Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Kawaguchi, Munemichi; Saito, Junichi; Daido, Hiroyuki*; Suemoto, Toru*
UVSOR-47, P. 85, 2020/08
To elucidate theoretically the transparent metallic sodium in the vacuum ultraviolet (VUV) spectral range, the aim of this research is to obtain the accurate spectrum using UVSOR. We confirmed the validity for the transmittance measurement in UVSOR by the measurement of transmittance of CaF windows. However, the transparency phenomenon of VUV in the metallic sodium has never been confirmed by our group. In the future, we will improve the sodium sample and conduct the measurement again.
Kawaguchi, Munemichi; Saito, Junichi; Daido, Hiroyuki*; Suemoto, Toru*
UVSOR-46, P. 89, 2019/08
To elucidate theoretically the transparent metallic sodium in the vacuum ultraviolet spectral range, the aim of this research is to obtain the accurate spectrum using UVSOR. The sodium sample maintained metallic luster by designing the special cells to prevent from oxidizing. The results of UVSOR measurement showed the possibility to occur the intransparent layer for vacuum ultraviolet light on the MgF windows. In the near future, we will improve the sodium sample to solve the problems and conduct the measurement again
Hasegawa, Noboru; Nishikino, Masaharu; Tomita, Takuro*; Onishi, Naofumi*; Ito, Atsushi*; Eyama, Tsuyoshi*; Kakimoto, Naoya*; Izutsu, Rui*; Minami, Yasuo*; Baba, Motoyoshi*; et al.
X-Ray Lasers and Coherent X-Ray Sources; Development and Applications XI (Proceedings of SPIE, Vol.9589), p.95890A_1 - 95890A_8, 2015/09
Times Cited Count:1 Percentile:54.39(Optics)We have improved a soft X-ray laser (SXRL) interferometer synchronized with a Ti:Sapphire laser pulse to observe the single-shot imaging of the nano-scaled structure dynamics of the laser induced materials. By the precise imaging optics and double time fiducial system having been installed, the lateral resolution on the sample surface and the precision of the temporal synchronization between the SXRL and Ti:Sapphire laser pulses were improved to be 700 nm and 2 ps, respectively. By using this system, the initial stage (before 200 ps) of the ablation process of the Pt surface pumped by 80 fs Ti:Sapphire laser pulse was observed by the comparison between the soft X-ray reflective image and interferogram. We have succeeded in the direct observation of the unique ablation process around the ablation threshold such as the rapid increase of the surface roughness and surface vibration.
Nishikino, Masaharu; Kawachi, Tetsuya; Hasegawa, Noboru; Ishino, Masahiko; Minami, Yasuo*; Suemoto, Toru*; Onishi, Naofumi*; Ito, Atsushi*; Sato, Katsutoshi*; Faenov, A.*; et al.
X-Ray Lasers and Coherent X-Ray Sources; Development and Applications XI (Proceedings of SPIE, Vol.9589), p.958902_1 - 958902_7, 2015/09
Hasegawa, Noboru; Tomita, Takuro*; Nishikino, Masaharu; Eyama, Tsuyoshi*; Kakimoto, Naoya*; Minami, Yasuo*; Baba, Motoyoshi*; Onishi, Naofumi*; Ito, Atsushi*; Kawachi, Tetsuya; et al.
JAEA-Conf 2015-001, p.17 - 20, 2015/07
We have succeeded in simultaneous observation of the ablation front and the expansion front with thin filmy structure in the femto-second laser ablation process of a gold target by using the 13.9 nm soft X-ray probe (incident angle to the sample 70 deg) with soft X-ray interferometer. The dependence on the laser local fluence and materials was obtained by the comparison between gold and tungsten.
Inogamov, N. A.*; Zhakhovsky, V. V.*; Hasegawa, Noboru; Nishikino, Masaharu; Yamagiwa, Mitsuru; Ishino, Masahiko; Agranat, M. B.*; Ashitkov, S. I.*; Faenov, A. Y.*; Khokhlov, V. A.*; et al.
Applied Physics B, 119(3), p.413 - 419, 2015/06
Times Cited Count:6 Percentile:33.34(Optics)Nishikino, Masaharu; Hasegawa, Noboru; Tomita, Takuro*; Eyama, Tsuyoshi*; Kakimoto, Naoya*; Onishi, Naofumi*; Ito, Atsushi*; Baba, Motoyoshi*; Minami, Yasuo*; Kawachi, Tetsuya; et al.
Reza Gakkai Dai-471-Kai Kenkyukai Hokoku; Tanhacho Ryoshi Bimu Hassei To Sono Oyo, p.9 - 12, 2014/12
no abstracts in English
Baba, Motoyoshi*; Nishikino, Masaharu; Hasegawa, Noboru; Tomita, Takuro*; Minami, Yasuo*; Takei, Ryota*; Yamagiwa, Mitsuru; Kawachi, Tetsuya; Suemoto, Toru
Japanese Journal of Applied Physics, 53(8), p.080302_1 - 080302_4, 2014/08
Times Cited Count:8 Percentile:33.58(Physics, Applied)A grazing incidence reflection-type soft X-ay microscope, using a Fresnel zone plate and a soft X-ray laser with wavelength 13.9 nm and pulse width 7 ps, was developed. Submicron size groove structures made on a Pt film were clearly captured at a single shot exposure, with spatial resolution of about 360 nm. A wide field view of 100 m square was secured under the Kohler illumination. This microscope also had a large depth of focus of more than 100 m and was proven to have a sufficient performance for observing surface morphological changes.
Tomita, Takuro*; Nishikino, Masaharu; Hasegawa, Noboru; Minami, Yasuo*; Takei, Ryota*; Baba, Motoyoshi*; Eyama, Tsuyoshi*; Takayoshi, Shodai*; Kaihori, Takeshi*; Morita, Toshimasa; et al.
Journal of Laser Micro/Nanoengineering, 9(2), p.137 - 142, 2014/06
Times Cited Count:5 Percentile:28.65(Nanoscience & Nanotechnology)Femtosecond laser ablation processes on platinum, gold, and tungsten were observed by the single shot pump and probe reflective imaging using a soft X-ray laser probe. To avoid the timing error due to the jitter, we adopted a posteriori correction technique by simultaneous measurement of timing between the pump and probe pulses for every single shot, using a soft X-ray streak camera. A clear difference was found in the temporal behavior of the dynamical response of the soft X-ray reflectivity depending on the irradiated laser fluence in these three materials. On the other hand, the narrow dark rings were found in Pt and W, while an additional bright ring was found outside the dark disk in Au. Our result gives the experimental data comparable with various numerical simulations.
Hasegawa, Noboru; Ochi, Yoshihiro; Kawachi, Tetsuya; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Kaihori, Takeshi; Morita, Toshimasa; Sasaki, Akira; Terakawa, Kota*; et al.
X-Ray Lasers 2012; Springer Proceedings in Physics, Vol.147, p.117 - 120, 2014/00
Times Cited Count:0 Percentile:0.00(Engineering, Electrical & Electronic)We have developed the femto-second laser pump and soft X-ray laser probe system in order to observe the dynamical processes of the femto-second laser ablation. By using this system, we succeed to obtain the temporal evolution of the soft X-ray reflectivity from the laser induced Pt surface. The results lead that the rate of decrease in the reflectivity of the probe beam has a non-linear relation with the pump laser fluence.
Nishikino, Masaharu; Baba, Motoyoshi*; Suemoto, Toru; Hasegawa, Noboru; Ishino, Masahiko; Kaihori, Takeshi; Kawachi, Tetsuya; Yamagiwa, Mitsuru
X-Ray Lasers 2012; Springer Proceedings in Physics, Vol.147, p.199 - 202, 2014/00
Times Cited Count:0 Percentile:0.00(Engineering, Electrical & Electronic)The dynamical processes of the laser-induced surface modifications such as laser ablation come to attract much attention for the micro processing by the ultra-short laser pulse. It is difficult to observe these phenomena directly, because they are non-repetitive, unrepeatable, and occur very rapidly (pico-second) in a very small (micron) area. In order to observe the detailed laser-ablation process, we have developed the proto-type reflected soft X-ray microscopy using the Fresnel zone plate. The experimental setup and spatial resolution of the X-ray microscopy will be presented.
Nishikino, Masaharu; Hasegawa, Noboru; Ishino, Masahiko; Yamagiwa, Mitsuru; Kawachi, Tetsuya; Minami, Yasuo*; Terakawa, Kota*; Takei, Ryota*; Baba, Motoyoshi*; Suemoto, Toru; et al.
JAEA-Conf 2013-001, p.16 - 19, 2013/09
The dynamics of the femtosecond laser ablation is still not clear at the early stage. Several studies on the time-resolved imaging of femtosecond laser ablation process have been performed on various materials. In this study, we have demonstrated a pump and probe imaging of the metal surface morphology during the femtosecond laser ablation by using the laser-driven plasma induced soft X-ray laser (SXRL) as a probe beam. The pumping laser used for ablation was a Ti:Sapphire laser system based on chirped pulse amplification. The pump beam had a Gaussian profile and the focal spot size on the metal surface was about 70 micron at FWHM. The dependence for the pump laser fluence of the ablation surface expansion and the surface condition (roughness and density gradient) were observed from the soft X-ray interferogram and reflective image, respectively.
Nishikino, Masaharu; Hasegawa, Noboru; Tomita, Takuro*; Minami, Yasuo*; Takei, Ryota*; Baba, Motoyoshi*; Eyama, Tsuyoshi*; Takayoshi, Shodai*; Kawachi, Tetsuya; Hatomi, Daiki*; et al.
Proceedings of SPIE, Vol.8849, p.88490E_1 - 88490E_6, 2013/09
Times Cited Count:2 Percentile:72.45(Optics)We have developed the pump and probe interferometer and reflective imaging technique of the metal surfaces during the femtosecond laser ablation by using the laser-driven soft X-ray laser at the wavelength of 13.9 nm. The pumping laser used for ablation was a Ti: Sapphire laser pulse with the duration of 80 fs pulse at a central wavelength of 795 nm, and had a gaussian spatial profile. By using the X-ray imaging technique, the time resolved image of nano-scaled ablation dynamics of the platinum and the gold pumped by a femtosecond laser pulse was obtained.
Tomita, Takuro*; Yamamoto, Minoru*; Hasegawa, Noboru; Terakawa, Kota*; Minami, Yasuo*; Nishikino, Masaharu; Ishino, Masahiko; Kaihori, Takeshi*; Ochi, Yoshihiro; Kawachi, Tetsuya; et al.
Optics Express (Internet), 20(28), p.29329 - 29337, 2012/12
Times Cited Count:20 Percentile:65.84(Optics)Pump and probe reflective imaging using a soft X-ray laser probe was applied to the observation of the early stage of femtosecond laser ablation process on platinum. In strongly excited area, drastic and fast reflectivity drop was observed. In moderately excited area, the decay of the reflectivity is slower than that in the strongly excited area, and the reflectivity reaches its minimum at t = 160 ps. In weakly excited area, laser-induced reflectivity change was not observed. These results give the critical information about the femtosecond laser ablation.
Tomita, Takuro*; Hasegawa, Noboru; Nishikino, Masaharu; Kawachi, Tetsuya; Suemoto, Toru
Reza Kenkyu, 40(8), p.592 - 597, 2012/08
A single-shot soft X-ray laser pulse was used as a probe to investigate the early stage of the laser ablation process on platinum caused by the femtosecond near-infrared pump pulse. From time-resolved interferometry, we observed the dilation of the ablation front on a scale of 10 nm in the picosecond region. In the reflective imaging, we found three distinct types of dynamical responses, depending on the radial position in the pump beam spot. These characteristic behaviors correspond to different laser fluence and were attributed to different ablation schemes: spallation, homogeneous nucleation, and fragmentation/vaporization, which have been predicted from molecular dynamics simulation.
Hasegawa, Noboru; Yamamoto, Minoru*; Terakawa, Kota*; Nishikino, Masaharu; Ochi, Yoshihiro; Minami, Yasuo*; Tomita, Takuro*; Kawachi, Tetsuya; Suemoto, Toru
AIP Conference Proceedings 1465, p.23 - 27, 2012/07
Times Cited Count:0 Percentile:0.00(Physics, Applied)We have developed a soft X-ray laser (SXRL) interferometer capable of the single-shot imaging of nano-scaled structure dynamics. The depth and lateral resolutions of the interferometer were about 1 nm and 1.8 micron, respectively. We observed the initial stage (50 ps) of the ablation process of the Pt surface pumped by a 70 fs Ti:Sapphire laser pulse. The expansion speed of the Pt surface (34 nm/50 ps) indicated that the nano-bubble structures were formed in the initial stage of the ablation. In order to observe the detailed dynamics, the precision of temporal synchronization between the pump and probe pulses was improved to be 3 ps by adopting a portion of the SXRL and pump beams as the time fiducials.
Ochi, Yoshihiro; Terakawa, Kota*; Hasegawa, Noboru; Yamamoto, Minoru*; Tomita, Takuro*; Kawachi, Tetsuya; Minami, Yasuo*; Nishikino, Masaharu; Imazono, Takashi; Ishino, Masahiko; et al.
Japanese Journal of Applied Physics, 51(1), p.016601_1 - 016601_3, 2012/01
Times Cited Count:10 Percentile:39.76(Physics, Applied)We have developed a soft X-ray laser interferometer based on the double Lloyd's mirror and obtained a single shot interferogram by a 7-ps pulse at the wavelength of 13.9 nm. Micrometer grooves with 5-nm depth were successfully reconstructed from the interferogram. The lateral and depth resolutions were estimated to be 1.5 m and better than 1 nm, respectively. This interferometer will be an attractive diagnostic device for observing transiently changing nano-scale deviations on solid surfaces.
Hasegawa, Noboru; Ochi, Yoshihiro; Kawachi, Tetsuya; Terakawa, Kota*; Tomita, Takuro*; Yamamoto, Minoru; Nishikino, Masaharu; Oba, Toshiyuki; Kaihori, Takeshi; Imazono, Takashi; et al.
X-Ray Lasers 2010; Springer Proceedings in Physics, Vol.136, p.353 - 358, 2011/12
The understanding of the dynamics of the initial process is important for the micro processing and welding by the ultra-short laser pulse. The X-ray laser is suitable for probing this initial process because it has short wavelength (Ni-like Ag, 13.9 nm) and short duration (7 ps). For this investigation, the origin of time of the pumping pulse is quite important. In this study, we used the scintillation plate and the plasma gate technique to realize the spatial and temporal synchronization of the pump and probe pulses. For the spatial alignment, a CsI scintillation plate that was set at the sample position was illuminated by both the X-ray laser pulse, and the fluorescence light were detected by the CCD camera. For the temporal synchronization, we set a thin foil at the sample position. We measured the transmission of the X-ray laser while changing a temporal delay of the pumping laser with respect to the time of X-ray laser pulse to obtain the origin of the irradiation time.
Kawachi, Tetsuya; Hasegawa, Noboru; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Oba, Toshiyuki; Kaihori, Takeshi; Kishimoto, Maki; Ochi, Yoshihiro; Tanaka, Momoko; et al.
X-Ray Lasers 2010; Springer Proceedings in Physics, Vol.136, p.15 - 24, 2011/12
This paper reviews recent improvement in the source development of laser-driven X-ray lasers and the applications in the research fields of material science, laser processing, X-ray imaging, and radiation damage in biological cells. In the application for material science, we have firstly observed temporal correlation between the domain structures of ferro-electric substance under the Curie temperature. In the laser processing, new X-ray laser interferometer reveals us the nano-scale surface distortion of substance pumped by a femto-second optical pulse. In the X-ray diffraction image, we have taken several static images of micro-structure of samples: now we are trying to extend the objective to nano-scale dynamics using pump and probe method. In the radiation damage of biological cells, we observed double strand break in DNA using X-ray laser exposure; this results are compared with the case using incoherent several KeV X-ray exposure.
Hasegawa, Noboru; Ochi, Yoshihiro; Kawachi, Tetsuya; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Kaihori, Takeshi; Sasaki, Akira; Terakawa, Kota*; Minami, Yasuo*; et al.
Proceedings of SPIE, Vol.8140, p.81400G_1 - 81400G_8, 2011/10
Times Cited Count:3 Percentile:81.68(Engineering, Electrical & Electronic)We have developed a soft X-ray laser (SXRL) interferometer capable of the single-shot imaging of nano-scaled structure dynamics. The interferometer consisted of the reflection optics including double Lloyd's mirrors and focusing optics, and the interference fringes are produced on the detector surface. By using this interferometer, the initial stage (50 ps) of the ablation process of the Pt surface pumped by a 70 fs Ti:Sapphire laser pulse was observed. The expansion speed of the surface estimated from the result (34 nm/50 ps) indicated that the nano-bubble structures were formed in the initial stage of the ablation. In order to observe the detailed dynamics, the temporal synchronization between the pump and probe pulses was improved to be 3 ps by adopting a portion of the SXRL and pump beams as the time fiducials, to which the pump and probe timing was adjusted by using the X-ray streak camera.