Refine your search:     
Report No.
 - 
Search Results: Records 1-8 displayed on this page of 8
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Structural design for intermediate heat exchanger of the HTTR

Kunitomi, Kazuhiko; Takeda, Takeshi; Shinozaki, Masayuki; Okubo, Minoru; *; Koikegami, Hajime*

Nihon Genshiryoku Gakkai-Shi, 37(4), p.316 - 326, 1995/00

 Times Cited Count:1 Percentile:17.52(Nuclear Science & Technology)

no abstracts in English

Journal Articles

Development of designing method for intermediate heat exchanger in the HTTR

Kunitomi, Kazuhiko; Shinozaki, Masayuki; Okubo, Minoru; Koikegami, Hajime*; *

Proc. of ARS 94 Int. Topical Meeting on Advanced Reactors Safety,Vol. 1, 0, p.188 - 192, 1994/00

no abstracts in English

JAEA Reports

MONJU Primary prototype pump test

*; *; *; *; *

PNC TN941 85-79, 157 Pages, 1985/05

PNC-TN941-85-79.pdf:3.61MB

In-sodium test was carried out for MONJU primary prototype pump, having a new hydrostatic bearing and convection suppressing fin. The test parameters were sodium level in the pump and flow of the seal gas. The test results are summarized as follows. (1)The pump operated satisfactorily on each condition of low sodium level with and without seal gas and normal sodium level without seal gas. This shows the pump has the soundness even in the cases of primary piping broken and the seal gas stopped. (2)It was obtained from the low sodium level test that each time of radial temperature difference for both inner and outer casings was its maximum and stable respectively. (3)It was approved that the maximum radial temperature differences for both inner and outer casings were increased with the time passing and sodium level falling, and also approved that the time which the temperature differences became their maximum were short with sodium level falling. (4)Maximum displacement of outer casing was smaller than the approved value at the lowest sodium level test, so it seems there is no problem on the real pump operation. (5)The test showed that convection suppressing fin was useful why the displacement of the casings were suppressed, because the times of the maximum radial temperature differences of the casings were late and displacement of outer casing was increased slowly. (6)It was approved that the pony motor of the pump was stopped and started again satisfactorily at the lowest sodium level.

JAEA Reports

MONJU Primgry prototype pump test; In-sodium preparatory testing at emergency sodium level

*; *; *; *; *; *

PNC TN941 84-154, 155 Pages, 1984/11

PNC-TN941-84-154.pdf:14.65MB

This report describes the operation test at emergency sodium level (up to 1230mm above impeller) of MONJU primary proto-type pump. The operation test is a preparatory test of "in-sodium test at emergency sodium level" that is performed after mounting convection suppressing rib for emergency sodium level. The following results were obtained: (1)At emergency level operation, temperature variations of outer casing circumferential direction increased, comparing at normal level operation. (2)At emergency level operation, temperature variations of inner casing circumferential direction were almostly same as that at the normal level operation, so inner casing displacement was little at emergency level operation. (3)The reaching time of maximum temperature variations and steady states from start of sodium level dropping were confirmed. (4)We evaluated the phenomena of natural convection in the vertical annulus from the test results of outer and inner casing temperature variations. (5)Measured and analyzed values of outer casing displacement were compared, analyzed values agreed approximately with measured values. Since the results as described above, we performed parameters surveying (temperature variations in cover gas region and casing dis placement) in transmission state from normal level operation to emergency level operation. We will plan "in-sodium test of emergency sodium level" that will be performed in long time operation and will confirm integrity of MONJU primary pump.

JAEA Reports

MONJU Primary prototype pump test; Pony motor system performance test

; *; *; Aoki, Tadao; *; *

PNC TN941 82-216, 62 Pages, 1982/09

PNC-TN941-82-216.pdf:2.57MB

This report describes the performance test of pony motor system mounted on the MONJU primary prototype pump. The test was conducted under various operation modes, and the following results were obtained: (1)The transition from the main motor to the pony motor was achieved very smoothly. (2)The transmission of the pony motor system worked well with its speed and torque kept constant. (3)start-up of a pump with a pony motor was accomplished very smoothly. (4)Apony motor current was about 63$$sim$$65% of it rated operation. (5)A characteristics of pony motor system in high temperature atomosphere remained as same as that in the room temperature. (6)The amplitude of pony motor bearing vibration during operation was a little.

Oral presentation

Demonstration of high peak power, high contrast OPCPA/Ti:sapphire hybrid laser system

Kiriyama, Hiromitsu; Mori, Michiaki; Nakai, Yoshiki; Shimomura, Takuya; Tanoue, Manabu*; Okada, Hajime; Kondo, Shuji; Kanazawa, Shuhei; Sagisaka, Akito; Daito, Izuru; et al.

no journal, , 

We have demonstrated over 30 J broadband output energy based on optical parametric chirped-pulse amplification (OPCPA) and Ti:sapphire chirped-pulse amplification (CPA), indicating potential for peak power of 500 TW with extremely high temporal contrast.

Oral presentation

Experimental evidences of light's orbital angular momentum carried by helical undulator harmonics

Sasaki, Shigemi*; Miyamoto, Atsushi*; Hosaka, Masahito*; Yamamoto, Naoto*; Kyo, Ayataro*; Kato, Masahiro*; Imazono, Takashi; Koike, Masato

no journal, , 

The phenomenon of higher harmonic radiation from a helical undulator carrying orbital angular momentum (OAM) attracts a great deal of attention because this novel property may be used as a new probe for synchrotron radiation science that would be performed in diffraction limited light source facilities. Although a diffraction limited VUV and X-ray sources do not yet exist, the 750 MeV UVSOR-III is already a diffraction limited light source in the UV region. In this ring, a tandem-aligned double-APPLE undulator system is installed. Using this set-up, we observed spiral interference patterns between two different harmonic radiations with a scanning fiber multi-channel spectrometer and a CCD camera placed at the end of BL1U beamline. By these measurements, various interference patterns such as single, double, and triple spirals were observed which concur with the theoretical prediction for every mode in the right or left circular polarization.

Oral presentation

Nuclear structure studies of $$^{254}$$Es region by Coulomb excitation $$gamma$$-ray spectroscopy

Yanagihara, Rikuto; Ideguchi, Eiji*; Nishio, Katsuhisa; Orlandi, R.; Makii, Hiroyuki; Asai, Masato; Hirose, Kentaro; Tsukada, Kazuaki; Toyoshima, Atsushi; Sato, Tetsuya; et al.

no journal, , 

8 (Records 1-8 displayed on this page)