Corrosion behavior of F82H exposed to high temperature pressurized water with a rotating apparatus

回転試験装置を用いて高温高圧水中にばく露したF82Hの腐食特性

金井 亮彦*; 笠田 竜太*; 中島 基樹; 廣瀬 貴規; 谷川 尚; 榎枝 幹男; 小西 哲之*

Kanai, Akihiko*; Kasada, Ryuta*; Nakajima, Motoki; Hirose, Takanori; Tanigawa, Hisashi; Enoeda, Mikio; Konishi, Satoshi*

The present study reports the compatibility of a reduced-activation ferritic steel F82H exposed to high temperature pressurized water using a rotating disk apparatus at 573 K. Every rotated sample reduces their weight due to water flow. Cross-sectional observations revealed that difference of apparent rotating speed on the microstructural change is limited.