Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 149

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of nondestructive elemental analysis system for Hayabusa2 samples using muonic X-rays

Osawa, Takahito; Nagasawa, Shunsaku*; Ninomiya, Kazuhiko*; Takahashi, Tadayuki*; Nakamura, Tomoki*; Wada, Taiga*; Taniguchi, Akihiro*; Umegaki, Izumi*; Kubo, Kenya*; Terada, Kentaro*; et al.

ACS Earth and Space Chemistry (Internet), 7(4), p.699 - 711, 2023/04

 Times Cited Count:4 Percentile:93.95(Chemistry, Multidisciplinary)

The concentrations of carbon and other major elements in asteroid samples provide very important information on the birth of life on the Earth and the solar-system evolution. Elemental analysis using muonic X-rays is one of the best analytical methods to determine the elemental composition of solid materials, and notably, is the only method to determine the concentration of light elements in bulk samples in a non-destructive manner. We developed a new analysis system using muonic X-rays to measure the concentrations of carbon and other major elements in precious and expectedly tiny samples recovered from the asteroid Ryugu by spacecraft Hayabusa2. Here we report the development process of the system in 4 stages and their system configurations, The analysis system is composed of a stainless-steel analysis chamber, an acrylic glove box for manipulating asteroid samples in a clean environment, and Ge semiconductor detectors arranged to surround the analysis chamber. The performance of the analysis system, including the background level, which is crucial for the measurement, was greatly improved from the first stage to the later ones. Our feasibility study showed that the latest model of our muonic X-ray analysis system is capable of determining the carbon concentration in Hayabusa2's sample model with an uncertainty of less than 10 percent in a 6-day measurement.

Journal Articles

Design and actual performance of J-PARC 3 GeV rapid cycling synchrotron for high-intensity operation

Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.

Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09

 Times Cited Count:6 Percentile:84.97(Nuclear Science & Technology)

In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.

Journal Articles

Dynamical response of transition-edge sensor microcalorimeters to a pulsed charged-particle beam

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I.-H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

IEEE Transactions on Applied Superconductivity, 31(5), p.2101704_1 - 2101704_4, 2021/08

 Times Cited Count:1 Percentile:11.15(Engineering, Electrical & Electronic)

A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.

Journal Articles

Deexcitation dynamics of muonic atoms revealed by high-precision spectroscopy of electronic $$K$$ X rays

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I. H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

Physical Review Letters, 127(5), p.053001_1 - 053001_7, 2021/07

 Times Cited Count:13 Percentile:79.44(Physics, Multidisciplinary)

We observed electronic $$K$$X rays emitted from muonic iron atoms using a superconducting transition-edge-type sensor microcalorimeter. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic $$K$$$$alpha$$ and $$K$$$$beta$$ X rays together with the hypersatellite $$K$$$$alpha$$ X rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the $$L$$-shell electrons, accompanied by electron side-feeding. Assisted by a simulation, this data clearly reveals the electronic $$K$$- and $$L$$-shell hole production and their temporal evolution during the muon cascade process.

Journal Articles

Reduction and resource recycling of high-level radioactive wastes through nuclear transmutation; Isolation techniques of Pd, Zr, Se and Cs in simulated high level radioactive waste using solvent extraction

Sasaki, Yuji; Morita, Keisuke; Ito, Keisuke; Suzuki, Shinichi; Shiwaku, Hideaki; Takahashi, Yuya*; Kaneko, Masaaki*; Omori, Takashi*; Asano, Kazuhito*

Proceedings of International Nuclear Fuel Cycle Conference (GLOBAL 2017) (USB Flash Drive), 4 Pages, 2017/09

no abstracts in English

Journal Articles

Extraction and separation of Se, Zr, Pd, and Cs including long-lived radionuclides

Sasaki, Yuji; Morita, Keisuke; Suzuki, Shinichi; Shiwaku, Hideaki; Ito, Keisuke; Takahashi, Yuya*; Kaneko, Masaaki*

Solvent Extraction Research and Development, Japan, 24(2), p.113 - 122, 2017/06

The solvent extraction of Se, Zr, Pd, and Cs from nitric acid into 1-octanol (OC) and dodecane has been performed. These elements include long-lived radionuclides in spent nuclear fuels, so a simple separation method is indispensable for the development of the treatment of high-level liquid radioactive waste. It was found that Se can be extracted using phenylenediamine, Zr can be extracted using tetraoctyl diglycolamide and di-2-ethylhexyl phosphoric acid, and Pd can be extracted using (methylimino)bis(dioctylacetamide) and hexaoctylnitrilotriacetamide. These elements can be recovered in over 90% yield by these extractants from nitric acid into OC. A distribution ratio of Cs of greater than 1 can be obtained using di-t-butyldibenzo-18-crown-6. It is clear that 90% recovery of Cs can be achieved using an extraction solvent with ten times the volume of the aqueous phase.

Journal Articles

Development of a control system at a 3 MeV linac in J-PARC

Sawabe, Yuki*; Ishiyama, Tatsuya; Takahashi, Daisuke; Kato, Yuko; Suzuki, Takahiro*; Hirano, Koichiro; Takei, Hayanori; Meigo, Shinichiro; Kikuzawa, Nobuhiro; Hayashi, Naoki

Proceedings of 13th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.647 - 651, 2016/11

In the J-PARC, a 3 MeV linac has been developed for the tests of beam scraper irradiation and charge exchange by high-power laser. To accomplish tests efficiently and safely, the control system for 3 MeV was designed and developed, and this system consists of four subsystems, personal protection system, machine protection system, timing system, and remote control system using the EPICS. In this paper, the details of control system for a 3 MeV linac are presented.

JAEA Reports

Development of ITER CODAC compatible gyrotron local control system and its operation

Oshima, Katsumi; Oda, Yasuhisa; Takahashi, Koji; Terakado, Masayuki; Ikeda, Ryosuke; Hayashi, Kazuo*; Moriyama, Shinichi; Kajiwara, Ken; Sakamoto, Keishi

JAEA-Technology 2015-061, 65 Pages, 2016/03

JAEA-Technology-2015-061.pdf:24.28MB

In JAEA, an ITER relevant control system for ITER gyrotron was developed according to Plant Control Design Handbook. This control system was developed based on ITER CODAC Core System and implemented state machine control of gyrotron operation system, sequential timing control of gyrotron oscillation startup, and data acquisition. The operation of ITER 170 GHz gyrotron was demonstrated with ITER relevant power supply configuration. This system is utilized for gyrotron operation test for ITER procurement. This report describes the architecture of gyrotron operation system, its basic and detailed design, and recent operation results.

JAEA Reports

Current status of a decommissioning project in the Enrichment Engineering Facilities; Results in the first-half of the fiscal year of 2014

Matsumoto, Takashi; Morimoto, Yasuyuki; Takahashi, Nobuo; Takata, Masaharu; Yoshida, Hideaki; Nakashima, Shinichi; Ishimori, Yuu

JAEA-Technology 2015-036, 60 Pages, 2016/01

JAEA-Technology-2015-036.pdf:9.15MB

The Enrichment Engineering Facilities of the Ningyo-toge Environmental Engineering Center was constructed in order to establish the technical basis of the uranium enrichment plant in Japan. Uranium enrichment tests, using natural and reprocessed uranium, were carried out from 1979 to 1990 at two types of plants in the facilities. UF$$_{6}$$ handling equipment and Supplemental equipment in these plants are intended to be dismantled by 2019 in order to make places for future projects, for example, inventory investigation, precipitation treatment, etc. This report shows the basic plan of this decommissioning project and presents the current state of dismantling in the first-half of the fiscal year of 2014, with indicating its schedule, procedure, situation, results, and so on. The dismantled materials generated amounted to 37 mesh containers and 199 drums, and the secondary waste generated amounted to 271.4 kg.

Journal Articles

Progress and status of the gyrotron development for the JT-60SA ECH/CD system

Kobayashi, Takayuki; Sawahata, Masayuki; Terakado, Masayuki; Hiranai, Shinichi; Ikeda, Ryosuke; Oda, Yasuhisa; Wada, Kenji; Hinata, Jun; Yokokura, Kenji; Hoshino, Katsumichi; et al.

Proceedings of 40th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz 2015) (USB Flash Drive), 3 Pages, 2015/08

A gyrotron for electron cyclotron heating and current drive (ECH/CD) has been developed for JT-60SA (Super-Advanced). In high-power, long-pulse operations, oscillations of 1 MW/100 s have been demonstrated at both 110 GHz and 138 GHz, for the first time. These results fully satisfied the requirements for JT-60SA. Moreover, it was experimentally shown that the higher power operation at each frequency is expected to be acceptable for this gyrotron from the viewpoint of heat load at the cavity resonator, collector, and stray radiation absorbers. An oscillation at 82 GHz, which is an additional frequency, has been demonstrated up to 2 s at the output power of 0.4 MW, so far. High power experiments toward higher power of 1.5 MW (110/138 GHz) and 1 MW (82 GHz) are ongoing.

Journal Articles

Study on heat transfer mechanism elucidation during pool nucleate boiling by measuring instantaneous surface temperature distribution with infrared radiation camera

Koizumi, Yasuo; Takahashi, Kazuki*; Uesawa, Shinichiro; Yoshida, Hiroyuki; Takase, Kazuyuki

Dai-52-Kai Nihon Dennetsu Shimpojiumu Koen Rombunshu (CD-ROM), P. 2, 2015/06

Pool nucleate boiling heat transfer experiments were performed for water at 0.101 MPa to examine the elementary process of the nucleate boiling. The copper printed circuit board of a 1.57 mm thick bakelite plate coated with a 0.035 mm thick copper membrane was used for a heat transfer surface. The size of the heat transfer surface was 10 mm $$times$$ 10 mm. direct current was supplied to it to heat it up. The bakelite plate of the backside of the copper layer was taken by 7 mm $$times$$ 10 mm. The instantaneous variation of the backside temperature of the heat transfer surface was measured with an infrared radiation camera. The time and the space resolution of the infrared cameras used in experiments were 120 Hz and 0.315 mm $$times$$ 0.315 mm, respectively. Surface temperatures just before the burn-out measured with 120 Hz suggest that the surface temperature was steadily low at a large part of the heat transfer surface. A small hot-dry area came out at the critical heat flux condition. Then, this small hot-dry area iterated to expand and shrink and gradually grew. Other area was still wetted and kept at low temperature. Eventually the small hot-dry area started to grow continuously and a whole part of the heat transfer surface became hot-dry to reach the physical burn-out. The heat transfer surface was divided into two large areas; the hot-dry area and the low-temperature wetted area until the physical burn-out. The local surface heat flux variation derived from measured surface temperature variation clearly illustrated that the boundary between the dried area and the wetted area moved back and forth and the dried arear gradually grew to reach physical bourn-out at the critical heat flux condition.

Journal Articles

Gyrotron development for high-power, long-pulse electron cyclotron heating and current drive at two frequencies in JT-60SA and its extension toward operation at three frequencies

Kobayashi, Takayuki; Moriyama, Shinichi; Yokokura, Kenji; Sawahata, Masayuki; Terakado, Masayuki; Hiranai, Shinichi; Wada, Kenji; Sato, Yoshikatsu; Hinata, Jun; Hoshino, Katsumichi; et al.

Nuclear Fusion, 55(6), p.063008_1 - 063008_8, 2015/06

 Times Cited Count:25 Percentile:77.57(Physics, Fluids & Plasmas)

A gyrotron enabling high-power, long-pulse oscillations at both 110 GHz and 138 GHz has been developed for electron cyclotron heating (ECH) and current drive (CD) in JT-60SA. Oscillations of 1 MW for 100 s have been demonstrated at both frequencies, for the first time as a gyrotron operating at two frequencies. The optimization of the anode voltage, or the electron pitch factor, using a triode gun was a key to obtain high power and high efficiency at two frequencies. It was also confirmed that the internal losses in the gyrotron were sufficiently low for expected long pulse operation at the higher power level of $$sim$$1.5 MW. Another important result is that an oscillation at 82 GHz, which enables to use fundamental harmonic waves in JT-60SA while the other two frequencies are used as second harmonics waves, was demonstrated up to 0.4 MW for 2 s. These results of the gyrotron development significantly contribute to enhancing operation regime of the ECH/CD system in JT-60SA.

Journal Articles

Stabilization of a high-order harmonic generation seeded extreme ultraviolet free electron laser by time-synchronization control with electro-optic sampling

Tomizawa, Hiromitsu*; Sato, Takahiro*; Ogawa, Kanade*; Togawa, Kazuaki*; Tanaka, Takatsugu*; Hara, Toru*; Yabashi, Makina*; Tanaka, Hitoshi*; Ishikawa, Tetsuya*; Togashi, Tadashi*; et al.

High Power Laser Science and Engineering, 3, p.e14_1 - e14_10, 2015/04

 Times Cited Count:6 Percentile:34.43(Optics)

no abstracts in English

Journal Articles

Study on heat transfer surface temperature variation during pool nucleate boiling by measuring instantaneous surface temperature distribution with infrared radiation camera

Koizumi, Yasuo; Takahashi, Kazuki*; Uesawa, Shinichiro; Yoshida, Hiroyuki; Takase, Kazuyuki

Proceedings of 9th International Conference on Boiling and Condensation Heat Transfer (Boiling & Condensation 2015) (DVD-ROM), 10 Pages, 2015/04

Pool nucleate boiling heat transfer experiments were performed for water at 0.101 MPa to examine the elementary process of the nucleate boiling. The copper printed circuit board of a 1.57 mm thick Bakelite plate coated with a 0.035 mm thick copper membrane was used for a heat transfer surface. The size of the heat transfer surface was 10 mm $$times$$ 10 mm. Direct current was supplied to it to heat it up. The Bakelite plate of the backside of the copper layer was taken by 7 mm $$times$$ 10 mm. The instantaneous variation of the backside temperature of the heat transfer surface was measured with an infrared radiation camera. The time and the space resolution of the infrared cameras used in experiments were 120 Hz and 0.315 mm $$times$$ 0.315 mm, respectively. Surface temperatures just before the burn-out measured with 120 Hz suggest that the surface temperature was steadily low at a large part of the heat transfer surface. A small hot-dry area came out at the critical heat flux condition. Then, this small hot-dry area iterated to expand and shrink and gradually grew. Other area was still wetted and kept at low temperature. Eventually the small hot-dry area started to grow continuously and a whole part of the heat transfer surface became hot-dry to reach the physical burn-out. The heat transfer surface was divided into two large areas; the hot-dry area and the low-temperature-wetted area until the physical burn-out. The local surface heat flux variation derived from measured surface temperature variation clearly illustrated that the boundary between the dried area and the wetted area moved back and forth and the dried arear gradually grew to reach physical bourn-out at the critical heat flux condition.

Journal Articles

The Possible interplanetary transfer of microbes; Assessing the viability of ${it Deinococcus}$ spp. under the ISS environmental conditions for performing exposure experiments of microbes in the Tanpopo mission

Kawaguchi, Yuko*; Yang, Y.*; Kawashiri, Narutoshi*; Shiraishi, Keisuke*; Takasu, Masako*; Narumi, Issey*; Sato, Katsuya; Hashimoto, Hirofumi*; Nakagawa, Kazumichi*; Tanigawa, Yoshiaki*; et al.

Origins of Life and Evolution of Biospheres, 43(4-5), p.411 - 428, 2013/10

 Times Cited Count:41 Percentile:80.34(Biology)

Journal Articles

Full-coherent free electron laser seeded by 13th- and 15th-order harmonics of near-infrared femtosecond laser pulses

Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Togashi, Tadashi*; Fukami, Kenji*; et al.

Journal of Physics B; Atomic, Molecular and Optical Physics, 46(16), p.164006_1 - 164006_6, 2013/08

 Times Cited Count:3 Percentile:19.06(Optics)

By introducing 13th- (61.7 nm) and 15th-order harmonics (53.4 nm) of femtosecond laser pulses at 800 nm into an undulator of SCSS (SPring-8 Compact SASE Source) test accelerator at RIKEN, these harmonic pulses were amplified by a factor of more than 10$$^{2}$$ with a high contrast ratio through the interaction between accelerated electron bunches and the harmonic pulses. From numerical simulations of the amplification processes of high-order harmonic pulses in the undulator, optimum conditions of the electron bunch duration interacting with the high-order harmonic pulses were investigated for generating full-coherent and intense pulses in the extreme ultraviolet wavelength region.

Journal Articles

Full-coherent HHG-seeded EUV-FEL locked by EOS timing feedback

Ogawa, Kanade*; Sato, Takahiro*; Matsubara, Shinichi*; Okayasu, Yuichi*; Togashi, Tadashi*; Watanabe, Takahiro*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; et al.

Proceedings of 10th Conference on Lasers and Electro-Optics Pacific Rim and 18th OptoElectronics and Communications Conference and Photonics in Switching 2013 (CLEO-PR & OECC/PS 2013) (USB Flash Drive), 2 Pages, 2013/06

no abstracts in English

Journal Articles

Three-dimensional and multienergy $$gamma$$-ray simultaneous imaging by using a Si/CdTe Compton camera

Suzuki, Yoshiyuki*; Yamaguchi, Mitsutaka; Odaka, Hirokazu*; Shimada, Hirofumi*; Yoshida, Yukari*; Torikai, Kota*; Sato, Takahiro; Arakawa, Kazuo*; Kawachi, Naoki; Watanabe, Shigeki; et al.

Radiology, 267(3), p.941 - 947, 2013/06

 Times Cited Count:23 Percentile:65.03(Radiology, Nuclear Medicine & Medical Imaging)

Journal Articles

High intense full-coherent radiation of free electron laser seeded by high-order harmonics in extreme-ultraviolet region

Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Hara, Toru*; et al.

Proceedings of Ultrafast Optics IX (CD-ROM), 2 Pages, 2013/03

We have demonstrated free-electron laser radiation seeded by high-order harmonics in the extreme-ultraviolet region. Strong enhancement of the radiation intensity by a factor of 104 was observed with timing control of an electro-optical sampling technique.

Journal Articles

An Evaluation of three-dimensional imaging by use of Si/CdTe Compton cameras

Yamaguchi, Mitsutaka; Nagao, Yuto; Kawachi, Naoki; Fujimaki, Shu; Kamiya, Tomihiro; Odaka, Hirokazu*; Kokubun, Motohide*; Takeda, Shinichiro*; Watanabe, Shin*; Takahashi, Tadayuki*; et al.

Proceedings of 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 3 Pages, 2013/00

149 (Records 1-20 displayed on this page)