Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 154

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Non-destructive elemental analysis of lunar meteorites using a negative muon beam

Chiu, I.-H. ; Terada, Kentaro*; Osawa, Takahito; Park, C.*; Takeshita, Soshi*; Miyake, Yasuhiro*; Ninomiya, Kazuhiko*

Meteoritics & Planetary Science, 58(9), p.1333 - 1344, 2023/09

 Times Cited Count:0 Percentile:0.01(Geochemistry & Geophysics)

JAEA Reports

Differential pressure rise event for filters of HTTR primary helium gas circulators, 1; Investigation of differential pressure rise event

Nemoto, Takahiro; Arakawa, Ryoki; Kawakami, Satoru; Nagasumi, Satoru; Yokoyama, Keisuke; Watanabe, Masashi; Onishi, Takashi; Kawamoto, Taiki; Furusawa, Takayuki; Inoi, Hiroyuki; et al.

JAEA-Technology 2023-005, 33 Pages, 2023/05

JAEA-Technology-2023-005.pdf:5.25MB

During shut down of the HTTR (High Temperature engineering Test Reactor) RS-14 cycle, an increasing trend of filter differential pressure for the helium gas circulator was observed. In order to investigate this phenomenon, the blower of the primary helium purification system was disassembled and inspected. As a result, it is clear that the silicon oil mist entered into the primary coolant due to the deterioration of the charcoal filter performance. The replacement and further investigation of the filter are planning to prevent the reoccurrence of the same phenomenon in the future.

Journal Articles

Development of nondestructive elemental analysis system for Hayabusa2 samples using muonic X-rays

Osawa, Takahito; Nagasawa, Shunsaku*; Ninomiya, Kazuhiko*; Takahashi, Tadayuki*; Nakamura, Tomoki*; Wada, Taiga*; Taniguchi, Akihiro*; Umegaki, Izumi*; Kubo, Kenya*; Terada, Kentaro*; et al.

ACS Earth and Space Chemistry (Internet), 7(4), p.699 - 711, 2023/04

 Times Cited Count:4 Percentile:93.95(Chemistry, Multidisciplinary)

The concentrations of carbon and other major elements in asteroid samples provide very important information on the birth of life on the Earth and the solar-system evolution. Elemental analysis using muonic X-rays is one of the best analytical methods to determine the elemental composition of solid materials, and notably, is the only method to determine the concentration of light elements in bulk samples in a non-destructive manner. We developed a new analysis system using muonic X-rays to measure the concentrations of carbon and other major elements in precious and expectedly tiny samples recovered from the asteroid Ryugu by spacecraft Hayabusa2. Here we report the development process of the system in 4 stages and their system configurations, The analysis system is composed of a stainless-steel analysis chamber, an acrylic glove box for manipulating asteroid samples in a clean environment, and Ge semiconductor detectors arranged to surround the analysis chamber. The performance of the analysis system, including the background level, which is crucial for the measurement, was greatly improved from the first stage to the later ones. Our feasibility study showed that the latest model of our muonic X-ray analysis system is capable of determining the carbon concentration in Hayabusa2's sample model with an uncertainty of less than 10 percent in a 6-day measurement.

Journal Articles

Non-destructive elemental analysis of lunar materials with negative muon beam at J-PARC

Chiu, I.-H. ; Terada, Kentaro*; Osawa, Takahito; Park, C.*; Takeshita, Soshi*; Miyake, Yasuhiro*; Ninomiya, Kazuhiko*

Journal of Physics; Conference Series, 2462, p.012004_1 - 012004_6, 2023/03

 Times Cited Count:0 Percentile:0.2(Physics, Applied)

In the last decade, non-destructive elemental analysis using negative muon beams advanced significantly. This method can be used to determine the elemental composition of bulk materials without causing damage. In this study, we performed a negative muon irradiation experiment for a Northwest Africa 482 lunar meteorite (NWA482), which was installed in a stainless steel analysis chamber. The analysis chamber was filled with helium gas to suppress the background signals caused by air-scattering muons. The muonic X-rays from Al, Fe, Ca, Mg, Si, and O in the samples were detected using six high-purity germanium semiconductor detectors arranged around the analysis chamber. To correct the X-ray self-absorption effect of the samples, a Monte-Carlo simulation using Geant4 toolkit was used. Based on the quantitative analysis for muonic X-ray measurement with the correction application from the simulation, we successfully investigated the analytical sensitivity of each element in meteorites based on the NWA482 data.

Journal Articles

Improving the safety of the high temperature gas-cooled reactor "HTTR" based on Japan's new regulatory requirements

Hamamoto, Shimpei; Shimizu, Atsushi; Inoi, Hiroyuki; Tochio, Daisuke; Homma, Fumitaka; Sawahata, Hiroaki; Sekita, Kenji; Watanabe, Shuji; Furusawa, Takayuki; Iigaki, Kazuhiko; et al.

Nuclear Engineering and Design, 388, p.111642_1 - 111642_11, 2022/03

 Times Cited Count:2 Percentile:53.91(Nuclear Science & Technology)

Following the Fukushima Daiichi Nuclear Power Plant accident in 2011, the Japan Atomic Energy Agency adapted High-Temperature engineering Test Reactor (HTTR) to meet the new regulatory requirements that began in December 2013. The safety and seismic classifications of the existing structures, systems, and components were discussed to reflect insights regarding High Temperature Gas-cooled Reactors (HTGRs) that were acquired through various HTTR safety tests. Structures, systems, and components that are subject to protection have been defined, and countermeasures to manage internal and external hazards that affect safety functions have been strengthened. Additionally, measures are in place to control accidents that may cause large amounts of radioactive material to be released, as a beyond design based accident. The Nuclear Regulatory Commission rigorously and appropriately reviewed this approach for compliance with the new regulatory requirements. After nine amendments, the application to modify the HTTR's installation license that was submitted in November 2014 was approved in June 2020. This response shows that facilities can reasonably be designed to meet the enhanced regulatory requirements, if they reflect the characteristics of HTGRs. We believe that we have established a reference for future development of HTGR.

Journal Articles

Dynamical response of transition-edge sensor microcalorimeters to a pulsed charged-particle beam

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I.-H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

IEEE Transactions on Applied Superconductivity, 31(5), p.2101704_1 - 2101704_4, 2021/08

 Times Cited Count:1 Percentile:11.15(Engineering, Electrical & Electronic)

A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.

Journal Articles

Deexcitation dynamics of muonic atoms revealed by high-precision spectroscopy of electronic $$K$$ X rays

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I. H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

Physical Review Letters, 127(5), p.053001_1 - 053001_7, 2021/07

 Times Cited Count:13 Percentile:79.44(Physics, Multidisciplinary)

We observed electronic $$K$$X rays emitted from muonic iron atoms using a superconducting transition-edge-type sensor microcalorimeter. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic $$K$$$$alpha$$ and $$K$$$$beta$$ X rays together with the hypersatellite $$K$$$$alpha$$ X rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the $$L$$-shell electrons, accompanied by electron side-feeding. Assisted by a simulation, this data clearly reveals the electronic $$K$$- and $$L$$-shell hole production and their temporal evolution during the muon cascade process.

JAEA Reports

Manufacture of substitutive assemblies for MONJU reactor decommissioning

Sakakibara, Hiroshi; Aoki, Nobuhiro; Muto, Masahiro; Otabe, Jun; Takahashi, Kenji*; Fujita, Naoyuki*; Hiyama, Kazuhiko*; Suzuki, Hirokazu*; Kamogawa, Toshiyuki*; Yokosuka, Toru*; et al.

JAEA-Technology 2020-020, 73 Pages, 2021/03

JAEA-Technology-2020-020.pdf:8.26MB

The decommissioning is currently in progress at the prototype fast breeder reactor Monju. Fuel assemblies will be taken out of its core for the first step of the great task. Fuel assemblies stand on their own spike plugged into a socket on the core support plate and support with adjacent assemblies through their housing pads each other, resulting in steady core structure. For this reason, some substitutive assemblies are necessary for the purpose of discharging the fuel assemblies of the core. Monju side commissioned, therefore, Plutonium Fuel Development Center to manufacture the substitutive assemblies and the Center accepted it. This report gives descriptions of design, manufacture, and shipment in regard to the substitutive assemblies.

Journal Articles

Establishment of numerical model to investigate heat transfer and flow characteristics by using scale model of vessel cooling system for HTTR

Takada, Shoji; Ngarayana, I. W.*; Nakatsuru, Yukihiro*; Terada, Atsuhiko; Murakami, Kenta*; Sawa, Kazuhiko*

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 13 Pages, 2019/05

In the loss of core cooling test using HTTR, a technical issue is to improve prediction accuracy of temperature distribution of components in vessel cooling system (VCS). An establishment of reasonable 2D model was started by using numerical code FLUENT, which was validated using the test data by 1/6 scale model of VCS for HTTR. The pressure vessel (PV) temperature was set around 200$$^{circ}$$C attributed to relatively high ratio of natural convection heat transfer around 20% in total heat removal, which is useful for code to experiment benchmark to improve prediction accuracy. It is necessary to confirm heat transfer flow characteristics around the top of PV which is heated up by natural convection flow which was considered to be affected by separation, re-adhesion and transition flow. The k-$$omega$$-SST model was selected for turbulent calculation attributed to predict the effects mentioned above adequately. The numerical results using the k-$$omega$$-SST model reproduced the temperature distribution of PV especially the top region which is considered to be affected by separation, re-adhesion and transition flow in contract to that using k-$$varepsilon$$ model which does not account the effects.

Journal Articles

Comprehensive seismic evaluation of HTTR against the 2011 off the Pacific coast of Tohoku Earthquake

Ono, Masato; Iigaki, Kazuhiko; Sawahata, Hiroaki; Shimazaki, Yosuke; Shimizu, Atsushi; Inoi, Hiroyuki; Kondo, Toshinari; Kojima, Keidai; Takada, Shoji; Sawa, Kazuhiro

Journal of Nuclear Engineering and Radiation Science, 4(2), p.020906_1 - 020906_8, 2018/04

On March 11th, 2011, the 2011 off the Pacific coast of Tohoku Earthquake of magnitude 9.0 occurred. When the great earthquake occurred, the High Temperature Engineering Test Reactor (HTTR) had been stopped under the periodic inspection and maintenance of equipment and instruments. A comprehensive integrity evaluation was carried out for the HTTR facility because the maximum seismic acceleration observed at the HTTR exceeded the maximum value of design basis earthquake. The concept of comprehensive integrity evaluation is divided into two parts. One is the "visual inspection of equipment and instruments". The other is the "seismic response analysis" for the building structure, equipment and instruments using the observed earthquake. All equipment and instruments related to operation were inspected in the basic inspection. The integrity of the facilities was confirmed by comparing the inspection results or the numerical results with their evaluation criteria. As the results of inspection of equipment and instruments associated with the seismic response analysis, it was judged that there was no problem for operation of the reactor, because there was no damage and performance deterioration. The integrity of HTTR was also supported by the several operations without reactor power in cold conditions of HTTR in 2011, 2013 and 2015. Additionally, the integrity of control rod guide blocks was also confirmed visually when three control rod guide blocks and six replaceable reflector blocks were taken out from reactor core in order to change neutron startup sources in 2015.

Journal Articles

Non-destructive elemental analysis of a carbonaceous chondrite with direct current Muon beam at MuSIC

Terada, Kentaro*; Sato, Akira*; Ninomiya, Kazuhiko*; Kawashima, Yoshitaka*; Shimomura, Koichiro*; Yoshida, Go*; Kawai, Yosuke*; Osawa, Takahito; Tachibana, Shogo*

Scientific Reports (Internet), 7(1), p.15478_1 - 15478_6, 2017/11

AA2017-0455.pdf:1.15MB

 Times Cited Count:21 Percentile:68.68(Multidisciplinary Sciences)

Electron- or X-ray-induced characteristic X-ray analysis has been widely used to determine chemical compositions of materials in vast research fields. In recent years, analysis of characteristic X-rays from muonic atoms, in which a muon is captured, has attracted attention because both a muon beam and a muon-induced characteristic X-ray have high transmission abilities. Here we report the first non-destructive elemental analysis of a carbonaceous chondrite using one of the world-leading intense direct current muon beam source (MuSIC; MUon Science Innovative Channel). We successfully detected characteristic muonic X-rays of Mg, Si, Fe, O, S and C from Jbilet Winselwan CM chondrite, of which carbon content is about 2 wt percent, and the obtained elemental abundance pattern was consistent with that of CM chondrites.

Journal Articles

Investigation of countermeasure against local temperature rise in vessel cooling system in loss of core cooling test without nuclear heating

Ono, Masato; Shimizu, Atsushi; Kondo, Makoto; Shimazaki, Yosuke; Shinohara, Masanori; Tochio, Daisuke; Iigaki, Kazuhiko; Nakagawa, Shigeaki; Takada, Shoji; Sawa, Kazuhiro

Journal of Nuclear Engineering and Radiation Science, 2(4), p.044502_1 - 044502_4, 2016/10

In the loss of forced core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of reactor core is stopped without inserting control rods into the core and cooling by Vessel Cooling System (VCS) to verify safety evaluation codes to investigate the inherent safety of HTGR be secured by natural phenomena to make it possible to design a severe accident free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water cooling tube by thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from gas circulators with stopping water flow in the VCS, the local higher temperature position was specified although the temperature was sufficiently lower than the maximum allowable working temperature, and natural circulation of water had insufficient cooling effect on the temperature of water cooling tube below 1$$^{circ}$$C. Then, a new safe and secured procedure for the loss of forced core cooling test was established, which will be carried out soon after the restart of HTTR.

Journal Articles

Visualization in response analyses for a nuclear power plant

Nakajima, Norihiro; Nishida, Akemi; Miyamura, Hiroko; Iigaki, Kazuhiko; Sawa, Kazuhiro

Kashika Joho Gakkai-Shi (USB Flash Drive), 36(Suppl.2), 4 Pages, 2016/10

Since nuclear power plants have dimensions approximately 100m$$^{3}$$ and their structures are an assembly made up of over 10 million components, it is not convenient to experimentally analyze its behavior under strong loads of earthquakes, due to the complexity and hugeness of plants. The proposed system performs numerical simulations to evaluate the behaviors of an assembly like a nuclear facility. The paper discusses how to carry out visual analysis for assembly such as nuclear power plants. In a result discussion, a numerical experiment was carried out with a numerical model of High Temperature engineering Test Reactor of Japan Atomic Energy Agency and its result was compared with observed data. A good corresponding among them was obtained as a structural analysis of an assembly by using visualization. As a conclusion, a visual analytics methodology for assembly is discussed.

Journal Articles

Confirmation of seismic integrity of HTTR against 2011 Great East Japan Earthquake

Ono, Masato; Iigaki, Kazuhiko; Shimazaki, Yosuke; Shimizu, Atsushi; Inoi, Hiroyuki; Tochio, Daisuke; Hamamoto, Shimpei; Nishihara, Tetsuo; Takada, Shoji; Sawa, Kazuhiro; et al.

Proceedings of 24th International Conference on Nuclear Engineering (ICONE-24) (DVD-ROM), 12 Pages, 2016/06

On March 11th, 2011, the Great East Japan Earthquake of magnitude 9.0 occurred. When the great earthquake occurred, the HTTR had been stopped under the periodic inspection and maintenance of equipment and instrument. In the great earthquake, the maximum seismic acceleration observed at the HTTR exceeded the maximum value in seismic design. The visual inspection of HTTR facility was carried out for the seismic integrity conformation of HTTR. The seismic analysis was also carried out using the observed earthquake motion at HTTR site to confirm the integrity of HTTR. The concept of comprehensive integrity evaluation for the HTTR facility is divided into two parts. One is the inspection of equipment and instrument. The other is the seismic response analysis using the observed earthquake. For the basic inspections of equipment and instrument were performed for all them related to the operation of reactor. The integrity of the facilities is confirmed by comparing the inspection results or the numerical results with their evaluation criteria. As the result of inspection of equipment and instrument and seismic response analysis, it was judged that there was no problem to operate the reactor, because there was no damage and performance deterioration, which affects the reactor operation. The integrity of HTTR was also supported by the several operations without reactor power in cold conditions of HTTR in 2011, 2013 and 2015.

Journal Articles

Evaluation on seismic integrity of HTTR core components

Ono, Masato; Iigaki, Kazuhiko; Shimazaki, Yosuke; Tochio, Daisuke; Shimizu, Atsushi; Inoi, Hiroyuki; Hamamoto, Shimpei; Takada, Shoji; Sawa, Kazuhiro

Proceedings of International Topical Meeting on Research Reactor Fuel Management and Meeting of the International Group on Reactor Research (RRFM/IGORR 2016) (Internet), p.363 - 371, 2016/03

HTTR is graphite moderated and helium gas-cooled reactor with prismatic fuel elements and hexagonal blocks. Here, the graphite block is brittle materials and might be damaged by collision of neighboring blocks by the large earthquake. A seismic observation system is installed in the HTTR site to confirm a behavior of a seismic event. On March 11th, 2011, off the Pacific coast of Tohoku Earthquake of magnitude 9.0 occurred. After the accident at the TEPCO Fukushima Daiichi Nuclear Power Station, the safety of nuclear reactors is the highest importance. To confirm the seismic integrity of HTTR core components, the seismic analysis was carried out using the evaluation waves based on the relationship between the observed earthquake motion at HTTR site and frequency transfer function. In parallel, confirmation tests of primary cooling system on cold state and integrity confirmation of reactor buildings and component support structures were also carried out. As a result, it was found that a stress value of the graphite blocks satisfied an allowable value, and the integrity of the HTTR core components was ensured. The integrity of HTTR core components was also supported by the operation without reactor power in cold conditions of HTTR. The obtained data was compared with the normal plant data before the earthquake. As the result, the integrity of the HTTR facilities was confirmed.

Journal Articles

Elemental analysis system with negative-muon beam

Osawa, Takahito; Ninomiya, Kazuhiko*; Yoshida, Go*; Inagaki, Makoto*; Kubo, Kenya*; Kawamura, Naritoshi*; Miyake, Yasuhiro*

JPS Conference Proceedings (Internet), 8, p.025003_1 - 025003_6, 2015/09

We report a new elemental analysis system that uses an intense negative-muon beam at J-PARC Materials and Life Science Experimental Facility, Muon Science Establishment. This paper presents the preliminary results of measurements for meteorites and standard material. The main system components are a water-cooled electromagnet, an Al flight tube, an Al sample chamber, a lead shielding body, and a Ge detector. Optimum currents for the electromagnet were determined by recording beam profiles with a CCD camera; the muon beam was shaped by collimators. The background and signal-to-noise ratio was significantly better than that obtained in a previous study, and all significant elements in the meteorite and standard samples were detected. Thus, this system can be used for muonic X-ray analysis of extraterrestrial materials.

Journal Articles

Influence of differences between seismic safety evaluation methods for equipment and piping of a nuclear facility

Nishida, Akemi; Iigaki, Kazuhiko; Sawa, Kazuhiro; Li, Y.

Proceedings of 2015 ASME Pressure Vessels and Piping Conference (PVP 2015) (Internet), 7 Pages, 2015/07

The objective of this research was to investigate the influence of differences between methods for evaluating the seismic safety of the equipment and piping of a nuclear facility. For the input ground motion, one wave was chosen from among 200 waves of input ground motions of maximum acceleration of 700-1100 cm/s$$^{2}$$ created for the Oarai District of the Ibaraki Prefecture. Seismic safety evaluations were performed using the conventional method, which relies on floor response spectrum data, and using the multi-input method. The differences between the two methods were summarized. The target equipment and piping system were cooling systems in a model plant. It was found that the response predicted by the multi-input method was approximately half of the response predicted by the conventional method. The third trial evaluation method using the floor response of a three-dimensional building model as input was also reported.

Journal Articles

Seismic response simulation of High-Temperature Engineering Test Reactor building against 2011 Tohoku earthquake

Nishida, Akemi; Nakajima, Norihiro; Kawakami, Yoshiaki; Iigaki, Kazuhiko; Sawa, Kazuhiro

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 7 Pages, 2015/05

The R&D on the three dimensional vibration simulation technologies for a nuclear facility is one of missions of Center for Computational Science and e-Systems, Japan Atomic Energy Agency. Until now, three dimensional building and equipment models of HTTR (High Temperature Engineering Test Reactor) have been constructed and been performed validation of the models by comparison with seismic observed records. In this report, the results obtained by seismic observation simulation on the Tohoku earthquake occurred in the 3/11/2011 using three dimensional models of the HTTR building are shown. The simulation results show good agreement with the real observation data.

Journal Articles

Numerical modeling assistance system in finite element analysis for the structure of an assembly

Nakajima, Norihiro; Nishida, Akemi; Kawakami, Yoshiaki; Suzuki, Yoshio; Sawa, Kazuhiro; Iigaki, Kazuhiko

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 5 Pages, 2015/05

A numerical analysis controlling and managing system is implemented on K, which controls the modelling process and data treating, although the manager only controls a structural analysis by finite element method. The modeling process is described by the list of function ID and its procedures in a data base. The manager executes the process by order in the list for simulation procedures. The manager controls the intention of an analysis by changing the analytical process one to another. Experiments were carried out with static and dynamic analyses.

Journal Articles

Investigation of characteristics of natural circulation of water in vessel cooling system in loss of core cooling test without nuclear heating

Takada, Shoji; Shimizu, Atsushi; Kondo, Makoto; Shimazaki, Yosuke; Shinohara, Masanori; Seki, Tomokazu; Tochio, Daisuke; Iigaki, Kazuhiko; Nakagawa, Shigeaki; Sawa, Kazuhiro

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 5 Pages, 2015/05

In the loss of forced core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of reactor core is stopped without inserting control rods into the core and cooling by Vessel Cooling System (VCS) to demonstrate the inherent safety of HTGR be secured by natural phenomena to make it possible to design a severe accident free reactor. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water cooling tube by thermal reflectors in the VCS, although the safety of reactor is kept. The local higher temperature position was specified although the temperature was sufficiently lower than the maximum allowable working temperature, and natural circulation of water had insufficient cooling effect on the temperature of water cooling tube below 1$$^{circ}$$C. Then, a new safe and secured procedure for the loss of forced core cooling test was established, which will be carried out soon after the restart of HTTR.

154 (Records 1-20 displayed on this page)