検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 7 件中 1件目~7件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Neutron reflectometry analysis of condensed water layer formation at a solid interface of epoxy resins under high humidity

Liu, Y.*; 宮田 登*; 宮崎 司*; 春藤 淳臣*; 川口 大輔*; 田中 敬二*; 青木 裕之

Langmuir, 39(29), p.10154 - 10162, 2023/06

 被引用回数:1 パーセンタイル:52.07(Chemistry, Multidisciplinary)

Water absorbed by epoxy resins from a humid atmosphere considerably influences their structure and properties. Examining the effects of absorbed water on epoxy resins at their interfaces with solid substrates is crucial because of their adhesive applications in various fields. The spatial distribution of absorbed water in epoxy resin thin films under high humidity was investigated in this study by neutron reflectometry. Water molecules were found to accumulate at the SiO$$_{2}$$/epoxy resin interface after exposure at a relative humidity of 85% for 8 h. The formation of an ca.1 nm-thick condensed water layer was observed, and the thickness of this layer varied with curing conditions of epoxy systems. Furthermore, the water accumulation at the interface was noted to be affected by high-temperature and high-humidity environments. The formation of the condensed water layer is presumed to be related to the features of the polymer layer near the interface. The construction of the interface layer of epoxy resin would be affected by the interface constraint effect on the cross-linked polymer chain during the curing reaction. This study provides essential information for understanding the factors influencing the accumulation of water at the interface in epoxy resins. In the practical application, the process of improving the construction of epoxy resin near the interface would be a reasonable solution to resist the water accumulation in the interface.

論文

Kinetics of the interfacial curing reaction for an epoxy-amine mixture

Yamaguchi, Ko*; 川口 大輔*; 宮田 登*; 宮崎 司*; 青木 裕之; Yamamoto, Satoru*; 田中 敬二*

Physical Chemistry Chemical Physics, 24(36), p.21578 - 21582, 2022/09

 被引用回数:5 パーセンタイル:70.33(Chemistry, Physical)

A better understanding of the chemical reaction between epoxy and amine compounds at a solid interface is crucial for the design and fabrication of materials with appropriate adhesive strength. Here, we examined the curing reaction kinetics of epoxy phenol novolac and 4,4'-diaminodiphenyl sulfone at the outermost interface using sum-frequency generation spectroscopy, and X-ray and neutron reflectivity in conjunction with a full atomistic molecular dynamics simulation. The reaction rate constant was much larger at the quartz interface than in the bulk. While the apparent activation energy at the quartz interface obtained from an Arrhenius plot was almost identical to the bulk value, the frequency factor at the quartz interface was greater than that in the bulk. These results could be explained in terms of the densification and orientation of reactants at the interface, facilitating the encounter of the reactants present.

論文

Detailed structural study on the poly(vinyl alcohol) adsorption layers on a Si substrate with solvent vapor-induced swelling

宮崎 司*; 宮田 登*; 吉田 鉄生*; 有馬 寛*; 津村 佳弘*; 鳥飼 直也*; 青木 裕之; 山本 勝宏*; 金谷 利治*; 川口 大輔*; et al.

Langmuir, 36(13), p.3415 - 3424, 2020/04

 被引用回数:14 パーセンタイル:58.64(Chemistry, Multidisciplinary)

We investigated in detail the structures in the poly(vinyl alcohol) (PVA) adsorption layers on a Si substrate, which remained on the substrate after immersing the relatively thick 30 - 50 nm films in hot water, by neutron reflectometry under humid conditions. For the PVA with a degree of saponification exceeding 98 mol %, the adsorption layer exhibits a three-layered structure in the thickness direction. The bottom layer is considered to be the so-called inner adsorption layer that is not fully swollen with water vapor. This may be because the polymer chains in the inner adsorption layer are strongly constrained onto the substrate, which inhibits water vapor penetration. The polymer chains in this layer have many contact points to the substrate via the hydrogen bonding between the hydroxyl groups in the polymer chain and the silanol groups on the surface of the Si substrate and consequently exhibit extremely slow dynamics. Therefore, it is inferred that the bottom layer is fully amorphous. Furthermore, we consider the middle layer to be somewhat amorphous because parts of the molecular chains are pinned below the interface between the middle and bottom layers. The molecular chains in the top layer become more mobile and ordered, owing to the large distance from the strongly constrained bottom layer; therefore, they exhibit a much lower degree of swelling compared to the middle amorphous layer. Meanwhile, for the PVA with a much lower degree of saponification, the adsorption layer structure consists of the two-layers. The bottom layer forms the inner adsorption layer that moderately swells with water vapor because the polymer chains have few contact points to the substrate. The molecular chains in the middle layer, therefore, are somewhat crystallizable because of this weak constraint.

論文

Elucidation of a heterogeneous layered structure in the thickness direction of poly(vinyl alcohol) films with solvent vapor-induced swelling

宮崎 司*; 宮田 登*; 浅田 光則*; 津村 佳弘*; 鳥飼 直也*; 青木 裕之; 山本 勝宏*; 金谷 利治*; 川口 大輔*; 田中 敬二*

Langmuir, 35(34), p.11099 - 11107, 2019/08

 被引用回数:22 パーセンタイル:67.64(Chemistry, Multidisciplinary)

We investigated the swelling behaviors of poly(vinyl alcohol) (PVA) films deposited on Si wafers with water vapor, which is a good solvent for PVA for elucidating structural and dynamical heterogeneities in the film thickness direction. Using deuterated water vapor, structural and dynamical differences in the thickness direction can be detected easily as different degrees of swelling in the thickness direction by neutron reflectivity. Consequently, the PVA film with a degree of saponification exceeding 98 mol % exhibits a three-layered structure in the thickness direction. It is considered that an adsorption layer consisting of molecular chains that are strongly adsorbed onto the solid substrate is formed at the interface with the substrate, which is not swollen with water vapor compared with the bulk-like layer above it. The adsorption layer is considered to exhibit significantly slower dynamics than the bulk. Furthermore, a surface layer that swells excessively compared with the underneath bulk-like layer is found. This excess swelling of the surface layer may be related to a higher mobility of the molecular chains or lower crystallinity at the surface region compared to the underneath bulk-like layer. Meanwhile, for the PVA film with a much lower degree of saponification, a thin layer with a slightly lower degree of swelling than the bulk-like layer above it can be detected at the interface between the film and substrate only under a high humidity condition. This layer is considered to be the adsorption layer composed of molecular chains loosely adsorbed onto the Si substrate.

報告書

重力場を活用した新概念FBRの成立性に関する研究(II)

山岡 信夫*; 斉藤 正樹*; 宮崎 慶次*

PNC TJ9605 92-002, 128 Pages, 1991/03

PNC-TJ9605-92-002.pdf:2.73MB

高速増殖炉のエネルギー輸送・変換系を簡素化すると同時に、安全姓の向上を図ることを目的として、二相流自然循環と液体金属MHD発電を組み合わせた新しい概念の自律型エネルギー変換システムの成立性に関する基礎研究を実施した。まず、最初、本システムのサイクル解析を実施した。基本的な作動流体として、水と低融点合金、水銀とスズの組合せを選び、二相流上昇部入口ボイド率、気液スリップ比、そして各コンポーネントの効率をパラメータとし、さらにシステムの最高温度を変化させて感度解析を行った。本解析の結果、本システムは従来の蒸気タービンサイクルに十分競合できるだけのサイクル効率が得られる可能性が高いことがわかった。しかし、サイクル効率は、気液分離器、再生熱交換器、及び熱力学的作動流体用循環ポンプの各効率にはあまり影響を受けないが、気液スリップ比と単相流下降部に設置する発電器効率に大きく影響を受け、気液スリップ比が低い値になるような二相流の心要があることがわかった。サイクル解析の結果、サイクル効率は循環する二相流の気液スリップ比に大きく影響を受けるため、次に、特に二相流上昇部における気液スリップ比に注目した、液体金属二相流自然循環特性を調べる基礎実験を実施した。作動流体としてウッズメタル(融点70度C、密度約9・5g/cm/SUP3)と窒素ガスを用い、二相流上昇部高さ約2mの試験装置で二相流自然循環の基本的な循環特性を調べた。本実験結果により、以下に示す結果を得た。(1)ボイド率が、約0.13程度までは気泡流で、気相流量の増加とともに液体循環流量は急激に増加し、気液スリップ比が比較的に小さいが、それ以降はスラッグ流に遷移しするため、気液スリップ比が増加し、液相循環流量の増加量は減る。(2)二相流自然循環におけるボイド率は、クオリティ-、フルイド数、気液密度比により以下に示す相関式で求められる。$$alpha$$=8.7(X/1-X)0.33(Fr)0.78($$rho$$1/$$rho$$g)-0.22

報告書

超伝導-電磁流体技術のFBRへの適用に関するフィージビリティ研究

秋山 守*; 宮崎 慶次*; 竹下 寿英*

PNC TJ2360 88-001, 222 Pages, 1988/03

PNC-TJ2360-88-001.pdf:6.14MB

最近の超電導技術開発の進展は、原子力分野への適用可能性を拡げており、将来のFBR開発にも、様々の適用可能性が考えられる。本研究では、初めに超電導の特徴と基盤となる技術を調べ、原子力関連分野への超電導技術導入の領域とその導入プロセスを検討した。その後、FBRへの適用分野として超電導電磁ポンプ及び液体金属MHD発電システムに注目し、基本概念と効果、今後の開発課題を明らかにした。超電導の電磁ポンプへの適用では、交流誘導式ポンプ(ALIP)、DCファラデー型ポンプ、及びフローカプラーのフィージビリティが高い。将来への課題としては、ALIPに対する交流超電体の開発、DCファラデー型ではシステム構成そのもの、フローカプラーでは強い磁場の有効な活用があり、具体的な数料検討をすすめる必要がある。超電導のMHD発電システムへの適用では、中央発電所の場合と、宇宙用発電の場合を検討した。中央発電所方式では、サイクルとして2成分2相流エリクソンサイクルが最も有望と考えられるが、現行の温度条件の制約、低温側タービンとの結合の必要性等が効率と経済性上の課題となる。宇宙用発電では、軽量小型化、高信頼度が重要視されるので、高温FBR及び超電導による利点が大いに活かせる。今後の液体金属MHD発電システム開発の課題としては、磁場端部(損失)効果の低減、熱サイクル・流体加速法の工夫、作動流体の沸騰、凝縮等の特性の把握と有効利用、等がある。電磁流体力学の応用としては、FBRの緊急冷却系、核融合Li冷却、電磁冶金、電磁推進等が考えられ、技術開発の波及効果は大きい。

報告書

原子炉安全性評価に関連する蒸気爆発現象

宮崎 慶次*; 高橋 克郎*

PNC TN951 80-02, 69 Pages, 1980/02

PNC-TN951-80-02.pdf:2.44MB

ここ数年来原子炉の安全性に関連した蒸気爆発現象の解明に,多くの研究者の努力が傾けられてきたが,いまだ充分に解明されていない。最近ではOECD/CSNI/NEAの主催により各国の研究者が協力してこの現象の解明に当っており,問題点の整理,提案されている各モデルの是非が議論されている。本著作は,蒸気爆発現象に関してよくまとめられているので邦訳したものである。

7 件中 1件目~7件目を表示
  • 1