Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 34

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Utilization of gamma ray irradiation at the WASTEF Facility

Sano, Naruto; Yamashita, Naoki; Watanabe, Masaya; Tsukada, Manabu*; Hoshino, Kazutoyo*; Hirai, Koki; Ikegami, Yuta*; Tashiro, Shinsuke; Yoshida, Ryoichiro; Hatakeyama, Yuichi; et al.

JAEA-Technology 2023-029, 36 Pages, 2024/03

JAEA-Technology-2023-029.pdf:2.47MB

At the Waste Safety Testing Facility (WASTEF), the gamma ray irradiation device "Gamma Cell 220" was relocated from the 4th research building of the Nuclear Science Research Institute in FY2019, and the use of gamma ray irradiation has begun. Initially, Fuel Cycle Safety Research Group, Fuel Cycle Safety Research Division, Nuclear Safety Research Center, Sector of Nuclear Safety Research and Emergency Preparedness, the owner of this device, conducted the tests as the main user, but since 2022, other users, including those outside the organization, have started using it. The gamma ray irradiation device "Gamma Cell 220" is manufactured by Nordion International Inc. in Canada. Since it was purchased in 1989, the built-in 60Co radiation source has been updated once, and safety research related to nuclear fuel cycles, etc. It is still used for this purpose to this day. This report summarizes the equipment overview of the gamma ray irradiation device "Gamma Cell 220", its permits and licenses at WASTEF, usage status, maintenance and inspection, and future prospects.

Journal Articles

Reviewing codes and standards for long term operation in Japan

Murakami, Kenta*; Arai, Taku*; Yamada, Koji*; Momma, Kensuke*; Tsuji, Takashi*; Nakagawa, Nobuyuki*; Onizawa, Kunio

Transactions of the 27th International Conference on Structural Mechanics in Reactor Technology (SMiRT 27) (Internet), 3 Pages, 2024/03

This paper studied the future vision of codes and standards in Japan by systematically comparing Japanese regulatory rules, standards, and industry guides related to long term operation with international safety standards, and confirmed that the Japanese standard system generally meets their recommendations. The recommendation for the future improvements of Japanese codes and standards were summarized into five items.

Journal Articles

Comparison of cosmic-ray environments on earth, moon, mars and in spacecraft using PHITS

Sato, Tatsuhiko; Nagamatsu, Aiko*; Ueno, Haruka*; Kataoka, Ryuho*; Miyake, Shoko*; Takeda, Kazuo*; Niita, Koji*

Radiation Protection Dosimetry, 180(1-4), p.146 - 149, 2018/08

 Times Cited Count:14 Percentile:81.29(Environmental Sciences)

Cosmic-ray dose rates spatially and temporally change very much. In this study, we compared the calculated cosmic-ray environments on the Earth, Moon, and Mars as well as inside spacecraft on low-earth orbit (LEO) and at interplanetary space. In the calculation, a galactic cosmic-ray model developed in DLR and trapped proton/electron models AP9/AE9 were used for determining the incident cosmic-ray fluxes, and the Particle and Heavy Ion Transport code System, PHITS, was employed for the cosmic-ray transport simulation in the Earth, Lunar, and Martian systems as well as spacecraft. The virtual International Space Station (ISS) model developed by JAXA was adopted as the representative of spacecraft in the PHITS simulation. This paper focuses on the comprehensive discussions on the difference of cosmic-ray environments and the effective methods of their shielding in various exposure situations.

Journal Articles

Radiation damage calculation in PHITS and benchmarking experiment for cryogenic-sample high-energy proton irradiation

Iwamoto, Yosuke; Matsuda, Hiroki; Meigo, Shinichiro; Satoh, Daiki; Nakamoto, Tatsushi*; Yoshida, Makoto*; Ishi, Yoshihiro*; Kuriyama, Yasutoshi*; Uesugi, Tomonori*; Yashima, Hiroshi*; et al.

Proceedings of 61st ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams (HB 2018) (Internet), p.116 - 121, 2018/07

The radiation damage model in the radiation transport code PHITS has been developed to calculate the basic data of the radiation damage including the energy of the target Primary Knock on Atom (PKA). For the high-energy proton incident reactions, a target PKA created by the secondary particles was more dominant than a target PKA created by the projectile. To validate the radiation damage model in metals irradiated by $$>$$100 MeV protons, we developed a proton irradiation device with a Gifford-McMahon cryocooler to cryogenically cool wire samples. By using this device, the defect-induced electrical resistivity changes related to the DPA cross section of copper and aluminum were measured under irradiation with 125 and 200 MeV protons at cryogenic temperature. A comparison of the experimental data with the calculated results indicates that the DPA cross section with defect production efficiencies provide better quantitative descriptions.

JAEA Reports

Study on engineering technologies in the Mizunami Underground Research Laboratory (FY 2014); Development of recovery and mitigation technology on excavation damage (Contract research)

Fukaya, Masaaki*; Hata, Koji*; Akiyoshi, Kenji*; Sato, Shin*; Takeda, Nobufumi*; Miura, Norihiko*; Uyama, Masao*; Kaneda, Tsutomu*; Ueda, Tadashi*; Hara, Akira*; et al.

JAEA-Technology 2016-002, 195 Pages, 2016/03

JAEA-Technology-2016-002.pdf:46.3MB
JAEA-Technology-2016-002-appendix(CD-ROM).zip:16.11MB

The researches on examination of the plug applied to the future reflood test was conducted as a part of (5) development of technologies for restoration and/on reduction of the excavation damage relating to the engineering technology in the MIU (2014), specifically focused on (1) plug examination (e.g. functions, structure and material) and the quality control methods and (2) analytical evaluation of rock mass behavior around the plug through the reflood test. As the result, specifications of the plug were determined. These specifications should be able to meet requirements for the safety structure and surrounding rock mass against predicted maximum water pressure, temperature stress and seismic force, and for controlling the groundwater inflow, ensuring the access into the reflood gallery and the penetration performance of measurement cable. Also preliminary knowledge regarding the rock mass behavior around the plug after flooding the reflood gallery by installed plug was obtained.

Journal Articles

Development of laser beam injection system for the Edge Thomson Scattering (ETS) in ITER

Yatsuka, Eiichi; Hatae, Takaki; Suito, Satoshi*; Ohara, Miyuki*; Hagita, Koji*; Inoue, Kazunori*; Bassan, M.*; Walsh, M.*; Itami, Kiyoshi

Journal of Instrumentation (Internet), 11(1), p.C01006_1 - C01006_12, 2016/01

 Times Cited Count:7 Percentile:30.82(Instruments & Instrumentation)

Journal Articles

Improvement of fission gas analyzer

Uehara, Hiroyuki; Komuro, Kazuma; Usami, Koji; Nihei, Yasuo; Nakata, Masahito

Proceedings of 52nd Annual Meeting of Hot Laboratories and Remote Handling Working Group (HOTLAB 2015) (Internet), 5 Pages, 2015/09

For the accurate measurement of the released FP gas during RIA, Gas Chromatograph was improved with the hardware approach and the software one. As the hardware approach, PDD was added to the gas detector of GC and it can detect 50 times higher sensitivity compared with the TCD. As the software approach, ETG function was adopted to deconvolute the overlapped Kr peak from N$$_{2}$$ one. With ETG estimation, Kr volume can be evaluated with the deconvolution from N$$_{2}$$ peak in neither the long measurement time nor the changing measurement condition.

JAEA Reports

Study on engineering technologies in the Mizunami Underground Research Laboratory (FY 2013); Development of recovery and mitigation technology on excavation damage (Contract research)

Fukaya, Masaaki*; Hata, Koji*; Akiyoshi, Kenji*; Sato, Shin*; Takeda, Yoshinori*; Miura, Norihiko*; Uyama, Masao*; Kaneda, Tsutomu*; Ueda, Tadashi*; Toda, Akiko*; et al.

JAEA-Technology 2014-040, 199 Pages, 2015/03

JAEA-Technology-2014-040.pdf:37.2MB

The researches on engineering technology in the Mizunami Underground Research Laboratory (MIU) project consists of (1) development of design and construction planning technologies, (2) development of construction technology, (3) development of countermeasure technology, (4) development of technology for security, and (5) development of technologies for restoration and/or reduction of the excavation damage. The researches on engineering technology such as verification of the initial design were being conducted by using data measured during construction as a part of the second phase of the MIU plan. Examination about the plug for reflood test in the GL-500m Access/Research Gallery-North as part of the development of technologies for restoration and/or reduction of excavation damage were carried out. Specifically, Literature survey was carried out about the plug, based on the result of literature survey, examination of the design condition, design of the plug and rock stability using numerical simulation, selection of materials for major parts, and grouting for water inflow from between rock and plug, were carried out in this study.

JAEA Reports

Study on engineering technologies in the Mizunami Underground Research Laboratory; FY2012 (Contract research)

Fukaya, Masaaki*; Noda, Masaru*; Hata, Koji*; Takeda, Yoshinori*; Akiyoshi, Kenji*; Ishizeki, Yoshikazu*; Kaneda, Tsutomu*; Sato, Shin*; Shibata, Chihoko*; Ueda, Tadashi*; et al.

JAEA-Technology 2014-019, 495 Pages, 2014/08

JAEA-Technology-2014-019.pdf:82.23MB

The researches on engineering technology in the Mizunami Underground Research Laboratory (MIU) plan consists of (1) research on engineering technology deep underground, and (2) research on engineering technology as a basis of geological disposal. The former research is mainly aimed in this study, which is categorized in (a) development of design and construction planning technologies, (b) development of construction technologies, (c) development of countermeasure technologies, and (d) development of technologies for security. In this study, the researches on engineering technology are being conducted in these four categories by using data measured during construction as a part of the second phase of the MIU plan.

Journal Articles

Evaluation of dose level in a laser-driven ion accelerator using PHITS code

Sakaki, Hironao; Fukuda, Yuji; Nishiuchi, Mamiko; Jinno, Satoshi; Kanasaki, Masato; Yogo, Akifumi; Kondo, Kiminori; Saito, Fumihiro; Fukami, Tomoyo; Ueno, Masayuki; et al.

Progress in Nuclear Science and Technology (Internet), 4, p.182 - 185, 2014/04

The concept of a compact ion particle accelerator has become attractive in view of recent progress in laser-driven ions acceleration. In the development of many applications of laser-accelerated ions, it is necessary for securing the radiation safety to calculate the dose evaluation. The dose was measured with the radio-photoluminescent (RPL) glass dosimeter on the test beamline of at laser-driven accelerator. The Monte Carlo code, PHITS (Particle and Heavy Ion Transport code system) simulation is shown to be reasonably predictive at the test beamline for measured with the RPL glass dosimeter. We compare of the measured dose level on the laser-driven accelerator with the result of PHITS code in this report.

Journal Articles

Measurements of electron-induced neutrons as a tool for determination of electron temperature of fast electrons in the task of optimization laser-produced plasma ions acceleration

Sakaki, Hironao; Nishiuchi, Mamiko; Maeda, Shota; Sagisaka, Akito; Pirozhkov, A. S.; Pikuz, T.; Faenov, A.*; Ogura, Koichi; Fukami, Tomoyo; Matsukawa, Kenya*; et al.

Review of Scientific Instruments, 85(2), p.02A705_1 - 02A705_4, 2014/02

 Times Cited Count:2 Percentile:11.15(Instruments & Instrumentation)

High intensity laser-plasma interaction has attracted considerable interest for a number of years. The laser-plasma interaction is accompanied by generation of various charged particle beams. Results of simultaneous novel measurements of electron-induced photonuclear neutrons (photoneutron), which are a diagnostic of the laser-plasma interaction, are proposed to use for optimization of the laser-plasma ion generation. The proposed method is demonstrated by the laser irradiation with the intensity os 1$$times$$10$$^{21}$$ W/cm$$^{2}$$ on the metal foil target. The photoneutrons are measured by using NE213 liquid scintillation detectors. Heavy-ion signal is registered with the CR39 track detector simultaneously. The measured signals of the electron-induced photoneutrons are well reproduced by using the Particle and Heavy Ion Transport code System (PHITS). The results obtained provide useful approach for analyzing the various laser based ion beams.

Journal Articles

Calculation of radiation shielding for laser-driven hadron beams therapeutic instrument

Sakaki, Hironao; Nishiuchi, Mamiko; Yogo, Akifumi; Bolton, P.; Hori, Toshihiko; Kondo, Kiminori; Saito, Fumihiro; Ueno, Masayuki; Takahashi, Hiroki; Iwase, Hiroshi*; et al.

Proceedings of 1st International Particle Accelerator Conference (IPAC '10) (Internet), p.94 - 96, 2010/05

The concept of a compact ion particle accelerator has become attractive in view of recent progress in laser-driven hadrons acceleration. The Photo Medical Research Centre (PMRC) of JAEA was established to address the challenge of laser-driven ion accelerator development for hadrons therapeutic. In the development of the instrument, it is necessary to do the bench-mark of the amount of the different types of radiation by the simulation code for shielding. The Monte Carlo Particle and Heavy Ion Transport code (PHITS) was used for bench-mark the dose on laser-shot radiations of short duration. The code predicts reasonably well the observed total dose as measured with a glass dosimeter in the laser-driven radiations.

Journal Articles

PHITS; Benchmark of partial charge-changing cross sections for intermediate-mass systems

Mancusi, D.*; Sihver, L.*; Gustafsson, K.*; La Tessa, C.*; Guetersloh, S.*; Zeitlin, C.*; Miller, J.*; Heilbronn, L.*; Niita, Koji*; Sato, Tatsuhiko; et al.

Nuclear Instruments and Methods in Physics Research B, 254(1), p.30 - 38, 2007/01

 Times Cited Count:17 Percentile:73.65(Instruments & Instrumentation)

The PHITS code is a three-dimensional Monte Carlo code that is able to simulate the transport of nuclei and other particles in complicated geometries. As a part of a comprehensive benchmarking program, we have investigated the possibility of using PHITS to calculate partial charge-changing cross sections and we have compared the results with measurements. The results suggest that the current reaction-cross-section models might be inadequate for use in space radiation protection: We therefore claim the need for a thorough benchmarking of the models and for new reaction-cross-section measurements and experimental techniques.

Journal Articles

Gamow-Teller decay of the $$T=1$$ nucleus $$^{46}$$Cr

Onishi, Takeo*; Gelberg, A.*; Sakurai, Hiroyoshi*; Yoneda, Kenichiro*; Aoi, Nori*; Imai, Nobuaki*; Baba, Hidetada*; Von Brentano, P.*; Fukuda, Naoki*; Ichikawa, Yuichi*; et al.

Physical Review C, 72(2), p.024308_1 - 024308_7, 2005/08

 Times Cited Count:21 Percentile:77.62(Physics, Nuclear)

no abstracts in English

JAEA Reports

None

Maruyama, Makoto*; Toriihara, Makoto*; Mikami, Tetsuji*; Hata, Koji*

JNC TJ7400 2005-030, 106 Pages, 2003/02

JNC-TJ7400-2005-030.PDF:50.79MB

no abstracts in English

JAEA Reports

Mechanical integrity of floor liner in secondary heat transport system cells of Monju

; ; Ueno, Fumiyoshi; ; ; ;

JNC TN2400 2000-005, 103 Pages, 2000/12

JNC-TN2400-2000-005.pdf:3.98MB

Inelastic analyses of the floor liner subjected to thermal loading due to sodium leakage and combustion were carried out, considering thinning of the liner plate due to molten salt type corrosion. Because the inelastic strain obtained by the analyses stayed below the ductility limit of the material, mechanical integrity, i.e., there exist no through-wall crack on the floor liner, was confirmed. Partial structural model tests were conducted, with a band of local thinning of the liner plate. Displacements were controlled to give specimens much larger strains than those obtained by the inelastic analyses above. No through-wall crack was observed by these tests. Mechanical integrity of the floor liner was confirmed by these results of the inelastic analyses and the partial structural model tests.

Journal Articles

Defect production and recovery in high-Tc superconductors irradiated with electrons and ions at low temperature

Ishikawa, Norito; Chimi, Yasuhiro; Iwase, Akihiro; *; Michikami, Osamu*

Journal of Nuclear Materials, 258-263, p.1924 - 1928, 1998/00

 Times Cited Count:9 Percentile:60.32(Materials Science, Multidisciplinary)

no abstracts in English

Journal Articles

Defect production and annealing in high-Tc superconductor EuBa$$_{2}$$Cu$$_{3}$$Oy irradiated with energetic ions at low temperature

Ishikawa, Norito; Chimi, Yasuhiro; Iwase, Akihiro; *; Michikami, Osamu*

Mat. Res. Soc. Symp. Proc., 504, p.171 - 175, 1998/00

no abstracts in English

Journal Articles

Electronic excitation effects in ion-irradiated high-Tc superconductors

Ishikawa, Norito; Chimi, Yasuhiro; Iwase, Akihiro; Maeta, Hiroshi; *; Michikami, Osamu*; Kambara, Tadashi*; *; *; Terasawa, M.*

Nuclear Instruments and Methods in Physics Research B, 135, p.184 - 189, 1998/00

 Times Cited Count:15 Percentile:74.74(Instruments & Instrumentation)

no abstracts in English

Journal Articles

High energy heavy ion irradiation damage in oxide superconductor EuBa$$_{2}$$Cu$$_{3}$$O$$_{y}$$

Iwase, Akihiro; Ishikawa, Norito; Chimi, Yasuhiro; Wakana, Hironori*; Michikami, Osamu*; Kambara, Tadashi*; *

Nuclear Instruments and Methods in Physics Research B, 146(1-4), p.557 - 564, 1998/00

 Times Cited Count:20 Percentile:81.43(Instruments & Instrumentation)

no abstracts in English

34 (Records 1-20 displayed on this page)