Refine your search:     
Report No.
 - 
Search Results: Records 1-6 displayed on this page of 6
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Confirmation of the availability of an analytical technique, Pu(VI) spectrophotometry for HALW; Technical Support for the Joint IAEA/Japan On-site Analytical Laboratory at the Rokkasho Reprocessing Plant (JASPAS JU-01-01)

Kitao, Takahiko; Sato, Soichi; Kuno, Takehiko; Keiji, Yamada,; Watahiki, Masaru; Kamata, Masayuki

JNC TN8410 2003-014, 29 Pages, 2003/11

JNC-TN8410-2003-014.pdf:1.82MB

The Agency requested the Tokai Reprocessing Plant(TRP) to confirm the applicability of three kinds of analytical procedure for Pu(VI) spectrophotometry in On-Site Analytical Laboratory (OSL) at Rokkasho, in order to obtain accurate plutonium(Pu) concentration in High Active Liquid Waste (HALW). Three analytical procedures, (1) Calibration method, (2) Nd internal standard method and (3) Reduction method, were tested. The measurement sample was prepared by adding the known amount of plutonium in the actual HALW after removing original Pu by solid extraction. We measured the Pu concentration in the sample by three methods and calculated the accuracy and precision. The results of each method are summarized as follows:(1) Calibration method Plutonium concentration calculated by the calibration method agreed with that by adjusted concentration. (2) Nd internal standard method Accurate results were obtained by this method. The error of pretreatment, especially dilution, has not influenced on the Pu measurements. (3) Reduction method The measured Pu concentrations were higher than those by adjusted. From the comparison with these results, the calibration method is the most simple and rapid in the three methods. Analysis time was within 1 hour including sample preparation. The detection limit, with the calibration method, was 1.3 mgPu/L in the actual HALW measurements.

JAEA Reports

None

Asakura, Yoshiro*; Miyahara, Kenji; *; Masui, J.*; Kondo, Isao*; *; *; Kamata, Masayuki

PNC TN852 81-18, 266 Pages, 1981/05

PNC-TN852-81-18.pdf:6.24MB

None

JAEA Reports

None

Miyahara, Kenji; Asakura, Yoshiro*; *; Masui, J.*; Kondo, Isao*; *; Kamata, Masayuki; *

PNC TN852 81-15, 46 Pages, 1981/04

PNC-TN852-81-15.pdf:2.23MB

None

JAEA Reports

None

Kaya, Akira; ; Wada, Yukio; Takahashi, Mitsuru*; *; *; Kamata, Masayuki; Wada, Tsutomu*

PNC TN841 79-47, 154 Pages, 1979/08

PNC-TN841-79-47.pdf:4.32MB

no abstracts in English

JAEA Reports

None

*; Wada, Yukio; Kamata, Masayuki; Wada, Tsutomu*; *; Tsuboya, Takao*

PNC TN841 77-27, 22 Pages, 1977/06

PNC-TN841-77-27.pdf:0.51MB

no abstracts in English

JAEA Reports

None

Tsuboya, Takao*; Kamata, Masayuki; Wada, Yukio; Masui, J.*; *; Wada, Tsutomu*; ; *

PNC TN851 76-01, 42 Pages, 1976/01

PNC-TN851-76-01.pdf:1.26MB

None

6 (Records 1-6 displayed on this page)
  • 1