Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Sheng, Q.*; Kaneko, Tatsuya*; Yamakawa, Kohtaro*; Guguchia, Z.*; Gong, Z.*; Zhao, G.*; Dai, G.*; Jin, C.*; Guo, S.*; Fu, L.*; et al.
Physical Review Research (Internet), 4(3), p.033172_1 - 033172_14, 2022/09
Iwamoto, Yosuke; Taniguchi, Shingo*; Nakao, Noriaki*; Itoga, Toshio*; Nakamura, Takashi*; Nakane, Yoshihiro; Nakashima, Hiroshi; Satoh, Daiki; Yashima, Hiroshi*; Yamakawa, Hiroshi*; et al.
Proceedings of 8th Specialists' Meeting on Shielding Aspects of Accelerators, Targets and Irradiation Facilities (SATIF-8), p.195 - 203, 2010/03
Neutron energy spectra at 0 degree produced from stopping-length thick graphite, aluminum, iron and lead targets bombarded by 250 MeV and 350 MeV protons were measured at the neutron TOF course at RCNP of Osaka University. The neutron energy spectra were obtained by using the time-of-flight technique in the energy range from 10 MeV to incident proton energy. To compare the experimental results, Monte Carlo calculations by the PHITS and MCNPX codes using the JENDL-HE and the LA150 evaluated nuclear data files were performed. It was found that these calculated results at 0-degree generally underestimated the experimental results for all targets in the energy range above 20 MeV.
Iwamoto, Yosuke; Taniguchi, Shingo*; Nakao, Noriaki*; Itoga, Toshio*; Nakamura, Takashi*; Nakane, Yoshihiro; Nakashima, Hiroshi; Satoh, Daiki; Yashima, Hiroshi*; Yamakawa, Hiroshi*; et al.
JAEA-Conf 2006-009, p.118 - 123, 2006/11
Neutron energy spectra produced at the forward direction from thick graphite, aluminum, iron and lead targets bombarded by 250 MeV protons were measured by the TOF method at RCNP of Osaka University. The experimental data were compared with the calculated results of the PHITS, MCNPX codes. All calculations give lower neutron energy spectra than the experimental ones for all targets above 20 MeV and must be improved for neutron production at 0-degree. These experimental data will be useful as benchmark data for investigating the accuracy of the Monte Carlo simulation and for the shielding design of accelerator facilities.
Iwamoto, Yosuke; Taniguchi, Shingo*; Nakao, Noriaki*; Itoga, Toshio*; Nakamura, Takashi*; Nakane, Yoshihiro; Nakashima, Hiroshi; Satoh, Daiki; Yashima, Hiroshi*; Yamakawa, Hiroshi*; et al.
Nuclear Instruments and Methods in Physics Research A, 562(2), p.789 - 792, 2006/06
Times Cited Count:6 Percentile:44.5(Instruments & Instrumentation)Neutron energy spectra produced from thick targets play an important role in validation of calculation codes that are employed in the design of spallation neutron sources and the shielding design of accelerator facilities. However, appropriate experimental data were scarce in the forward direction for the incident energy higher than 100 MeV. In this study, neutron spectra at 0 degree from thick targets bombarded with 350 MeV protons were measured by the time-of-flight technique using an NE213. The targets used were graphite, Al, Fe and Pb and their thicknesses were chosen to be a little thicker than the stopping lengths. The experiment was carried out at the TOF course of the RCNP (Research Center of Nuclear Physics) ring cyclotron, Osaka University. The flight path length between center of the target and of an NE213 were 11.4 m for the measurement of low energy neutrons and 95 m for high energy neutrons. The experimental data are compared with the calculated results by using the Monte Carlo transport codes, such as MCNPX and PHITS codes.
Yamakawa, Koji*; Chimi, Yasuhiro; Ishikawa, Norito; Iwase, Akihiro*
Journal of Alloys and Compounds, 370(1-2), p.211 - 216, 2004/05
Times Cited Count:1 Percentile:12.54(Chemistry, Physical)The migration of hydrogen in Pd-1at.% Fe-H and Pd-1at.% Ag-H alloys is investigated by electrical resistivity measurement around 50 K. The disordered hydrogen atoms are introduced by electron irradiation with 0.5 MeV electrons below 15 K. The disordered atoms order by migration of hydrogen atoms during the heating-up of the specimens. The recovery curves of electrical resistivity have two sub-stages for electron irradiated specimens and one stage for fast cooled specimens. The migration energy of hydrogen is obtained from the kinetic analysis of the resistivity change due to the ordering, using the cross-cut method for the electron irradiated specimen and fast cooled specimen. The obtained value of the migration energy for the low temperature stage is smaller than that for the high temperature stage. The value for the high temperature stage is similar to the energy for the case of fast cooling. The difference between the hydrogen atoms disordered by irradiation and that by fast cooling is discussed for Pd based alloys.
Chimi, Yasuhiro; Adachi, Koichi*; Iwase, Akihiro; Ishikawa, Norito; Yamakawa, Koji*
Journal of Alloys and Compounds, 330-332(1-2), p.187 - 190, 2002/01
Times Cited Count:3 Percentile:29.84(Chemistry, Physical)no abstracts in English
Daido, Hiroyuki; Yamakawa, Koichi; Yamagiwa, Mitsuru; Arisawa, Takashi; Kato, Yoshiaki; Noda, Akira*; Uesaka, Mitsuru*; Ogata, Atsushi*; Matsukado, Koji*
Proceedings of 4th Symposium on Accelerator and Related Technology for Application, p.111 - 112, 2001/10
no abstracts in English
Iwamoto, Yosuke; Taniguchi, Shingo*; Nakao, Noriaki*; Itoga, Toshio*; Nakamura, Takashi*; Nakane, Yoshihiro; Nakashima, Hiroshi; Satoh, Daiki; Yashima, Hiroshi*; Yamakawa, Hiroshi*; et al.
no journal, ,
Neutron energy spectra at 0 degree produced from stopping-length thick graphite, aluminum, iron and lead targets bombarded by 250 MeV and 350 MeV protons were measured at the neutron TOF course at RCNP of Osaka University. The neutron energy spectra were obtained by using the time-of-flight technique in the energy range from 10 MeV to incident proton energy. To compare the experimental data, Monte Carlo calculations by PHITS and MCNPX codes using the JENDL-HE and the LA150 evaluated files were performed. It was found that these calculation results at 0-degree generally underestimated the experimental data for all targets in the energy range above 20 MeV.