Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 152

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Low electron temperature in ablating materials formed by picosecond soft X-ray laser pulses

Ishino, Masahiko; Hasegawa, Noboru; Nishikino, Masaharu; Pikuz, T.*; Skobelev, I. Y.*; Faenov, A.*; Inogamov, N.*; Kawachi, Tetsuya; Yamagiwa, Mitsuru

X-Ray Lasers and Coherent X-Ray Sources; Development and Applications XI (Proceedings of SPIE, Vol.9589), p.958904_1 - 958904_6, 2015/09

 Times Cited Count:1 Percentile:55.61

To study the ablation process induced by the soft X-ray laser pulse, we investigated the electron temperature of the ablating material. Focused soft X-ray laser pulses having a wavelength of 13.9 nm and duration of 7 ps were irradiated onto target surfaces, and we observed the optical emission from surfaces by use of an optical camera. On target surfaces, we could confirm damage structures, but no emission signal in the visible spectral range during ablation could be observed. Then, we estimated the electron temperature in the ablating matter, and we estimated the electron temperature to be lower than 1 eV and the process duration was shorter than 1000 ps. This result is in good accordance with the theoretical prediction. Our investigation implies that the spallative ablation occurs in the low electron temperature region of a non-equilibrium state of warm dense matter. We will present the current state of our eperimental results.

Journal Articles

Observation of dynamics and modification of solid surface using a picosecond soft X-ray laser

Nishikino, Masaharu; Kawachi, Tetsuya; Hasegawa, Noboru; Ishino, Masahiko; Minami, Yasuo*; Suemoto, Toru*; Onishi, Naofumi*; Ito, Atsushi*; Sato, Katsutoshi*; Faenov, A.*; et al.

X-Ray Lasers and Coherent X-Ray Sources; Development and Applications XI (Proceedings of SPIE, Vol.9589), p.958902_1 - 958902_7, 2015/09

Journal Articles

The Observation of a transient surface morphology in the femtosecond laser ablation process by using the soft X-ray laser probe

Hasegawa, Noboru; Nishikino, Masaharu; Tomita, Takuro*; Onishi, Naofumi*; Ito, Atsushi*; Eyama, Tsuyoshi*; Kakimoto, Naoya*; Izutsu, Rui*; Minami, Yasuo*; Baba, Motoyoshi*; et al.

X-Ray Lasers and Coherent X-Ray Sources; Development and Applications XI (Proceedings of SPIE, Vol.9589), p.95890A_1 - 95890A_8, 2015/09

 Times Cited Count:1 Percentile:55.61

We have improved a soft X-ray laser (SXRL) interferometer synchronized with a Ti:Sapphire laser pulse to observe the single-shot imaging of the nano-scaled structure dynamics of the laser induced materials. By the precise imaging optics and double time fiducial system having been installed, the lateral resolution on the sample surface and the precision of the temporal synchronization between the SXRL and Ti:Sapphire laser pulses were improved to be 700 nm and 2 ps, respectively. By using this system, the initial stage (before 200 ps) of the ablation process of the Pt surface pumped by 80 fs Ti:Sapphire laser pulse was observed by the comparison between the soft X-ray reflective image and interferogram. We have succeeded in the direct observation of the unique ablation process around the ablation threshold such as the rapid increase of the surface roughness and surface vibration.

Journal Articles

Soft X-ray laser observation of femtosecond-laser-driven ablation of tungsten

Nishikino, Masaharu; Hasegawa, Noboru; Ishino, Masahiko; Ochi, Yoshihiro; Kawachi, Tetsuya; Yamagiwa, Mitsuru; Kato, Yoshiaki*

Chinese Optics Letters, 13(7), p.070002_1 - 070002_3, 2015/07

 Times Cited Count:1 Percentile:7.02(Optics)

Journal Articles

Observation of the dependence on the fluence and materials in femto-second laser ablation process by using the soft X-ray laser probe

Hasegawa, Noboru; Tomita, Takuro*; Nishikino, Masaharu; Eyama, Tsuyoshi*; Kakimoto, Naoya*; Minami, Yasuo*; Baba, Motoyoshi*; Onishi, Naofumi*; Ito, Atsushi*; Kawachi, Tetsuya; et al.

JAEA-Conf 2015-001, p.17 - 20, 2015/07

We have succeeded in simultaneous observation of the ablation front and the expansion front with thin filmy structure in the femto-second laser ablation process of a gold target by using the 13.9 nm soft X-ray probe (incident angle to the sample $$sim$$ 70 deg) with soft X-ray interferometer. The dependence on the laser local fluence and materials was obtained by the comparison between gold and tungsten.

Journal Articles

Hydrodynamics driven by ultrashort laser pulse; Simulations and the optical pump - X-ray probe experiment

Inogamov, N. A.*; Zhakhovsky, V. V.*; Hasegawa, Noboru; Nishikino, Masaharu; Yamagiwa, Mitsuru; Ishino, Masahiko; Agranat, M. B.*; Ashitkov, S. I.*; Faenov, A. Y.*; Khokhlov, V. A.*; et al.

Applied Physics B, 119(3), p.413 - 419, 2015/06

 Times Cited Count:6 Percentile:34.58(Optics)

Journal Articles

Observation of femtosecond laser ablation on Tungsten by using soft X-ray reflection and interference imaging

Nishikino, Masaharu; Hasegawa, Noboru; Tomita, Takuro*; Eyama, Tsuyoshi*; Kakimoto, Naoya*; Onishi, Naofumi*; Ito, Atsushi*; Baba, Motoyoshi*; Minami, Yasuo*; Kawachi, Tetsuya; et al.

Reza Gakkai Dai-471-Kai Kenkyukai Hokoku; Tanhacho Ryoshi Bimu Hassei To Sono Oyo, p.9 - 12, 2014/12

no abstracts in English

Journal Articles

Very low electron temperature in warm dense matter formed by focused picosecond soft X-ray laser pulses

Ishino, Masahiko; Hasegawa, Noboru; Nishikino, Masaharu; Pikuz, T. A.*; Skobelev, I. Y.*; Faenov, A.*; Inogamov, N. A.*; Kawachi, Tetsuya; Yamagiwa, Mitsuru

Journal of Applied Physics, 116(18), p.183302_1 - 183302_6, 2014/11

 Times Cited Count:9 Percentile:38.3(Physics, Applied)

We investigated the optical emission from the ablating surfaces induced by the irradiations of soft X-ray laser (SXRL) pulses with the aim of estimation of the maximum electron temperature. No emission signal in the spectral range of 400-800 nm could be observed despite the formation of damage structures on the target surfaces. Hence, we estimated an upper limit for the electron temperature of 0.4-0.7 eV for the process duration of 100-1000 ps. Our results imply that the ablation and/or surface modification by the SXRL is not accompanied by plasma formation but is induced by thermo-mechanical pressure, which is so called a spallative ablation. This spallative ablation process occurs in the low electron temperature region of a non-equilibrium state of warm dense matter.

Journal Articles

Submicron scale image observation with a grazing incidence reflection-type single-shot soft X-ray microscope

Baba, Motoyoshi*; Nishikino, Masaharu; Hasegawa, Noboru; Tomita, Takuro*; Minami, Yasuo*; Takei, Ryota*; Yamagiwa, Mitsuru; Kawachi, Tetsuya; Suemoto, Toru

Japanese Journal of Applied Physics, 53(8), p.080302_1 - 080302_4, 2014/08

 Times Cited Count:7 Percentile:31.01(Physics, Applied)

A grazing incidence reflection-type soft X-ay microscope, using a Fresnel zone plate and a soft X-ray laser with wavelength 13.9 nm and pulse width 7 ps, was developed. Submicron size groove structures made on a Pt film were clearly captured at a single shot exposure, with spatial resolution of about 360 nm. A wide field view of 100 $$mu$$m square was secured under the Kohler illumination. This microscope also had a large depth of focus of more than 100 $$mu$$m and was proven to have a sufficient performance for observing surface morphological changes.

Journal Articles

Time-resolved soft X-ray imaging of femtosecond laser ablation process in metals

Tomita, Takuro*; Nishikino, Masaharu; Hasegawa, Noboru; Minami, Yasuo*; Takei, Ryota*; Baba, Motoyoshi*; Eyama, Tsuyoshi*; Takayoshi, Shodai*; Kaihori, Takeshi*; Morita, Toshimasa; et al.

Journal of Laser Micro/Nanoengineering, 9(2), p.137 - 142, 2014/06

 Times Cited Count:5 Percentile:29.68(Nanoscience & Nanotechnology)

Femtosecond laser ablation processes on platinum, gold, and tungsten were observed by the single shot pump and probe reflective imaging using a soft X-ray laser probe. To avoid the timing error due to the jitter, we adopted a posteriori correction technique by simultaneous measurement of timing between the pump and probe pulses for every single shot, using a soft X-ray streak camera. A clear difference was found in the temporal behavior of the dynamical response of the soft X-ray reflectivity depending on the irradiated laser fluence in these three materials. On the other hand, the narrow dark rings were found in Pt and W, while an additional bright ring was found outside the dark disk in Au. Our result gives the experimental data comparable with various numerical simulations.

Journal Articles

Current status and future prospects of "J-KAREN"; High contrast, high intensity laser for studying relativistic laser-matter interactions

Kiriyama, Hiromitsu; Mori, Michiaki; Okada, Hajime; Shimomura, Takuya; Nakai, Yoshiki*; Tanoue, Manabu; Kondo, Shuji; Kanazawa, Shuhei; Yogo, Akifumi; Sagisaka, Akito; et al.

JPS Conference Proceedings (Internet), 1, p.015095_1 - 015095_5, 2014/03

We present the design and characterization of a high-contrast, petawatt-class Ti:sapphire chirped-pulse amplification (CPA) laser system. Two saturable absorbers and low-gain optical parametric chirped-pulse amplification (OPCPA) preamplifier in the double CPA laser chain have improved the temporal contrast to 1.4$$times$$10$$^{12}$$ on the subnanosecond time scale at 70 terawatt level. Final uncompressed broadband pulse energy is 28 J, indicating the potential for reaching peak power near 600 terawatt. We also discuss our upgrade to over petawatt level at a 0.1 Hz repetition rate briefly.

Journal Articles

Development of soft X-ray microscopy using Fresnel zone plate for observation of laser-induce surface dynamics

Nishikino, Masaharu; Baba, Motoyoshi*; Suemoto, Toru; Hasegawa, Noboru; Ishino, Masahiko; Kaihori, Takeshi; Kawachi, Tetsuya; Yamagiwa, Mitsuru

X-Ray Lasers 2012; Springer Proceedings in Physics, Vol.147, p.199 - 202, 2014/00

 Times Cited Count:0 Percentile:0

The dynamical processes of the laser-induced surface modifications such as laser ablation come to attract much attention for the micro processing by the ultra-short laser pulse. It is difficult to observe these phenomena directly, because they are non-repetitive, unrepeatable, and occur very rapidly (pico-second) in a very small (micron) area. In order to observe the detailed laser-ablation process, we have developed the proto-type reflected soft X-ray microscopy using the Fresnel zone plate. The experimental setup and spatial resolution of the X-ray microscopy will be presented.

Journal Articles

Observation of the laser-induced surface dynamics using the single-shot soft X-ray laser probe

Hasegawa, Noboru; Ochi, Yoshihiro; Kawachi, Tetsuya; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Kaihori, Takeshi; Morita, Toshimasa; Sasaki, Akira; Terakawa, Kota*; et al.

X-Ray Lasers 2012; Springer Proceedings in Physics, Vol.147, p.117 - 120, 2014/00

 Times Cited Count:0 Percentile:0

We have developed the femto-second laser pump and soft X-ray laser probe system in order to observe the dynamical processes of the femto-second laser ablation. By using this system, we succeed to obtain the temporal evolution of the soft X-ray reflectivity from the laser induced Pt surface. The results lead that the rate of decrease in the reflectivity of the probe beam has a non-linear relation with the pump laser fluence.

Journal Articles

Measurement of femtosecond laser ablation by soft X-ray laser interferometory and reflective imaging

Nishikino, Masaharu; Hasegawa, Noboru; Ishino, Masahiko; Yamagiwa, Mitsuru; Kawachi, Tetsuya; Minami, Yasuo*; Terakawa, Kota*; Takei, Ryota*; Baba, Motoyoshi*; Suemoto, Toru; et al.

JAEA-Conf 2013-001, p.16 - 19, 2013/09

The dynamics of the femtosecond laser ablation is still not clear at the early stage. Several studies on the time-resolved imaging of femtosecond laser ablation process have been performed on various materials. In this study, we have demonstrated a pump and probe imaging of the metal surface morphology during the femtosecond laser ablation by using the laser-driven plasma induced soft X-ray laser (SXRL) as a probe beam. The pumping laser used for ablation was a Ti:Sapphire laser system based on chirped pulse amplification. The pump beam had a Gaussian profile and the focal spot size on the metal surface was about 70 micron at FWHM. The dependence for the pump laser fluence of the ablation surface expansion and the surface condition (roughness and density gradient) were observed from the soft X-ray interferogram and reflective image, respectively.

Journal Articles

Nano-meter scale modifications on material surfaces induced by soft X-ray laser pulse irradiations

Ishino, Masahiko; Faenov, A.*; Tanaka, Momoko; Tamotsu, Satoshi*; Pikuz, T.; Hasegawa, Noboru; Nishikino, Masaharu; Inogamov, N.*; Skobelev, I.*; Fortov, V.*; et al.

Proceedings of SPIE, Vol.8849, p.88490F_1 - 88490F_8, 2013/09

 Times Cited Count:2 Percentile:73.17

Journal Articles

Observation of the nano-scale surface dynamics of femtosecond laser ablation by time-resolved soft X-ray imaging technique

Nishikino, Masaharu; Hasegawa, Noboru; Tomita, Takuro*; Minami, Yasuo*; Takei, Ryota*; Baba, Motoyoshi*; Eyama, Tsuyoshi*; Takayoshi, Shodai*; Kawachi, Tetsuya; Hatomi, Daiki*; et al.

Proceedings of SPIE, Vol.8849, p.88490E_1 - 88490E_6, 2013/09

 Times Cited Count:2 Percentile:73.17

We have developed the pump and probe interferometer and reflective imaging technique of the metal surfaces during the femtosecond laser ablation by using the laser-driven soft X-ray laser at the wavelength of 13.9 nm. The pumping laser used for ablation was a Ti: Sapphire laser pulse with the duration of 80 fs pulse at a central wavelength of 795 nm, and had a gaussian spatial profile. By using the X-ray imaging technique, the time resolved image of nano-scaled ablation dynamics of the platinum and the gold pumped by a femtosecond laser pulse was obtained.

Journal Articles

Ultra-intense, high spatio-temporal quality petawatt-class laser system and applications

Kiriyama, Hiromitsu; Shimomura, Takuya; Mori, Michiaki; Nakai, Yoshiki*; Tanoue, Manabu; Kondo, Shuji; Kanazawa, Shuhei; Pirozhkov, A. S.; Esirkepov, T. Z.; Hayashi, Yukio; et al.

Applied Sciences (Internet), 3(1), p.214 - 250, 2013/03

 Times Cited Count:15 Percentile:50(Chemistry, Multidisciplinary)

This paper reviews techniques for improving the temporal contrast and spatial beam quality in an ultra-intense laser system that is based on chirped-pulse amplification (CPA). We describe the design, performance, and characterization of our laser system, which has the potential for achieving a peak power of 600 TW. We also describe applications of the laser system in the relativistically dominant regime of laser-matter interactions and discuss a compact, high efficiency diode-pumped laser system.

Journal Articles

Experimental verification of femtosecond laser ablation schemes by time-resolved soft X-ray reflective imaging

Tomita, Takuro*; Yamamoto, Minoru*; Hasegawa, Noboru; Terakawa, Kota*; Minami, Yasuo*; Nishikino, Masaharu; Ishino, Masahiko; Kaihori, Takeshi*; Ochi, Yoshihiro; Kawachi, Tetsuya; et al.

Optics Express (Internet), 20(28), p.29329 - 29337, 2012/12

 Times Cited Count:18 Percentile:65.08(Optics)

Pump and probe reflective imaging using a soft X-ray laser probe was applied to the observation of the early stage of femtosecond laser ablation process on platinum. In strongly excited area, drastic and fast reflectivity drop was observed. In moderately excited area, the decay of the reflectivity is slower than that in the strongly excited area, and the reflectivity reaches its minimum at t = 160 ps. In weakly excited area, laser-induced reflectivity change was not observed. These results give the critical information about the femtosecond laser ablation.

Journal Articles

Temporal contrast enhancement of petawatt-class laser pulses

Kiriyama, Hiromitsu; Shimomura, Takuya; Sasao, Hajime; Nakai, Yoshiki*; Tanoue, Manabu; Kondo, Shuji; Kanazawa, Shuhei; Pirozhkov, A. S.; Mori, Michiaki; Fukuda, Yuji; et al.

Optics Letters, 37(16), p.3363 - 3365, 2012/08

 Times Cited Count:38 Percentile:85.95(Optics)

We demonstrate the temporal contrast enhancement in a petawatt-class Ti:sapphire chirped-pulse amplification (CPA) laser system. An extra saturable absorber, introduced downstream a low gain optical parametric chirped-pulse amplification (OPCPA) preamplifier, has improved the temporal contrast in the system to 1.4$$times$$10$$^{12}$$ on the sub-nanosecond time scale at 70 TW power level. We have achieved 28 J of uncompressed broadband output energy with this system, indicating the potential for reaching peak powers near 600 TW.

Journal Articles

Observation of the laser-induced surface dynamics by the single-shot X-ray laser interferometer

Hasegawa, Noboru; Ochi, Yoshihiro; Kawachi, Tetsuya; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Kaihori, Takeshi; Sasaki, Akira; Terakawa, Kota*; Minami, Yasuo*; et al.

Proceedings of SPIE, Vol.8140, p.81400G_1 - 81400G_8, 2011/10

 Times Cited Count:3 Percentile:82.27

We have developed a soft X-ray laser (SXRL) interferometer capable of the single-shot imaging of nano-scaled structure dynamics. The interferometer consisted of the reflection optics including double Lloyd's mirrors and focusing optics, and the interference fringes are produced on the detector surface. By using this interferometer, the initial stage ($$sim$$50 ps) of the ablation process of the Pt surface pumped by a 70 fs Ti:Sapphire laser pulse was observed. The expansion speed of the surface estimated from the result (34 nm/50 ps) indicated that the nano-bubble structures were formed in the initial stage of the ablation. In order to observe the detailed dynamics, the temporal synchronization between the pump and probe pulses was improved to be 3 ps by adopting a portion of the SXRL and pump beams as the time fiducials, to which the pump and probe timing was adjusted by using the X-ray streak camera.

152 (Records 1-20 displayed on this page)