検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年

Commissioning results of the KSTAR neutral beam system

KSTAR用中性粒子入射システムの試運転結果

Bae, Y. S.*; Park, Y. M.*; Kim, J. S.*; Han, W. S.*; Kwak, S. W.*; Chang, Y. B.*; Park, H. T.*; Song, N. H.*; Chang, D. H.*; Jeong, S. H.*; Kim, T. S.*; Oh, B. H.*; Jin, J. T.*; In, S. R.*; Lee, K. W.*; Chang, D. S.*; Yang, H. L.*; Kwon, M.*; 渡邊 和弘; 大楽 正幸; 戸張 博之; 柏木 美恵子; 花田 磨砂也; 井上 多加志; Grisham, L.*

Bae, Y. S.*; Park, Y. M.*; Kim, J. S.*; Han, W. S.*; Kwak, S. W.*; Chang, Y. B.*; Park, H. T.*; Song, N. H.*; Chang, D. H.*; Jeong, S. H.*; Kim, T. S.*; Oh, B. H.*; Jin, J. T.*; In, S. R.*; Lee, K. W.*; Chang, D. S.*; Yang, H. L.*; Kwon, M.*; Watanabe, Kazuhiro; Dairaku, Masayuki; Tobari, Hiroyuki; Kashiwagi, Mieko; Hanada, Masaya; Inoue, Takashi; Grisham, L.*

中性粒子入射(NBI)システムは、韓国超伝導トカマク先進研究装置(KSTAR)における高性能運転と長パルス運転のためのイオン加熱と電流駆動を行うように設計された。KSTAR用NBIは2つのビームラインで構成されている。各々のビームラインはイオン源1台あたり最大ビームエネルギー120keVで重水素中性粒子ビームパワー2.5MW以上を入射できるよう設計されたイオン源を3台内蔵している。したがって、KSTAR用NBIシステムの最終目標は2つのビームラインで重水素中性粒子ビームパワー14MW以上の入射を目指している。NBIシステムの計画に則り、各々のコンポーネントとサブシステムの試運転を含めた2010年活動においては、最初のNBIシステムにより、KSTARトカマク・プラズマへ1台のイオン源からビーム入射を行うことである。この論文では、1台のイオン源を用いた最初のNBIシステムの建設と調整運転について紹介する。

The neutral beam injection (NBI) system is designed to provide the ion heating and current drive for the high performance operation and long pulse operation of the Korean Superconducting Tokamak Advanced Research (KSTAR). The KSTAR NBI consists of two beam lines. Each beam line contains three ion sources of which one ion source has been designed to deliver more than 2.5 MW of deuterium neutral beam power with maximum 120-keV beam energy. Consequently, the final goal of the KSTAR NBI system aims to inject more than 14 MW of deuterium beam power with the two beam lines. According to the planned NBI system, the first NBI system is to demonstrate the beam injection from one ion source into the KSTAR tokamak plasma in 2010 campaign including the system commissioning of each components and subsystems. In this paper, the construction and the commissioning of the first NBI system with one ion source is presented.

Access

:

- Accesses

InCites™

: