Refine your search:     
Report No.
 - 
Search Results: Records 1-16 displayed on this page of 16
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

High-sensitive XANES analysis at Ce L$$_{2}$$-edge for Ce in bauxites using transition-edge sensors; Implications for Ti-rich geological samples

Li, W.*; Yamada, Shinya*; Hashimoto, Tadashi; Okumura, Takuma*; Hayakawa, Ryota*; Nitta, Kiyofumi*; Sekizawa, Oki*; Suga, Hiroki*; Uruga, Tomoya*; Ichinohe, Yuto*; et al.

Analytica Chimica Acta, 1240, p.340755_1 - 340755_9, 2023/02

 Times Cited Count:2 Percentile:31.9(Chemistry, Analytical)

no abstracts in English

Journal Articles

Dynamical response of transition-edge sensor microcalorimeters to a pulsed charged-particle beam

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I.-H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

IEEE Transactions on Applied Superconductivity, 31(5), p.2101704_1 - 2101704_4, 2021/08

 Times Cited Count:1 Percentile:11.15(Engineering, Electrical & Electronic)

A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.

Journal Articles

Deexcitation dynamics of muonic atoms revealed by high-precision spectroscopy of electronic $$K$$ X rays

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I. H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

Physical Review Letters, 127(5), p.053001_1 - 053001_7, 2021/07

 Times Cited Count:13 Percentile:79.44(Physics, Multidisciplinary)

We observed electronic $$K$$X rays emitted from muonic iron atoms using a superconducting transition-edge-type sensor microcalorimeter. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic $$K$$$$alpha$$ and $$K$$$$beta$$ X rays together with the hypersatellite $$K$$$$alpha$$ X rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the $$L$$-shell electrons, accompanied by electron side-feeding. Assisted by a simulation, this data clearly reveals the electronic $$K$$- and $$L$$-shell hole production and their temporal evolution during the muon cascade process.

Journal Articles

First observation of a nuclear $$s$$-state of a $$Xi$$ hypernucleus, $$^{15}_{Xi}{rm C}$$

Yoshimoto, Masahiro*; Fujita, Manami; Hashimoto, Tadashi; Hayakawa, Shuhei; Ichikawa, Yudai; Ichikawa, Masaya; Imai, Kenichi*; Nanamura, Takuya; Naruki, Megumi; Sako, Hiroyuki; et al.

Progress of Theoretical and Experimental Physics (Internet), 2021(7), p.073D02_1 - 073D02_19, 2021/07

 Times Cited Count:13 Percentile:81.3(Physics, Multidisciplinary)

Journal Articles

J-PARC E07; Systematic study of double strangeness system with hybrid emulsion method

Yoshida, Junya; Akaishi, Takaya; Fujita, Manami; Hasegawa, Shoichi; Hashimoto, Tadashi; Hosomi, Kenji; Ichikawa, Masaya; Ichikawa, Yudai; Imai, Kenichi*; Kim, S.; et al.

JPS Conference Proceedings (Internet), 33, p.011112_1 - 011112_8, 2021/03

Journal Articles

Electron-tracking Compton camera imaging of technetium-95m

Hatsukawa, Yuichi*; Hayakawa, Takehito*; Tsukada, Kazuaki; Hashimoto, Kazuyuki*; Sato, Tetsuya; Asai, Masato; Toyoshima, Atsushi; Tanimori, Toru*; Sonoda, Shinya*; Kabuki, Shigeto*; et al.

PLOS ONE (Internet), 13(12), p.e0208909_1 - e0208909_12, 2018/12

AA2018-0639.pdf:2.39MB

 Times Cited Count:3 Percentile:30.05(Multidisciplinary Sciences)

Imaging of $$^{95m}$$Tc radioisotope was conducted using an electron tracking-Compton camera (ETCC). $$^{95m}$$Tc emits 204, 582, and 835 keV $$gamma$$ rays, and was produced in the $$^{95}$$Mo(p,n)$$^{95m}$$Tc reaction with a $$^{95}$$Mo-enriched target. The recycling of the $$^{95}$$Mo-enriched molybdenum trioxide was investigated, and the recycled yield of $$^{95}$$Mo was achieved to be 70% - 90%. The images were obtained with each of the three $$gamma$$ rays. Results showed that the spatial resolution increases with increasing $$gamma$$-ray energy, and suggested that the ETCC with high-energy $$gamma$$-ray emitters such as $$^{95m}$$Tc is useful for the medical imaging of deep tissue and organs in the human body.

Journal Articles

Production of $$^{rm 95m}$$Tc for Compton camera imaging

Hatsukawa, Yuichi; Hashimoto, Kazuyuki; Tsukada, Kazuaki; Sato, Tetsuya; Asai, Masato; Toyoshima, Atsushi; Nagai, Yasuki; Tanimori, Toru*; Sonoda, Shinya*; Kabuki, Shigeto*; et al.

Journal of Radioanalytical and Nuclear Chemistry, 303(2), p.1283 - 1285, 2015/02

 Times Cited Count:2 Percentile:17.57(Chemistry, Analytical)

Technetium-99m ($$^{rm 99m}$$Tc) is used in radioactive medical diagonostic tests, for example as a radioactive tracer that medical equipment can detect in the human body. It is well suited to the role because it emits readily detectable 141 keV $$gamma$$ rays, and its half-life is 6.01 hours (meaning that about 94% of it decays to technetium-99 in 24 hours). There are at least 31 commonly used radiopharmaceuticals based on technetium-99m for imaging and functional studies of the brain, myocardium, thyroid, lungs, liver, gallbladder, kidneys, skeleton, blood, and tumors. Recent years, with the develop-ment of the Compton camera which can realize high position resolution, technetium isotopes emitting high energy $$gamma$$-rays are required. In this study, technetium-95m which emits some $$gamma$$ rays around 800 keV was produced by the $$^{95}$$Mo(p,n)$$^{rm 95m}$$Tc reaction.

Journal Articles

Symmetric diblock copolymer thin films on rough substrates; Microdomain periodicity in pure and blended films

Sivaniah, E.*; Matsubara, Shinya*; Zhao, Y.; Hashimoto, Takeji; Fukunaga, Kenji*; Kramer, E. J.*; Mates, T. E.*

Macromolecules, 41(7), p.2584 - 2592, 2008/04

 Times Cited Count:36 Percentile:71.09(Polymer Science)

JAEA Reports

Construction and magnetic field measurement of quasi-periodic undulator

Kobayashi, Hideki*; *; Sasaki, Shigemi; Shimada, Taihei; Takao, Masaru*; *;

JAERI-Tech 96-014, 14 Pages, 1996/03

JAERI-Tech-96-014.pdf:0.75MB

no abstracts in English

Journal Articles

Conceptual design of quasiperiodic undulator

Sasaki, Shigemi; Kobayashi, Hideki*; Takao, Masaru*; ; *

Review of Scientific Instruments, 66(2), p.1953 - 1955, 1995/02

 Times Cited Count:12 Percentile:69.05(Instruments & Instrumentation)

no abstracts in English

JAEA Reports

JAEA Reports

Calculations of thermal deformations in directly water-cooled monochromator crystals

*; *; Motohashi, Haruhiko

JAERI-M 93-021, 20 Pages, 1993/02

JAERI-M-93-021.pdf:0.79MB

no abstracts in English

Journal Articles

Novel use of anomalous scattering of synchrotron radiation for local atomic order in a disordered ternary alloy

*; *

Radiation Effects and Defects in Solids,Vol. 124, p.147 - 171, 1992/00

no abstracts in English

Oral presentation

Production of $$^{95m}$$Tc for Compton camera imaging

Hatsukawa, Yuichi; Tsukada, Kazuaki; Hashimoto, Kazuyuki; Sato, Tetsuya; Asai, Masato; Toyoshima, Atsushi; Nagai, Yasuki; Tanimori, Toru*; Sonoda, Shinya*; Kabuki, Shigeto*; et al.

no journal, , 

In recent years, the Compton camera which is originally developed for the astrophysical studies was applied for medical diagnostic usage. For the Compton camera imaging require technetium isotopes emitting higher energy $$gamma$$-rays. Two Tc isotopes, $$^{95m}$$Tc (T$$_{1/2}$$ = 60 d; E$$gamma$$ = 204, 582 and 835 keV) and $$^{96}$$Tc(T$$_{1/2}$$ = 4.28 d, E$$gamma$$ = 778 and 812 keV) are candidates for Compton camera imaging. Compton camera imaging can realize high position resolution without collimator. Because of no collimator using, the Compton camera makes higher $$gamma$$-ray detection efficiency. Compared with SPECT with $$^{99m}$$Tc, the Compton camera imaging technique can be expected that radiation exposure deduce to 1/5-1/10. In this study, technetium-95m was produced by the $$^{95}$$Mo(p,n)$$^{95m}$$Tc reaction.

Oral presentation

Analysis of uranium in environmental samples by micro X-ray fluorescence spectroscopy using transition edge sensors

Yomogida, Takumi; Yamada, Shinya*; Ichinohe, Yuto*; Sato, Toshiki*; Hayakawa, Ryota*; Okada, Shinji*; Toyama, Yuichi*; Hashimoto, Tadashi; Noda, Hirofumi*; Isobe, Tadaaki*; et al.

no journal, , 

Biotite is known as a host phase that retains uranium (U) in uranium deposits at Ningyo-Toge and Tono, and it is expected that the distribution of U in biotite will provide insight into the concentration and long-term immobilization of U. However, biotite contains rubidium (Rb), which interferes with X-ray fluorescence analysis, making it difficult to accurately determine the distribution of U-Rb in biotite by measurement using a conventional solid state detector (SSD). In this study, we developed a method to use a transition edge sensor (TES) as a detector in microbeam X-ray fluorescence analysis, which enables us to detect X-ray fluorescence with an energy resolution of about 20 eV and to obtain a Rb K$$alpha$$ line at 13.373 keV and a U L$$alpha$$ line at 13.612 keV can be completely separated. Therefore,the developed method enables us to accurately determine the distribution of U-Rb in biotite.

Oral presentation

Elucidation of the reduction of uranium in biotite by advanced X-ray spectroscopy

Yomogida, Takumi; Yamada, Shinya*; Ichinohe, Yuto*; Sato, Toshiki*; Hayakawa, Ryota*; Okada, Shinji*; Toyama, Yuichi*; Hashimoto, Tadashi; Noda, Hirofumi*; Isobe, Tadaaki*; et al.

no journal, , 

The reduction of uranium on biotite was studied to obtain insight into the immobilization of uranium in the environment. The chemical species of uranium in biotite were studied using a superconducting transition edge sensor and an X-ray emission spectrometer to remove interference from rubidium in biotite. As a result, the speciation of uranium in biotite collected from former uranium deposits was possible. The XANES spectra of the biotite indicated that the uranium in the biotite was partially reduced.

16 (Records 1-16 displayed on this page)
  • 1