured and simulated R2 distribution in a VIP gel formed by heterogeneous irradiation and obtain agreement in overall distribution and range within an accuracy of 5% and 1-2 mm, respectively.

Journal Articles

Shape elongation of embedded Zn nanoparticles induced by swift heavy ion irradiation; A SAXS study

Amekura, Hiroshi*; Kono, Kenichiro*; Okubo, Nariaki; Ishikawa, Norito

Physica Status Solidi (B), 252(1), p.165 - 169, 2015/01

 Times Cited Count:10 Percentile:42.11(Physics, Condensed Matter)

Zinc nanoparticles (NPs) of 10 nm in diameter were irradiated with 200 MeV Xe$$^{14+}$$ ions with various fluences. The shape elongation of the NPs and the mean inter-particle (IP) distance were evaluated by small angle X-ray scattering (SAXS) in the transmission configuration using synchrotron X-ray of 18 keV. The azimuth angle dependence of SAXS signal, which was isotropic for unirradiated state, changed to anisotropic. It indicated that the NPs collectively deformed from spheres to spheroids.

Journal Articles

Front line of radiation biology; Simulation studies of radiation damage to DNA and its repair

Yokoya, Akinari; Takasu, Masako*; Ishikawa, Kenichi*

Nihon Genshiryoku Gakkai-Shi ATOMO$$Sigma$$, 56(2), p.81 - 85, 2014/02

no abstracts in English

Journal Articles

Defect formation and accumulation in CeO$$_{2}$$ irradiated with swift heavy ions

Yasuda, Kazuhiro*; Eto, Motoki*; Sawada, Kenichi*; Yamamoto, Tomokazu*; Yasunaga, Kazufumi*; Matsumura, Sho*; Ishikawa, Norito

Nuclear Instruments and Methods in Physics Research B, 314, p.185 - 190, 2013/11

 Times Cited Count:34 Percentile:92.6(Instruments & Instrumentation)

We have investigated microstructure evolution in CeO$$_{2}$$ irradiated with 210 MeV Xe ions by using transmission electron microscopy to gain the fundamental knowledge on radiation damage induced by fission fragments in nuclear fuel and transmutation target.

Journal Articles

Sagittal focusing of synchrotron radiation X-rays using a winged crystal

Nisawa, Atsushi*; Yoneda, Yasuhiro; Ueno, Go*; Murakami, Hironori*; Okajima, Yuka*; Yamamoto, Kenichiro*; Semba, Yasunori*; Uesugi, Kentaro*; Tanaka, Yoshihito*; Yamamoto, Masaki*; et al.

Journal of Synchrotron Radiation, 20(2), p.219 - 225, 2013/03

 Times Cited Count:12 Percentile:54.28(Instruments & Instrumentation)

A Si(111) winged crystal has been designed to minimize anticlastic bending and improve sagittal focusing efficiency. The crystal was thin with wide stiffening wings. The length-to-width ratio of the crystal was optimized by finite element analysis, and the optimal value was larger than the "golden value". The analysis showed that the slope error owing to anticlastic bending is less than the Darwin width. The X-rays were focused two-dimensionally using the crystal and a tangentially bent mirror. The observed profiles of the focal spot agreed well with the results of a ray-tracing calculation in the energy range from 8 to 17.5 keV. X-ray diffraction measurements with a high signal-to-noise ratio using this focusing system were demonstrated for a small protein crystal.

JAEA Reports

Plan and reports of coupled irradiation (JRR-3 and JOYO of research reactors) and hot facilities work (WASTEF, JMTR-HL, MMF and FMF); R&D project on irradiation damage management technology for structural materials of long-life nuclear plant

Matsui, Yoshinori; Takahashi, Hiroyuki; Yamamoto, Masaya; Nakata, Masahito; Yoshitake, Tsunemitsu; Abe, Kazuyuki; Yoshikawa, Katsunori; Iwamatsu, Shigemi; Ishikawa, Kazuyoshi; Kikuchi, Taiji; et al.

JAEA-Technology 2009-072, 144 Pages, 2010/03

JAEA-Technology-2009-072.pdf:45.01MB

"R&D Project on Irradiation Damage Management Technology for Structural Materials of Long-life Nuclear Plant" was carried out from FY2006 in a fund of a trust enterprise of the Ministry of Education, Culture, Sports, Science and Technology. The coupled irradiations or single irradiation by JOYO fast reactor and JRR-3 thermal reactor were performed for about two years. The irradiation specimens are very important materials to establish of "Evaluation of Irradiation Damage Indicator" in this research. For the acquisition of the examination specimens irradiated by the JOYO and JRR-3, we summarized about the overall plan, the work process and the results for the study to utilize these reactors and some facilities of hot laboratory (WASTEF, JMTR-HL, MMF and FMF) of the Oarai Research-and-Development Center and the Nuclear Science Research Institute in the Japan Atomic Energy Agency.

JAEA Reports

Replacement technology for front acrylic panels of a large-sized glove box using bag-in / bag-out method

Sakuraba, Naotoshi; Numata, Masami; Komiya, Tomokazu; Ichise, Kenichi; Nishi, Masahiro; Tomita, Takeshi; Usami, Koji; Endo, Shinya; Miyata, Seiichi; Kurosawa, Tatsuya; et al.

JAEA-Technology 2009-071, 34 Pages, 2010/03

JAEA-Technology-2009-071.pdf:21.07MB

As a part of maintenance technology of a large-sized glove box for handling of TRU nuclides, we developed replacement technology for front acrylic panels using the bag-in/bag-out method and applied this technology to replace the deteriorated front acrylic panels at Waste Safety Testing Facility (WASTEF) in Nuclear Science Research Institute of Japan Atomic Energy Agency (JAEA). As a consequence, we could safely replace the front acrylic panels under the condition of continuous negative pressure only with partial decontamination of the glove box. We also demonstrated that the present technology is highly effective in points of safety, workability and cost as compared to the usual replacement technology for front acrylic panels of a glove box, where workers in an air-line suit replace directly the front acrylic panels in a green house.

JAEA Reports

Probabilistic safety assessment on experimental fast reactor Joyo; Level1 PSA for internal events

Ishikawa, Koki; Takamatsu, Misao; Kawahara, Hirotaka; Mihara, Takatsugu; Kurisaka, Kenichi; Terano, Toshihiro; Murakami, Takanori; Noritsugi, Akihiro; Iseki, Atsushi; Saito, Takakazu; et al.

JAEA-Technology 2009-004, 140 Pages, 2009/05

JAEA-Technology-2009-004.pdf:2.0MB

Probabilistic safety assessment (PSA) has been applied to nuclear plants as a method to achieve effective safety regulation and safety management. In order to establish the PSA standard for fast breeder reactor (FBR), the FBR-PSA for internal events in rated power operation is studied by Japan Atomic Energy Agency (JAEA). The level1 PSA on the experimental fast reactor Joyo was conducted to investigate core damage probability for internal events with taking human factors effect and dependent failures into account. The result of this study shows that the core damage probability of Joyo is 5.0$$times$$10$$^{-6}$$ per reactor year (/ry) and that the core damage probability is smaller than the safety goal for existed plants (10 ry) and future plants (10$$^{-5}$$/ry) in the IAEA INSAG-12 (International Nuclear Safety Advisory Group) basic safety principle.

Journal Articles

Microdosimetric study for secondary neutrons in phantom produced by a 290 MeV/nucleon carbon beam

Endo, Satoru*; Tanaka, Kenichi*; Takada, Masashi*; Onizuka, Yoshihiko*; Miyahara, Nobuyuki*; Sato, Tatsuhiko; Ishikawa, Masayoshi*; Maeda, Naoko*; Hayabuchi, Naofumi*; Shizuma, Kiyoshi*; et al.

Medical Physics, 34(9), p.3571 - 3578, 2007/09

 Times Cited Count:7 Percentile:25.96(Radiology, Nuclear Medicine & Medical Imaging)

Absorbed doses from main charged particle beams and charged-particle fragments have been measured with high accuracy for particle therapy but there are few reports for doses from neutron components produced as fragments. This study describes measurements on neutron dose produced by carbon beam, microdosimetric distributions of secondary neutrons produced by 290 MeV/nucleon carbon beams have been measured by using a tissue equivalent proportional counter (TEPC) at the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences (NIRS). The ratios of neutrons to charged particle fragments dominated to be 11 to 89 % in the absorbed doses at the side and below the faces of the acrylic phantom (300 mm height $$times$$ 300 mm width $$times$$ 253 mm thickness).

Journal Articles

Ferritic insertion for reduction of toroidal magnetic field ripple on JT-60U

Shinohara, Koji; Sakurai, Shinji; Ishikawa, Masao; Tsuzuki, Kazuhiro*; Suzuki, Yutaka; Masaki, Kei; Naito, Osamu; Kurihara, Kenichi; Suzuki, Takahiro; Koide, Yoshihiko; et al.

Nuclear Fusion, 47(8), p.997 - 1004, 2007/08

 Times Cited Count:40 Percentile:78.43(Physics, Fluids & Plasmas)

Ferritic steel plates have been installed to improve the energetic ion confinement through reducing a toroidal magnetic field ripple. Aiming at cost-effective installation, orbit following calculations of energetic ions were performed for a design of ferritic installation on JT-60U by using the Fully three Dimensional magnetic field Orbit-Following Monte-Carlo (F3D OFMC) code. The installed ferritic steel adds the non-linear magnetic field on magnetic sensors for a plasma control and an equilibrium calculation. The code for a real-time control has been modified to take into account the magnetic field by ferritic steel. The plasma operation was successfully resumed and a real-time plasma control was successfully carried out after usual preparation processes. The heat load measurement indicates the improved confinement of energetic ions. These results are important for practical application of ferritic steel which is a leading candidate of a structural material on a demo reactor.

51 (Records 1-20 displayed on this page)