Refine your search:     
Report No.
 - 
Search Results: Records 1-6 displayed on this page of 6
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of the external pressure charts of 2 $$^{1}/_{4}$$Cr-1Mo and Mod.9Cr-1Mo steel at elevated temperature design

Ando, Masanori; Okajima, Satoshi; Imo, Kazumichi*

Proceedings of 2019 ASME Pressure Vessels and Piping Conference (PVP 2019) (Internet), 7 Pages, 2019/07

For the required thickness estimation against buckling in the elevated temperature design, the external pressure chart for two kinds of ferritic steel, 2 $$^{1}/_{4}$$Cr-1Mo and Mod.9Cr-1Mo steel, was developed. On the basis of the guideline described in the ASME BPVC Section II, Part D, Mandatory Appendix 3 with mechanical and physical properties provided in the JSME fast reactor code, the external pressure charts for each material were constructed. As the result, three external pressure charts with digital values were proposed for elevated temperature design. And the rationalization effect from the current alternative using was evaluated by the sample problem. This proposal resolves the two issues. One is alternative use of inferior material strength chart over the 150$$^{circ}$$C. The other is the external pressure chart above 480$$^{circ}$$C for these ferritic steels are not available.

JAEA Reports

Evaluation of mechanical integrity of floor liner in secondary heat transport system cells of Monju

Imo, Kazumichi; Onuki, Koji; Kikuchi, H.; Morishita, Masaki; Igawa, Kenichi*; Nishibayashi, Yohei; Ikeda, Makinori

JNC TN2400 2003-004, 78 Pages, 2004/03

JNC-TN2400-2003-004.pdf:4.74MB

About the secondary system floor liner of Monju, the mechanical soundness of a floor liner to the thermal load conditions by combustion of leak sodium was evaluated by large displacement inelastic analysis and the partial structure model test.In large displacement inelastic analysis, it was confirmed that heat strain of a floor liner was less than the standard value of the strain for no through-wall crack. In addition, the influence evaluation by a temperature increasing rate, liner board thickness, and the existence of corrosion thinning was performed. The result, the influence on the maximum strain was small in any parameter.In the partial structure model test, even when a strain more excessive than the standard value of strain was given, it was confirmed no through-wall crack in a liner plate.In addition, this report improves the evaluation conditions of the conventional research report [1], and resummarizes them to detailed design evaluation.

JAEA Reports

The Evaluation of thermal striping damages in temperature fluctuations

Sukekawa, Masayuki*; Imo, Kazumichi*; Kawakami, Mitsuo*

JNC TJ9430 2001-002, 98 Pages, 2002/03

JNC-TJ9430-2001-002.pdf:2.68MB

None

Oral presentation

Construction of external pressure charts for $$2frac{1}{4}$$Cr-1Mo steel and Mod. 9Cr-1Mo steel at elevated temperature

Okajima, Satoshi; Imo, Kazumichi*

no journal, , 

no abstracts in English

Oral presentation

Effect of aging and creep damage on mechanical strength of Mod. 9Cr-1Mo steel

Kanayama, Hideyuki; Nagae, Yuji; Onizawa, Takashi; Wakai, Takashi; Imo, Kazumichi*

no journal, , 

no abstracts in English

Oral presentation

Capability study on robustness improvement using the maintenance cooling system in MONJU, 2; Seismic response analysis of preheating system

Matsui, Kazuaki; Imo, Kazumichi*; Mitsumoto, Rika; Ando, Masanori; Futagami, Satoshi

no journal, , 

no abstracts in English

6 (Records 1-6 displayed on this page)
  • 1