Refine your search:     
Report No.
 - 
Search Results: Records 1-9 displayed on this page of 9
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

The $$^{59}$$Fe(n,$$gamma$$)$$^{60}$$Fe cross section from the surrogate ratio method and its effect on the $$^{60}$$Fe nucleosynthesis

Yan, S. Q.*; Li, X. Y.*; Nishio, Katsuhisa; Lugaro, M.*; Li, Z. H.*; Makii, Hiroyuki; Pignatari, M.*; Wang, Y. B.*; Orlandi, R.; Hirose, Kentaro; et al.

Astrophysical Journal, 919(2), p.84_1 - 84_7, 2021/10

 Times Cited Count:1 Percentile:8.87(Astronomy & Astrophysics)

Journal Articles

Arc discharge characteristics of a long pulse ion source for the KSTAR neutral beam injector

Chang, D. H.*; Jeong, S. H.*; Jin, J. T.*; Chang, D. S.*; Kim, T. S.*; Lee, K. W.*; In, S. R.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Journal of the Korean Physical Society, 59(2), p.275 - 280, 2011/08

 Times Cited Count:3 Percentile:27.54(Physics, Multidisciplinary)

A long pulse ion source (LPIS) for the neutral beam injector (NBI) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) superconducting tokamak. The arc discharge characteristics of the ion source were investigated on the first KSTAR neutral beam injector (NBI-1). The ion source consists of a magnetic bucket plasma generator with multi-pole cusp fields and a set of prototype tetrode accelerators with circular apertures. Stable and efficient arc plasmas up to an arc power of 70 kW have been produced by using a constant power-mode operation of the arc power supply. The reliable operation region of the arc discharges has been investigated for various filament heating voltages, arc powers, and amounts of injected deuterium gas.

Journal Articles

Results of beam extraction performance for the KSTAR neutral beam injector

Chang, D. H.*; Jeong, S. H.*; Kim, T. S.*; Lee, K. W.*; In, S. R.*; Jin, J. T.*; Chang, D. S.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Japanese Journal of Applied Physics, 50(6), p.066302_1 - 066302_7, 2011/06

 Times Cited Count:11 Percentile:43.98(Physics, Applied)

A stable ion beam extraction of the LPIS-1 was achieved up to 85 kV/32 A for a 5 s pulse length and 80 kV/25 A for a 14 s pulse length. An optimum beam perveance of 1.15 $$mu$$perv was observed at an acceleration voltage of 60 kV. Neutralization efficiency was measured by a water-flow calorimetry (WFC) method using a calorimeter and the operation of a bending magnet. The full-energy species of ion beams were detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6-1.1 A/kW depending on the operating conditions of arc discharge. A neutral beam power of 1.0 MW must be sufficiently injected into the KSTAR plasmas from the LPIS-1 at a beam energy of 80 keV.

Journal Articles

Identified charged hadron production in $$p + p$$ collisions at $$sqrt{s}$$ = 200 and 62.4 GeV

Adare, A.*; Afanasiev, S.*; Aidala, C.*; Ajitanand, N. N.*; Akiba, Yasuyuki*; Al-Bataineh, H.*; Alexander, J.*; Aoki, Kazuya*; Aphecetche, L.*; Armendariz, R.*; et al.

Physical Review C, 83(6), p.064903_1 - 064903_29, 2011/06

 Times Cited Count:184 Percentile:99.44(Physics, Nuclear)

Transverse momentum distributions and yields for $$pi^{pm}, K^{pm}, p$$, and $$bar{p}$$ in $$p + p$$ collisions at $$sqrt{s}$$ = 200 and 62.4 GeV at midrapidity are measured by the PHENIX experiment at the RHIC. We present the inverse slope parameter, mean transverse momentum, and yield per unit rapidity at each energy, and compare them to other measurements at different $$sqrt{s}$$ collisions. We also present the scaling properties such as $$m_T$$ and $$x_T$$ scaling and discuss the mechanism of the particle production in $$p + p$$ collisions. The measured spectra are compared to next-to-leading order perturbative QCD calculations.

Journal Articles

Azimuthal correlations of electrons from heavy-flavor decay with hadrons in $$p+p$$ and Au+Au collisions at $$sqrt{s_{NN}}$$ = 200 GeV

Adare, A.*; Afanasiev, S.*; Aidala, C.*; Ajitanand, N. N.*; Akiba, Yasuyuki*; Al-Bataineh, H.*; Alexander, J.*; Aoki, Kazuya*; Aphecetche, L.*; Aramaki, Y.*; et al.

Physical Review C, 83(4), p.044912_1 - 044912_16, 2011/04

 Times Cited Count:9 Percentile:49.7(Physics, Nuclear)

Measurements of electrons from the decay of open-heavy-flavor mesons have shown that the yields are suppressed in Au+Au collisions compared to expectations from binary-scaled $$p+p$$ collisions. Here we extend these studies to two particle correlations where one particle is an electron from the decay of a heavy flavor meson and the other is a charged hadron from either the decay of the heavy meson or from jet fragmentation. These measurements provide more detailed information about the interaction between heavy quarks and the quark-gluon matter. We find the away-side-jet shape and yield to be modified in Au+Au collisions compared to $$p+p$$ collisions.

Journal Articles

Measurement of neutral mesons in $$p$$ + $$p$$ collisions at $$sqrt{s}$$ = 200 GeV and scaling properties of hadron production

Adare, A.*; Afanasiev, S.*; Aidala, C.*; Ajitanand, N. N.*; Akiba, Y.*; Al-Bataineh, H.*; Alexander, J.*; Aoki, K.*; Aphecetche, L.*; Armendariz, R.*; et al.

Physical Review D, 83(5), p.052004_1 - 052004_26, 2011/03

 Times Cited Count:177 Percentile:98.48(Astronomy & Astrophysics)

The PHENIX experiment at RHIC has measured the invariant differential cross section for production of $$K^0_s$$, $$omega$$, $$eta'$$ and $$phi$$ mesons in $$p + p$$ collisions at $$sqrt{s}$$ = 200 GeV. The spectral shapes of all hadron transverse momentum distributions are well described by a Tsallis distribution functional form with only two parameters, $$n$$ and $$T$$, determining the high $$p_T$$ and characterizing the low $$p_T$$ regions for the spectra, respectively. The integrated invariant cross sections calculated from the fitted distributions are found to be consistent with existing measurements and with statistical model predictions.

Journal Articles

Commissioning results of the KSTAR neutral beam system

Bae, Y. S.*; Park, Y. M.*; Kim, J. S.*; Han, W. S.*; Kwak, S. W.*; Chang, Y. B.*; Park, H. T.*; Song, N. H.*; Chang, D. H.*; Jeong, S. H.*; et al.

Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 9 Pages, 2011/03

The neutral beam injection (NBI) system is designed to provide the ion heating and current drive for the high performance operation and long pulse operation of the Korean Superconducting Tokamak Advanced Research (KSTAR). The KSTAR NBI consists of two beam lines. Each beam line contains three ion sources of which one ion source has been designed to deliver more than 2.5 MW of deuterium neutral beam power with maximum 120-keV beam energy. Consequently, the final goal of the KSTAR NBI system aims to inject more than 14 MW of deuterium beam power with the two beam lines. According to the planned NBI system, the first NBI system is to demonstrate the beam injection from one ion source into the KSTAR tokamak plasma in 2010 campaign including the system commissioning of each components and subsystems. In this paper, the construction and the commissioning of the first NBI system with one ion source is presented.

Journal Articles

Status and result of the KSTAR upgrade for the 2010's campaign

Yang, H. L.*; Kim, Y. S.*; Park, Y. M.*; Bae, Y. S.*; Kim, H. K.*; Kim, K. M.*; Lee, K. S.*; Kim, H. T.*; Bang, E. N.*; Joung, M.*; et al.

Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 8 Pages, 2011/03

Because the 2010 operation of Korea Superconducting Tokamak Advanced Research (KSTAR) mainly aims to achieve strongly elongated and diverted plasma, all the necessary hardware systems to provide an essential circumstance for the plasma shaping were newly installed and upgraded in 2010. In this paper, general configuration of the upgraded systems described earlier will be outlined. Moreover, several key performances and test results of the systems will be also reported in summary.

JAEA Reports

Development of Phased Mission Analysis Program with Monte Carlo Method - Improvement of the variance reduction technique with biasing towards top event -

Yang Jin An*;

JNC TN9400 99-013, 89 Pages, 1998/12

JNC-TN9400-99-013.pdf:2.0MB

This report presents a variance reduction technique to estimate the reliability and availability of highly complex systems during phased mission time using the Monte Carlo simulation. In this study, we introduced the variance reduction technique with a concept of distance between the present system state and the cut set configurations. Using this technique, it becomes possible to bias the tansition from the operating states to the failed states of components towards the closest cut set. Therefore a component failure can drive the system towards a cut set configuration more effectively. JNC developed the PHAMMON (Phased Mission Analysis Program with Monte Carlo Method) code which involved the two kinds of variance reduction techniques : (1) forced transition, and (2)failure biasing. However, these techniques did not guarantee an effective reduction in variance. For further improvement, a variance reduction technique incorporating the distance concept was introduced to the PHAMMON code and the numerical calculation was carried out for the different design cases of decay heat removal system in a large fast breeder reactor. Our results indicate that the technique addition of this incorporating distance concept is an effective means of further reducing the variance.

9 (Records 1-9 displayed on this page)
  • 1