Yutani, Toshiaki*; *; *
PNC TJ9124 90-003, 97 Pages, 1990/09
Corrosion tests with tellurium and iodine were conducted at 500, 600 and 700C for 100 hours, to evaluate corrosion resistance to fission products. Domestic oxide dispersion strengthened ferritic steel tubes (13Cr-0.5YO-0.5Ti-3W steel and 11Cr-0.25YO-0.5Ti-2W steel), high strengthened ferritic/martensitic steel tube (1FK) and modified SUS316 stainless steel tube were tested. The results were summarized as follows. (1)13Cr-0.5YO-0.5Ti-3W steel was superior to and 11Cr-0.25YO-0.5Ti-2W steel and 1FK were inferior to the modified SUS316 stainless steel in corrosion resistance to tellurium at 700C. (2)It was recognized that corrosion resistance to tellurium improved with chromium content at 500 and 600C. (3)All steel specimens had the highest weight losses at 600C in the corrosion tests by iodine. (4)13Cr-0.5Y0-0.5Ti-3W steel, 11Cr-0.25YO-0.5Ti-2W steel and 1FK were inferior to the modified SUS316 stainless steel in corrosion resistance to iodine at 600C.
Ukai, Shigeharu; *; *; Enokido, Yuji
Journal of Nuclear Materials, 149(3), p.209 - 218, 1987/00
None
*; ; ; ; *
JAERI-M 9140, 40 Pages, 1980/10
no abstracts in English
; ; ; ; *
JAERI-M 7796, 85 Pages, 1978/08
no abstracts in English