石川 諒尚; 田中 浩基*; 中村 哲志*; 熊田 博明*; 櫻井 良憲*; 渡辺 賢一*; 吉橋 幸子*; 棚上 裕生*; 瓜谷 章*; 鬼柳 善明*
Journal of Radiation Research (Internet), 11 Pages, 2024/10
被引用回数:0From the viewpoints of the advantage depths (ADs), peak tumor dose, and skin dose, we evaluated the effect of neutron beam properties, namely, the ratio between thermal and epithermal neutron fluxes (thermal/epithermal ratio), fast neutron component, and -ray component on the dose distribution. Several parameter surveys were conducted with respect to the beam properties of neutron sources for boron neutron capture therapy assuming boronophenylalanine as the boron agent using our dose calculation tool, called SiDE. The ADs decreased by 3% at a thermal/epithermal ratio of 20% - 30% compared with the current recommendation of . The skin dose increased with the increasing thermal/epithermal ratio, reaching a restricted value of 14 Gy-eq at a thermal/epithermal ratio of . The fast neutron component was modified using two different models, namely, the "linear model," in which the fast neutron intensity decreases log-linearly with the increasing neutron energy, and the "moderator thickness (MT) model," in which the fast neutron component is varied by adjusting the moderator thickness in a virtual beam shaping assembly. Although a higher fast neutron component indicated a higher skin dose, the increment was at a fast neutron component of Gy cm for both models. Furthermore, in the MT model, the epithermal neutron intensity was higher at a fast neutron component of Gy cm compared with the current recommendation of Gy cm. The -ray component also caused no significant disadvantages up to several times larger compared with the current recommendation.
寺阪 祐太; 佐藤 優樹; 瓜谷 章*
Nuclear Instruments and Methods in Physics Research A, 1062, p.169227_1 - 169227_6, 2024/05
被引用回数:0 パーセンタイル:0.00(Instruments & Instrumentation)We have developed a new position-sensitive optical fiber radiation sensor that achieves single-end readout and high dose rate application. The sensor determines the incident position of radiation on the optical fiber by using the wavelength dependency of light attenuation within the fiber. Through the analysis of the output wavelength spectrum from the fiber end, the incident position of radiation on the optical fiber can be inversely estimated using the spectrum unfolding procedure. Using this optical fiber sensor, we conducted a measurement of radiation distribution inside the Fukushima Daiichi Nuclear Power Station (FDNPS). The actual trend of incident position of radiation was successfully reproduced in a high dose rate area, with a maximum dose rate exceeding 100 mSv/h. This validates the effectiveness of our new position-sensitive optical fiber radiation sensor.
寺阪 祐太; 瓜谷 章*
Nuclear Instruments and Methods in Physics Research A, 1049, p.168071_1 - 168071_7, 2023/04
被引用回数:1 パーセンタイル:41.04(Instruments & Instrumentation)A new application of a position-sensitive liquid light guide Cerenkov counter for the simultaneous position detection of Sr/Y and Cs radioactivity in a gamma-ray-dominant environment is proposed. -emitting Sr/Y and -emitting Cs radioactive point sources were measured using a position-sensitive liquid light guide based on the time-of-flight (TOF) method. We found a clear difference in the count rate ratio between the source position peak and reflection peak of the position histogram. Moreover, simultaneous measurements of the radioactive point sources were performed. The results suggest that the source position and activity of Sr/Y and Cs can be simultaneously determined based on the count rate ratio of the source position peak and the reflection peak.
冠城 雅晃; 島添 健次*; 寺阪 祐太; 富田 英生*; 吉橋 幸子*; 山崎 淳*; 瓜谷 章*; 高橋 浩之*
Nuclear Instruments and Methods in Physics Research A, 1046, p.167636_1 - 167636_8, 2023/01
被引用回数:6 パーセンタイル:94.84(Instruments & Instrumentation)波形分別手法を実施せず、強い線場において熱中性子検出器をするための無機シンチレーターの厚さと性質の制御に焦点を当てた。測定では、0.5mmならびに1.0mm厚のGS20(Liガラス)ならびにLiCaAlF結晶(LiCAF:Ce)を採用し、上記のシンチレーターを結合させた光電子増倍管からのパルス信号を1Gspsのデジタル信号処理に入力し、360ns間の波形面積を積分した。Coの線場において、0.5mm厚のGS20では0.919Gy/hまで中性子検出器が可能であった。一方で、0.5mm厚のLiCAF:Ceは、0.473Gy/hまで中性子検出が可能であったが、0.709Gy/hで中性子検出器が不可能であり、中性子/線分別において、GS20は、より良いエネルギー分解能と高中性子検出効率により、LiCAF:Ceよりも優れている結果であった。
寺阪 祐太; 渡辺 賢一*; 瓜谷 章*
放射線(インターネット), 47(3), p.89 - 96, 2022/10
We developed a novel single-end readout type position-sensitive optical fiber radiation sensor. This sensor measures the radiation intensity distribution along the fiber with light readout only from single end of the optical fiber. To estimate the radiation intensity distribution, we analyzed the wavelength spectrum output at single end of the fiber, which contains information about the transmission distance of light inside the fiber. Based on the unfolding of the wavelength spectrum, the radiation intensity distribution along the fiber could be estimated. The effects of wavelength channel selection and signal-to-noise ratio of the wavelength spectrum on radiation distribution estimation were evaluated. In addition, we performed that our optical fiber sensor could estimate the radiation intensity distribution under the dose rate of 3 Gy/h. The dose rate detection limit was estimated to be 21 mGy/h for the irradiation range of 20 cm.
平田 悠歩; 佐藤 達彦; 渡辺 賢一*; 小川 達彦; Parisi, A.*; 瓜谷 章*
Journal of Nuclear Science and Technology, 59(7), p.915 - 924, 2022/07
被引用回数:11 パーセンタイル:90.95(Nuclear Science & Technology)放射線測定において、検出器の線量応答を高い信頼性を持って評価することは、放射線治療,放射線防護,高エネルギー物理学など、多様な分野で共通した課題となる。しかし、多くの蛍光現象を利用する放射線検出器では、高い線エネルギー付与(LET)を持つ放射線に対して消光効果と呼ばれる検出効率の低下を示すことが知られている。また、この消光現象は、異なる種類の粒子線による微小領域へのエネルギー付与分布の変化にも依存する。先行研究では、PHITSコードのマイクロドジメトリ計算により消光現象を予測する手法が開発されていた。本研究では、この成果を活用して、PHITSのマイクロドジメトリ計算により、BaFBr:Eu検出器の光刺激蛍光(OSL)効率を予測した。また、He, C, Neのイオンビーム照射実験を行い、BaFBr:Eu検出器の発光効率変化を測定し、計算による予測値を検証した。本検証では、PHITSのマイクロドジメトリ計算でターゲット球の直径を30-50nmと設定することで、発光効率の予測値が実験値を再現した。また、計算によりBaFBr:Euの発光効率の粒子線種に対する依存性を明らかにし、PHITSのマイクロドジメトリ計算がBaFBr:EuのOSL測定結果を正確に予測できることを示した。
寺阪 祐太; 渡辺 賢一*; 瓜谷 章*
Nuclear Instruments and Methods in Physics Research A, 1034, p.166793_1 - 166793_6, 2022/07
被引用回数:4 パーセンタイル:63.92(Instruments & Instrumentation)In this study, a single-end readout type position-sensitive optical fiber radiation sensor was developed. Using the wavelength dependency of light attenuation inside the optical fiber, the incident position of radiation at the fiber can be estimated reversely. Instead of a spectrometer, we employed bandpass filters and photon-counting head as a photodetector to improve detection efficiency. The detection efficiency of a 10 m long plastic scintillation fiber at the 5 m position from the readout end was evaluated to be in the range of 0.08-0.12 % for 662 keV gamma-rays from Cs and 2.6-3.9 % for beta-rays from Sr/Y when a bandpass filter transmitting photons with a wavelength of 500 nm was used. A basic measurement test of radiation intensity distribution was conducted using a Sr/Y radioactive point source. A field test was also performed at the difficult-to-return zone in Fukushima Prefecture, and the estimated dose rate distribution roughly agreed with the survey meter measurement.
笹田 星児*; Takahashi, Yoshihito*; Takeuchi, Keisuke*; 廣井 孝介; Su, Y. H.; 篠原 武尚; 渡辺 賢一*; 瓜谷 章*
Japanese Journal of Applied Physics, 61(4), p.046004_1 - 046004_8, 2022/03
被引用回数:0 パーセンタイル:0.00(Physics, Applied)Residual strains in a punched electrical steel sheet increase the iron loss in the steel sheet. To accurately estimate the effect of residual strain on iron loss, the residual strain distribution in a punched electrical steel sheet should be evaluated. In this study, we demonstrated the two- dimensional imaging of the residual strain distribution in a punched electrical steel sheet using the neutron Bragg-edge transmission imaging method. To improve the accuracy of strain measurement with minimal deterioration of spatial resolution, we applied a process of superposing many specimen images. The tensile strain near the punched edge and the compressive strain inside the core were experimentally confirmed using this method. Finally, the neutron Bragg-edge imaging results and those obtained from kernel average misorientation map using electron backscattered diffraction were compared to verify the validity of the proposed method.
笹田 星児*; 廣井 孝介; 小山内 健太*; 篠原 武尚; Watanabe, K.*; 瓜谷 章*
Japanese Journal of Applied Physics, 60(12), p.126003_1 - 126003_6, 2021/12
被引用回数:4 パーセンタイル:29.17(Physics, Applied)The evaluation of the magnetization distribution inside a bulk magnet is important for ensuring the performance of automotive motors because it strongly depends on the quality of magnetization inside the permanent magnet. In the conventional destructive method, it is difficult to accurately measure the magnetization with a high spatial resolution. The polarized neutron imaging technique can be used to visualize the distribution of the magnetic flux density inside a magnet nondestructively. In this study, we demonstrated the imaging of the magnetization distribution using polarized neutrons in an anisotropic ferrite magnet sample. The 2D distribution of the magnetization was experimentally obtained by polarized neutron imaging with a high spatial resolution of less than 1 mm. Furthermore, the validity of the results was confirmed by comparing them with those obtained using the conventional destructive method.
寺阪 祐太; 渡辺 賢一*; 瓜谷 章*; 山崎 淳*; 佐藤 優樹; 鳥居 建男; 若井田 育夫
Journal of Nuclear Engineering and Radiation Science, 7(4), p.042002_1 - 042002_7, 2021/10
福島第一原子力発電所原子炉建物内の高線量率環境での線源分布測定への応用を目指し、波長スペクトルのアンフォールディング処理に基づく光ファイバーを用いた新しい一次元放射線分布測定法を開発した。開発した手法は光ファイバー内を伝搬する光の減衰量が波長依存であることを利用して、光ファイバー端から出力された波長スペクトルをアンフォールディングすることにより、光ファイバーへの放射線の入射位置を逆推定するというものである。この手法は光強度の積分値を利用するため、パルスカウンティングを行う放射線検出器を使用した場合に高線量率環境下で発生する計数損失や信号パイルアップの問題を回避することができる。本研究では紫外光源とSr/Y放射線源を用いた基礎実験を行い、線源位置検出の基本特性を確認した。
寺阪 祐太; 渡辺 賢一*; 瓜谷 章*
Nuclear Instruments and Methods in Physics Research A, 996, p.165151_1 - 165151_8, 2021/04
被引用回数:3 パーセンタイル:40.24(Instruments & Instrumentation)福島第一原子力発電所建屋内における放射線分布測定を目的として、小口径石英光ファイバーの一次元位置敏感型センサーとしての基礎評価を行った。本センサーは光ファイバーと放射線の相互作用により発生するチェレンコフ光の飛行時間情報から放射線の入射位置を決定する。プラスチックシンチレーション光ファイバーを用いた従来のセンサーと比較して、石英光ファイバーは位置分解能がより優れることが分かった。これは、チェレンコフ光の発光寿命が短いことによりタイミング特性が向上したためと考えられた。加えて、本センサーの高放射線環境下での動作特性について、20mSv/hまでの出力線形性及び積算1kGyまでの耐放射線特性を評価した。
寺阪 祐太; 渡辺 賢一*; 瓜谷 章*; 山崎 淳*; 佐藤 優樹; 鳥居 建男; 若井田 育夫
Proceedings of International Youth Nuclear Congress 2020 (IYNC 2020) (Internet), 4 Pages, 2020/05
For the application in the measurement of the high dose rate hot spots inside the Fukushima Daiichi Nuclear Power Station buildings, we propose a wavelength-resolved type one-dimensional radiation distribution sensing method using plastic scintillating fiber (PSF). The proposing method estimates the incident position of radiation to the PSF by the unfolding of the wavelength spectrum output from the fiber edge using the fact that the attenuation length of scintillating light depends on the wavelength. By measuring the response function in advance, which defined as the wavelength spectrum measured at the fiber edge by the spectrometer with every transmission distance, the spectrum which can obtain when measured a certain radiation distribution can be expressed as the convolution of the response function. This method can avoid the problem of chance coincidence effect and signal pile-up, which occurs in the radiation detector with pulse counting mode under high dose rate field because this method measures the integrated light intensity. Through basic experiment using the ultraviolet irradiation source and Sr point source, basic properties of inverse estimation of irradiated position were confirmed, which showed that source position was reasonably estimated using the response function which obtained by the ultraviolet irradiation source in advance.
及川 健一; 鬼柳 善明*; 佐藤 博隆*; 大前 良磨*; Pham, A.*; 渡辺 賢一*; 松本 吉弘*; 篠原 武尚; 甲斐 哲也; Harjo, S.; et al.
Materials Research Proceedings, Vol.15, p.207 - 213, 2020/02
Japanese swords are very attractive not only as a work of art but also a metallurgical point of view. Since Japanese vintage swords became valuable, it is indispensable to establish non-destructive analysis method to identify some peculiar characteristics. Bragg edge imaging gives real-space distributions of bulk information in a crystalline material as well as neutron tomography. In this work, we investigated crystallographic information of a Japanese sword made by Sukemasa in Izumi province in the first quarter of the 16th century. The experiments have been performed at RADEN at J-PARC. The Sukemasa sword was measured with a counting-type 2D detector and with a CCD camera. We are now analyzing the measured 2D-transmission spectra using RITS code to obtain spatial distribution of the crystallite size, the texture variation, the d110 shift and its broadening. Complementary data analysis using white beam tomography is also on going. Detailed analysis results will be presented.
静間 俊行; 宇都宮 弘章*; Mohr, P.*; 早川 岳人; 後神 進史*; 牧永 あや乃*; 秋宗 秀俊*; 山県 民穂*; 太田 雅久*; 大垣 英明*; et al.
Physical Review C, 72(2), p.025808_1 - 025808_9, 2005/08
被引用回数:46 パーセンタイル:90.67(Physics, Nuclear)産業技術総合研究所のレーザー逆コンプトン線を用いて、W, Re, Os核の光核反応実験を行い、中性子放出のしきい値エネルギー近傍の詳細な断面積を測定した。得られた実験データと核統計模型による計算値との比較を行い、良い一致が得られた。Os核には、励起エネルギー9.75keVに第一励起状態が存在しており、元素合成過程の高温状態下では、この状態が強く生成されていたと考えられる。そこで、今回得た光核反応Os()の断面積データを用いて、Os第一励起状態からの中性子捕獲反応断面積の評価を行い、Re-Os宇宙時計に適用した。
谷村 嘉彦; 吉澤 道夫; 三枝 純; 藤井 克年; 清水 滋; 吉田 真; 柴田 泰成*; 瓜谷 章*; 工藤 勝久*
Radiation Protection Dosimetry, 110(1-4), p.85 - 89, 2004/09
被引用回数:19 パーセンタイル:74.89(Environmental Sciences)日本原子力研究所放射線標準施設棟では4MVペレトロン型加速器を利用した単色中性子校正場を開発している。中性子スペクトルの評価を行い、中性子フルエンスに関するトレーサビリティを確立することにより144keV,565keV,5.0MeVの中性子校正場が構築された。
井口 哲夫*; 渡辺 賢一*; 河原林 順*; 瓜谷 章*; 榎田 洋一*; 渡部 和男
JAERI-Tech 2004-010, 62 Pages, 2004/03
短パルス・高繰り返し率で適切な出力強度の得られる波長可変レーザーを用いて、中性子ドジメトリーへ共鳴アブレーション(RLA)現象を効果的に活用するため、理論モデルにより最適条件、すなわち、高感度性と元素選択性の両立を図ることのできる条件を探索した。その結果、従来の低繰り返しレーザーと比べ、約100倍検出感度を改善できることを実証した。さらに、改良型RLA-質量分析システムにより、14MeVDT中性子照射を行った高純度Al試料中に生成された極微量長半減期核種Al-26を明瞭に検出することに成功し、本分析手法に基づく中性子ドジメトリー手法の実現可能性を示すことができた。
辻村 憲雄; 吉田 忠義; 河原林 順*; 水野 良治*; 中 亮太郎*; 瓜谷 章*; 渡辺 賢一*
JNC TY8400 2003-010, 46 Pages, 2003/03
通常光ファイバーを利用した広域の放射線分布を連続的に測定することができる放射線検出システムを開発した。光減衰の小さい通常光ファイバーを使用することにより、従来使用されてきたプラスチックシンチレーションファイバーに比べ、測定可能範囲が約100mへと約2桁伸ばすことができた。
源河 次雄; 岩本 清吉; 竹内 紀男; 瓜谷 章*; 森 千鶴夫*
Nuclear Instruments and Methods in Physics Research A, 339, p.398 - 401, 1994/00
被引用回数:6 パーセンタイル:56.89(Instruments & Instrumentation)金属イリジウム-192線源を微少熱量計を用いて非破壊で放射能を測定した。線源からの放射線を全て吸収して熱エネルギーに変換するために、タングステン製の放射線吸収体を作製して用いた。試料となる線源は、0.110mmのIr-Pt合金を0.1mm厚のPtで被覆したものである。約60MBqの線源を3.2%の不確かさ以内で測定することができた。熱量計による測定値は、電離箱による値より約10%高いが、熱量測定では、放射線の線源内での自己吸収による影響がないので、その差が出たものである。
吉田 真; 山本 敏生*; Wu, Y.*; 新谷 徹*; 瓜谷 章*; 森 千鶴夫*
Nuclear Instruments and Methods in Physics Research A, 330, p.158 - 164, 1993/00
被引用回数:9 パーセンタイル:66.73(Instruments & Instrumentation)放射性ガスの放射能を長軸比例計数管内拡散法により直接測定を行なう研究をした。この方法は、比例計数管に放射性ガスを封入して放射能絶対測定をする上で問題となる端効果を除く方法としてきわめて有効である。この測定の際必要な基礎データをArの計数管内挙動をモニタリングすることにより収集し評価した。その結果、十分な精度で放射能の決定が行なえることがわかった。また、端効果とともに重要な補正である壁効果についても実験及び計算により評価した。
寺阪 祐太; 佐藤 優樹; 渡辺 賢一*; 瓜谷 章*; 鳥居 建男
no journal, ,
福島第一原子力発電所(以下、1F)事故による1Fサイト内汚染の効率的な除染及び作業員の外部被ばく線量の低減のためには、放射性物質が周辺と比較して多く集積している場所(ホットスポット)の詳細な分布測定が必要である。放射性物質分布を計測する手段として、1F事故後よりプラスチックシンチレーションファイバー(PSF)にTime-of-Flight(TOF)法を適用した放射線分布測定法(以下、TOF光ファイバー法)が1F汚染水タンク周りからの汚染水漏洩監視等の現場で応用されている。本手法を汚染が深刻な1F原子炉建屋内に適用するためには高線量率対応が必要となるが、TOF光ファイバー法は高線量率照射時に偶発同時計数が問題となる。そこで、本研究ではTOF法の偶発同時計数特性を実験的に確認し、その補正法の検討を行った。