Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Nagai, Yuya; Shuji, Yoshiyuki; Kawasaki, Takeshi; Aita, Takahiro; Kimura, Yasuhisa; Nemoto, Yasunori*; Onuma, Takeshi*; Tomiyama, Noboru*; Hirano, Koji*; Usui, Yasuhiro*; et al.
JAEA-Technology 2022-039, 117 Pages, 2023/06
Japan Atomic Energy Agency (JAEA) manages wide range of nuclear facilities. Many of these facilities are required to be performed adjustment with the aging and complement with the new regulatory standards and the earthquake resistant, since the Great East Japan Earthquake and the Fukushima Daiichi Nuclear Power Station accident. It is therefore desirable to promote decommissioning of facilities that have reached the end of their productive life in order to reduce risk and maintenance costs. However, the progress of facility decommissioning require large amount of money and radioactive waste storage space. In order to address these issues, JAEA has formulated a "The Medium/Long-Term Management Plan of JAEA Facilities" with three pillars: (1) consolidation and prioritization of facilities, (2) assurance of facility safety, and (3) back-end countermeasures. In this plan, Plutonium Fuel Fabrication Facility has been selected as primary decommissioned facility, and dismantling of equipment in the facilities have been underway. In this report, size reduction activities of the glove box W-9 and a part of tunnel F-1, which was connected to W-9, are presented, and the obtained findings are highlighted. The glovebox W-9 had oxidation & reduction furnace, and pellet crushing machine as equipment interior. The duration of activity took six years from February 2014 to February 2020, including suspended period of 4 years due to the enhanced authorization approval process.
Kitamura, Akane; Yamaki, Tetsuya*; Yuri, Yosuke*; Koshikawa, Hiroshi*; Sawada, Shinichi*; Yuyama, Takahiro*; Usui, Aya; Chiba, Atsuya*
Nuclear Instruments and Methods in Physics Research B, 460, p.254 - 258, 2019/12
Times Cited Count:2 Percentile:21.15(Instruments & Instrumentation)Poly(vinylidene-fluoride) (PVDF) film is suitable for investigation of the size of etchable ion tracks because we can clearly judge the finish of the track etching and the surrounding bulk area remains due to the high chemical stability. Thereby we can measure the radius of ion tracks of each ion. In this study, we focused on two irradiation conditions for controlling the size of etchable ion tracks of PVDF films. One was irradiation in an oxygen atmosphere and the other was a fullerene (C) cluster beam irradiation. SEM observation showed that the size of pores became larger by irradiation in an oxygen atmosphere. It was found that the oxidation of ion tracks widened the size of etchable ion tracks. The C
irradiation caused larger etchable tracks on the PVDF surface. The result could represent the effect of local and simultaneous collisions by the swift aggregated ions.
Usui, Aya; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; Hashizume, Masashi*; et al.
Dai-28-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.117 - 119, 2015/12
no abstracts in English
Usui, Takahiro*; Sawada, Akihiko; Amaya, Masaki; Suzuki, Akihiro*; Chikada, Takumi*; Terai, Takayuki*
Journal of Nuclear Science and Technology, 52(10), p.1318 - 1322, 2015/10
Times Cited Count:51 Percentile:96.88(Nuclear Science & Technology)SiC coating is one of countermeasures for the prevention of oxidation and hydrogen embrittlement of fuel claddings because SiC has high resistance of oxidation and hydrogen permeation. Hydrogen permeation and oxidation experiments for the cladding materials with SiC coatings were conducted in unirradiated conditions. The sputtering method was employed to make SiC coatings. In the hydrogen permeation experiment, SUS316 was used as a base material of the coating. SUS316 with SiC coatings showed hydrogen permeation reduction by one order of magnitude. In the oxidation experiments, Zry-4 and SUS316 were used as base materials of the coatings. The weight gain of the Zry-4 specimens with a SiC coating decreased by about one-fifth compared to the uncoated ones. This phenomenon was observed for SUS316 at 750 C as well. The peel-off of the coating was observed in some experiments, and it is considered that the peel-off was caused by the difference of the thermal expansions between coatings and base materials. Thicker coatings showed better oxidation resistance, but thinner coatings showed more tolerance of peel-off.
Yuyama, Takahiro; Ishibori, Ikuo; Kurashima, Satoshi; Yoshida, Kenichi; Ishizaka, Tomohisa; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Miyawaki, Nobumasa; et al.
Proceedings of 12th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.302 - 304, 2015/09
no abstracts in English
Usui, Aya; Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; et al.
Dai-27-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.118 - 121, 2015/03
no abstracts in English
Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Okubo, Takeru; Nara, Takayuki; et al.
JAEA-Review 2013-059, JAEA Takasaki Annual Report 2012, P. 179, 2014/03
Three electrostatic accelerators at TIARA were operated on schedule in fiscal year 2012 except changing its schedule by cancellations of users. The yearly operation time of the 3 MV tandem accelerator, the 400 kV ion implanter and the 3MV single-ended accelerator were in the same levels as the ordinary one, whose operation time totaled to 2,073, 1,847 and 2,389 hours, respectively. The tandem accelerator had no trouble, whereas the ion implanter and the single-ended accelerator stopped by any troubles for one day and four days, respectively. The molecular ion beam of helium hydride was generated by the ion implanter, because the users required irradiation of several cluster ions in order to study the effect of irradiation. As a result, its intensity of beam was 50 nA at 200 kV. The ion beam of tungsten (W) at 15 MeV was accelerated by the tandem accelerator, whose intensity was 20 nA at charge state of 4+, because of the request from a researcher in the field of nuclear fusion.
Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Matoba, Shiro; Chiba, Atsuya; Yokoyama, Akihito; Usui, Aya; Sato, Takahiro; Okubo, Takeru; Uno, Sadanori
JAEA-Review 2013-059, JAEA Takasaki Annual Report 2012, P. 159, 2014/03
no abstracts in English
Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; et al.
Dai-26-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.79 - 81, 2013/07
Three electrostatic accelerators at TIARA were operated on schedule in fiscal year 2012 except changing its schedule by cancellations of users. The yearly operation time of the 3MV tandem accelerator, the 400 kV ion implanter and the 3 MV single-ended accelerator were in the same levels as the ordinary one, whose operation time totaled to 2,073, 1,847 and 2,389 hours, respectively. The tandem accelerator had no trouble, whereas the ion implanter and the single-ended accelerator stopped by any troubles for one day and four days, respectively. The ion implanter generated molecular ion beam of helium hydride by using the Freeman type ion source, because of the request from the user. As a result, its intensity of beam was 50 nA at 200 kV.
Uchida, Shunsuke*; Sato, Tomonori; Morishima, Yusuke*; Hirose, Tatsuya*; Miyazawa, Takahiro*; Kakinuma, Nagao*; Sato, Yoshiyuki*; Usui, Naoshi*; Wada, Yoichi*
Proceedings of 12th International Conference on Environmental Degradation of Materials in Nuclear Power Systems-Water Reactors (CD-ROM), p.19 - 29, 2005/00
Static and dynamic responses of stainless steel specimens exposed to HO
and O
in high temperature water were evaluated by analyzing ECP and FDCI (frequency dependent complex impedance). The oxide films on the specimens were characterized by multilateral surface analyses, e.g., LRS, SIMS, XPS and direct electric resistance measurement. As a result of evaluation, it was confirmed that (1) corrosive condition of BWR normal water chemistry (NWC) was simulated by 100 ppb H
O
without co-existing O
, while that of hydrogen water chemistry (HWC) was simulated by 10 ppb H
O
, (2) ECP under HWC was as high as that under NWC, while dissolution rate of oxide film under HWC was much lower than that under NWC, (3) combination effects of electric resistance and dissolution rate of oxide caused same level ECP for both NWC and HWC, and (4) distinct weight loss of the specimen exposed to 100 ppb H
O
was observed.
Usui, Takahiro; Komiyama, Daisuke; Amaya, Masaki; Suzuki, Akihiro*; Terai, Takayuki*
no journal, ,
Oxidation experiments of the SiC coating on the Zry-4 plates were conducted. It was observed that the SiC coating on the Zry-4 specimens has oxidation resistance at 1200C for 30 min. The peel-off of the coating were observed at 1000
C and more. It is possible that the peel-off of the coating was affected by the reaction between SiC coating and Zry-4 substrates.
Usui, Takahiro*; Sawada, Akihiko; Amaya, Masaki; Suzuki, Akihiro*; Chikada, Takumi*; Terai, Takayuki*
no journal, ,
SiC coatings were fabricated on SUS316 and Zircaloy-4 substrate. Hydrogen permeation experiment and oxidation experiment were performed. From hydrogen permeation experiment to SiC coated specimen on SUS316 subsrate, permeability of specimen was smaller in one order in magnitude than that of uncoated. From oxidation experiment on Zircaloy-4 substrate, weight gain and thickness of oxide film decreased. Specimens with thicker coating has less weight gain than that with thinner coating, however, thicker coating was peeled off more than thinner coating after oxidized in 1200C.
Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Matoba, Shiro; Chiba, Atsuya; Yokoyama, Akihito; Usui, Aya; Sato, Takahiro; Okubo, Takeru; Uno, Sadanori
no journal, ,
no abstracts in English
Usui, Takahiro; Sawada, Akihiko; Amaya, Masaki; Suzuki, Akihiro*; Terai, Takayuki*
no journal, ,
Coating on cladding material is one of the candidate as "Accident Toralent Fuel". In this study, SiC coating was fabricated on SUS316 substrate and performed oxdation experiment under LOCA condition. Oxidation of iron decreased in the specimen with coating. The specimen coated for 1 hour showed the best integrity of oxidation.
Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Matoba, Shiro; Chiba, Atsuya; Yokoyama, Akihito; Usui, Aya; Sato, Takahiro; Okubo, Takeru; Uno, Sadanori
no journal, ,
no abstracts in English