検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 3 件中 1件目~3件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Synthesis, crystal structure, local structure, and magnetic properties of polycrystalline and single-crystalline Ce$$_2$$Pt$$_6$$Al$$_{15}$$

太田 玖吾*; 渡部 悠貴*; 芳賀 芳範; Iesari, F.*; 岡島 敏浩*; 松本 裕司*

Symmetry (Internet), 15(8), p.1488_1 - 1488_13, 2023/07

 被引用回数:1 パーセンタイル:60.94(Multidisciplinary Sciences)

Polycrystalline and single crystalline Ce$$_2$$Pt$$_6$$Al$$_{15}$$ samples were synthesized and characterized using EPMA, XRD, XAS and magnetization measurements. The valence of Ce in this compound is trivalent, in agreement with magnetic susceptibility and XAS spectra. The analysis of EXAFS spectra indicates the formation of a honeycomb lattice rather than the disordered hexagonal structure.

論文

Bayesian sparse modeling of extended X-ray absorption fine structure to determine interstitial oxygen positions in yttrium oxyhydride epitaxial thin film

熊添 博之*; 五十嵐 康彦*; Iesari, F.*; 清水 亮太*; 小松 遊矢*; 一杉 太郎*; 松村 大樹; 齋藤 寛之*; 岩満 一功*; 岡島 敏浩*; et al.

AIP Advances (Internet), 11(12), p.125013_1 - 125013_5, 2021/12

 被引用回数:2 パーセンタイル:17.05(Nanoscience & Nanotechnology)

This letter presents a Bayesian sparse modeling method to analyze extended X-ray absorption fine structure (EXAFS) data with basis functions built on two-body signals. This method allows us to evaluate regression coefficients proportional to the radial distribution functions of the respective elements and their errors and is very effective for analysis of EXAFS with weak absorption intensity and severe signal-to-noise ratio. As an application example, we used it to analyze EXAFS of an yttrium oxyhydride (YO$$_{x}$$H$$_{y}$$) epitaxial thin film. This EXAFS data shows weak absorption intensity due to the small amount of X-ray absorption in the thin film sample. However, this approach revealed that the radial distance ratio of the second neighbor yttrium to the first neighbor oxygen coincides with that of a tetrahedral configuration. This result demonstrates that the interstitial oxygen position is tetrahedral in the YO$$_{x}$$H$$_{y}$$ thin film.

論文

Plasma diagnostics in JFT-2M

河西 敏*; 神谷 健作; 篠原 孝司; 川島 寿人; 小川 宏明; 上原 和也; 三浦 幸俊; 岡野 文範; 鈴木 貞明; 星野 克道; et al.

Fusion Science and Technology, 49(2), p.225 - 240, 2006/02

 被引用回数:3 パーセンタイル:24.08(Nuclear Science & Technology)

約30台の計測装置から構成されているJFT-2Mの計測診断システムは、プラズマ生成,制御,平衡,安定性,閉込め,NBIやRF(LH, ICRF, ECH)による加熱,RFによる電流駆動の研究に使用されてきた。このうち、運動シュタルク効果を利用した偏光計,荷電交換反応分光器,重イオンビームプローブ,飛行時間測定法による中性粒子測定器等は、Hモード,高リサイクリング定常(HRS)Hモードの閉込め改善機構の解明や運転領域の探求に貢献した。赤外テレビカメラ,損失イオンプローブは、リップル損失粒子による壁への熱負荷,主プラズマからの損失するイオンに関する研究でそれぞれ重要な役割を果たした。この論文は、これらの計測機器についてレビューしたものである。

3 件中 1件目~3件目を表示
  • 1