検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 39 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Simultaneous measurement of neutron-induced fission and capture cross sections for $$^{241}$$Am at neutron energies below fission threshold

廣瀬 健太郎; 西尾 勝久; 牧井 宏之; 西中 一朗*; 太田 周也*; 永山 達郎*; 田村 信行*; 後藤 真一*; Andreyev, A. N.; Vermeulen, M. J.; et al.

Nuclear Instruments and Methods in Physics Research A, 856, p.133 - 138, 2017/06

 被引用回数:5 パーセンタイル:44.54(Instruments & Instrumentation)

Fission and capture reactions were simultaneously measured in the neutron-induced reactions of $$^{241}$$Am at J-PARC. Data were taken with the TOF method in $$E_n$$ = 0.1$$sim$$20 eV. The fission events were observed by detecting prompt fission neutrons using liquid organic scintillators. The capture reaction was measured by detecting $$gamma$$ rays from the compound nuclei using the same detectors, where the prompt fission neutrons and capture $$gamma$$ rays were separated by a pulse shape analysis. The cross sections were obtained by normalizing the relative yields at the first resonance to evaluations or other experimental data. The ratio of the fission to capture cross sections at each resonance is compared with those from an evaluated nuclear data library and other experimental data. Some differences were found between the present values and the library/literature values at several resonances.

論文

Misassigned neutron resonances of $$^{142}$$Nd and stellar neutron capture cross sections

片渕 竜也*; 松橋 泰平*; 寺田 和司; 井頭 政之*; 水本 元治*; 廣瀬 健太郎; 木村 敦; 岩本 信之; 原 かおる*; 原田 秀郎; et al.

Physical Review C, 91(3), p.037603_1 - 037603_5, 2015/03

 被引用回数:8 パーセンタイル:50.7(Physics, Nuclear)

Time-of-flight spectra of the neutron capture events of $$^{142}$$Nd were measured using a spallation neutron source at the Japan Proton Accelerator Research Complex. The first six resonances of $$^{142}$$Nd reported in a previous work were not observed. The experimental results and cross-search of resonance energies in nuclear data libraries suggested that resonances of impurity nuclide $$^{141}$$Pr have been mistakenly assigned as $$^{142}$$Nd in the previous experiment. To investigate the impact of non-existence of the resonances to the s-process nucleosynthesis model, the Maxwellian averaged neutron capture cross sections with and without the misassigned resonances were compared.

論文

Response function for the measurement of (n,$$gamma$$) reactions with the ANNRI-Cluster Ge detectors at J-PARC

原 かおる; 後神 進史*; 原田 秀郎; 廣瀬 健太郎; 木村 敦; 金 政浩*; 北谷 文人; 小泉 光生; 中村 詔司; 藤 暢輔; et al.

JAEA-Conf 2014-002, p.88 - 92, 2015/02

Recently, neutron shields of a large Ge detector array at the Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) in the Japan Proton Accelerator Research Complex (J-PARC) were modified to suppress the background from boron rubber sheets to enriched $$^{6}$$LiF tiles. For the new experimental set-up, efficiencies and response functions of the cluster Ge detectors with the BGO anti-coincidence detectors were measured with $$gamma$$-rays from standard sources and prompt $$gamma$$-rays from the $$^{28}$$Si(n,$$gamma$$) and $$^{35}$$Cl(n,$$gamma$$) reactions. The simulation parameters were adjusted with the EGS5 code so as to reproduce the data set of efficiencies and response functions. Based on this information, a pulse height weighting function will be deduced in the energy range of 0.1-10 MeV.

論文

Analysis on effects of transverse electric field in an injector cavity of compact-ERL at KEK

Hwang, J.-G.*; Kim, E.-S.*; 宮島 司*; 本田 洋介*; 原田 健太郎*; 島田 美帆*; 高井 良太*; 久米 達哉*; 長橋 進也*; 帯名 崇*; et al.

Nuclear Instruments and Methods in Physics Research A, 753, p.97 - 104, 2014/07

 被引用回数:7 パーセンタイル:48.36(Instruments & Instrumentation)

For a future synchrotron light source based on a linac, e.g. an X-ray free electron laser and an energy recovery linac (ERL), an injector is a key component to generate a high brightness electron beam. For the acceleration and transportation of the electron beam in the injector, the adjustment of beam orbit inside the cavity is important to avoid the deterioration of the beam quality due to the transverse electric field of it, which causes the transverse emittance growth. To adjust the beam orbit, an investigation of the electromagnetic center of the cavity is required in the beam operation. This paper shows a new method for measuring the electromagnetic center of the cavity, and describes an analytical model of emittance growth due to a combination of transverse electric field and orbit offset. The validation of the method was confirmed by the emittance measurement in the compact ERL (cERL) injector at KEK.

論文

Measurements of neutron capture cross sections of $$^{112}$$Sn and $$^{118}$$Sn with J-PARC/MLF/ANNRI

木村 敦; 廣瀬 健太郎; 中村 詔司; 原田 秀郎; 原 かおる; 堀 順一*; 井頭 政之*; 加美山 隆*; 片渕 竜也*; 木野 幸一*; et al.

Nuclear Data Sheets, 119, p.150 - 153, 2014/05

 被引用回数:5 パーセンタイル:38.03(Physics, Nuclear)

The neutron-capture cross sections of $$^{112}$$Sn and $$^{118}$$Sn were measured by the time-of-flight method in the energy range from 10 meV to 2 keV with an array of germanium detectors in ANNRI at J-PARC. The preliminary results of the neutron-capture cross sections for $$^{112}$$Sn and $$^{118}$$Sn were obtained by normalizing the relative cross sections to the thermal cross section measured by Krane and to the evaluated value of JENDL-4.0 at the 47.05-eV resonance, respectively. Twelve new resonances for $$^{112}$$Sn were observed, whereas the 21.02-, 40.38- and 166-eV resonances for $$^{112}$$Sn and the 289-eV resonance for $$^{118}$$Sn which are listed on JENDL-4.0 and/or ENDF/B VII.1 were not observed. The prompt $$gamma$$-ray distributions gated at the $$^{112}$$Sn and $$^{118}$$Sn resonances were obtained. Twenty-three new prompt $$gamma$$-ray emissions were observed in the $$^{112}$$Sn (n,$$gamma$$) reactions.

論文

Cross section measurements of the radioactive $$^{107}$$Pd and stable $$^{105,108}$$Pd nuclei at J-PARC/MLF/ANNRI

中村 詔司; 木村 敦; 北谷 文人; 太田 雅之; 古高 和禎; 後神 進史*; 原 かおる; 原田 秀郎; 廣瀬 健太郎; 金 政浩*; et al.

Nuclear Data Sheets, 119, p.143 - 146, 2014/05

 被引用回数:10 パーセンタイル:57.34(Physics, Nuclear)

長寿命放射性核種$$^{107}$$Pd、及び不純物として含まれている安定核種$$^{105,108}$$Pdの中性子捕獲断面積を測定した。J-PARCの物質・生命科学実験施設(MLF)のBL04に整備された中性子核反応実験装置(ANNRI)を用いて、飛行時間法により熱領域から300eVの中性子エネルギーに対して、中性子捕獲断面積を測定した。報告されていた幾つかの共鳴が、$$^{107}$$Pdに起因しないことなど、共鳴に関する新たな知見が得られた。

論文

Capture cross-section measurement of $$^{241}$$Am(n,$$gamma$$) at J-PARC/MLF/ANNRI

原田 秀郎; 太田 雅之; 木村 敦; 古高 和禎; 廣瀬 健太郎; 原 かおる; 金 政浩*; 北谷 文人; 小泉 光生; 中村 詔司; et al.

Nuclear Data Sheets, 119, p.61 - 64, 2014/05

 被引用回数:19 パーセンタイル:76.05(Physics, Nuclear)

Accurate determination of the neutron capture cross sections of radioactive nuclei is required in the fields of nuclear waste transmutation study and also nuclear astrophysics. The accurate neutron-nucleus reaction measurement instrument (ANNRI), which was installed in the materials and life science experimental facility (MLF) at the J-PARC, is expected to satisfy these demands. The capture cross section of $$^{241}$$Am was measured using a high efficiency Ge spectrometer installed in the ANNRI. By taking advantage of its high $$gamma$$-ray energy resolution, background components were precisely subtracted. The capture cross section of $$^{241}$$Am was deduced for a neutron energy region between 0.01 and 20 eV. The obtained cross section and the Westcott factor are compared with the preceding experiments and evaluated values.

論文

Measurements of capture $$gamma$$ rays from the neutron resonances of $$^{74}$$Se and $$^{77}$$Se at the J-PARC/MLF/ANNRI

堀 順一*; 八島 浩*; 中村 詔司; 古高 和禎; 原 かおる; 原田 秀郎; 廣瀬 健太郎; 木村 敦; 北谷 文人; 小泉 光生; et al.

Nuclear Data Sheets, 119, p.128 - 131, 2014/05

 被引用回数:4 パーセンタイル:32.98(Physics, Nuclear)

本研究では、$$^{74}$$Seと$$^{77}$$Seの中性子共鳴からの捕獲$$gamma$$線を測定した。$$^{74}$$Seは、簡単な殻模型から2p$$_{1/2}$$軌道まで中性子が占有されている偶-偶核であるので、プライマリ$$gamma$$線遷移の始状態と終状態間の強い相関が予想される。$$^{74}$$Seは、安定Se同位体の中で唯一の奇数核であるので、同じ奇数核である$$^{79}$$Seの評価に資する情報を含んでいると期待される。J-PARC、物質・生命科学実験施設(MLF)の中性子核反応実験装置(ANNRI)に整備した4$$pi$$ Geスペクトロメータを用いて、飛行時間法により測定を行った。$$^{74}$$Seの27eV共鳴、及び$$^{77}$$Seの113eV, 212eV, 291eV, 342eV, 690eV及び864eV共鳴に対応する$$gamma$$線波高スペクトルを得た。これらのプライマリ遷移$$gamma$$線の相対強度を求め、報告されている実験データと比較を行った。$$^{74}$$Seの27eV共鳴について、293keV準位への強いプライマリ遷移が観測された。$$^{77}$$Seについては、共鳴ごとに全く異なる崩壊パターンを見いだした。

論文

Cross section measurement of $$^{237}$$Np$$(n,gamma)$$ at J-PARC/MLF/ANNRI

廣瀬 健太郎; 古高 和禎; 原 かおる; 原田 秀郎; 堀 順一*; 井頭 政之*; 加美山 隆*; 片渕 竜也*; 木村 敦; 金 政浩*; et al.

Nuclear Data Sheets, 119, p.48 - 51, 2014/05

 被引用回数:1 パーセンタイル:10.25(Physics, Nuclear)

The cross section of the $$^{237}$$Np$$(n,gamma)$$ reaction has been measured in an energy range from 10 meV to 1 keV at the Japan Proton Accelerator Research Complex (J-PARC). The NaI(Tl) spectrometer installed in the accurate neutron-nucleus reaction measurement instrument (ANNRI) was used for the measurement. The relative cross section was obtained using the neutron spectrum measured by the $$^{10}$$B$$(n,alpha_1)$$ reaction. The absolute value of the cross section was deduced by normalizing the relative cross section to the evaluated value in JENDL-4.0 at the first resonance. In this presentation, the obtained results for the cross section, the Westcott factor and the resonance analysis are reported. This work was supported by JSPS KAKENHI Grant Number 22226016.

論文

Energy resolution of pulsed neutron beam provided by the ANNRI beamline at the J-PARC/MLF

木野 幸一*; 古坂 道弘*; 平賀 富士夫*; 加美山 隆*; 鬼柳 善明*; 古高 和禎; 後神 進史*; 原 かおる; 原田 秀郎; 原田 正英; et al.

Nuclear Instruments and Methods in Physics Research A, 736, p.66 - 74, 2014/02

 被引用回数:31 パーセンタイル:91.8(Instruments & Instrumentation)

We studied the energy resolution of the pulsed neutron-beam of Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) at the Japan Proton Accelerator Research Complex/Materials and Life Science Experimental Facility (J-PARC/MLF). A simulation in the energy region from 0.7 meV to 1 MeV has been performed. Moreover, measurements have been done in the thermal and epithermal energies. The neutron energy resolution at ANNRI, which is determined by the time-of-flight technique, depends on the time structure of the neutron pulse. We obtained the neutron energy resolution as a function of the neutron energy by the simulation in the two operation modes of the neutron source: double and single bunch modes. In the double bunch mode, the resolution deteriorates above about 10 eV because the time structure of the neutron pulse splits into two peaks. The time structures at 13 energy points by measurements in the thermal energy region are in agreement with those of the simulation. In the epithermal energy region, the time structures at 17 energy points were obtained by measurements. The FWHM values of the time structures by the simulation and measurements are almost consistent. In the single bunch mode, the energy resolution is better than about 1% between 1 meV and 10 keV at the neutron source operation of 17.5 kW.

論文

Cross section measurement of $$^{117}$$Sn$$(n,gamma)$$ using ANNRI-NaI(Tl) spectrometer at J-PARC

廣瀬 健太郎; 古高 和禎; 原 かおる; 原田 秀郎; 木村 敦; 北谷 文人; 小泉 光生; 中村 詔司; 大島 真澄; 藤 暢輔; et al.

JAEA-Conf 2013-002, p.173 - 178, 2013/10

The cross section for $$^{117}$$Sn$$(n,gamma)$$ reaction has been measured in the neutron energy from 1eV to 1keV using the ANNRI-NaI(Tl) spectrometer at J-PARC/MLF. The sample used in the present experiment was metal tin enriched in $$^{117}$$Sn by 87%. The impurities of $$^{116}$$Sn and $$^{118}$$Sn were 9.3% and 3%, respectively. In the data analysis, the background of the frame-overlap neutrons and the scattered neutrons were subtracted. Comparison with the evaluation of JENDL-4.0 and ENDF/B-VII.1 will be presented in the poster session.

論文

Measurements and simulations of the responses of the cluster Ge detectors to $$gamma$$ rays

原 かおる; 後神 進史*; 原田 秀郎; 廣瀬 健太郎; 木村 敦; 金 政浩*; 北谷 文人; 小泉 光生; 中村 詔司; 藤 暢輔

JAEA-Conf 2013-002, p.161 - 166, 2013/10

For a pulse-height weighting technique, responses of two cluster Ge detectors with BGO anti-coincidence detectors have been measured at the Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) in the Japan Proton Accelerator Research Complex (J-PARC). $$^{60}$$Co and $$^{137}$$Cs standard sources were used for low-energy region (E$$_{gamma}$$ $$<$$ 2 MeV). Prompt $$gamma$$-rays emitted from the $$^{35}$$Cl(n,$$gamma$$)$$^{36}$$Cl reactions were used for high-energy region (E$$_{gamma}$$ $$sim$$ 8 MeV). The measured spectra, peak efficiencies, and peak-to-total ratio were compared to simulations which were calculated by using the EGS5 code in the energy range 0.5-10 MeV. The response function will be applied to a data analysis in neutron capture reaction measurements at ANNRI.

論文

Cross-section measurement of $$^{237}$$Np$$(n,gamma)$$ from 10 meV to 1 keV at Japan Proton Accelerator Research Complex

廣瀬 健太郎; 古高 和禎; 原 かおる; 原田 秀郎; 木村 敦; 金 政浩*; 北谷 文人; 小泉 光生; 中村 詔司; 大島 真澄; et al.

Journal of Nuclear Science and Technology, 50(2), p.188 - 200, 2013/02

 被引用回数:28 パーセンタイル:89.76(Nuclear Science & Technology)

J-PARC/ANNRIに設置したNaI検出器を用いて、$$^{237}$$Np$$(n,gamma)$$反応断面積を中性子エネルギー10meVから1keVにおいて測定した。断面積のエネルギー依存性は$$^{10}$$B$$(n,alpha)$$反応をリファレンスとして求め、絶対値はJENDL-4.0評価済データを用い、第1共鳴で規格化することで得た。得られた熱中性子捕獲断面積は(176.7$$pm$$4.7)bであった。また、$$kT$$=25.3meVに対するマクスウェル平均断面積は(174.6$$pm$$5.1)bであった。マクスウェル平均断面積を求める際、10meV以下での断面積はJENDL-4.0を参照した。これらの結果から、Westcottの$$g$$-factorとして0.988$$pm$$0.010が得られた。これは最新のLANLの測定値0.944$$pm$$0.035に比べ、約5%大きな結果である。

論文

Neutron capture cross section of palladium-107 in the thermal-neutron energy region

中村 詔司; 太田 雅之; 大島 真澄; 北谷 文人; 木村 敦; 金 政浩; 小泉 光生; 後神 進史*; 藤 暢輔; 原 かおる; et al.

JAEA-Conf 2012-001, p.147 - 152, 2012/07

The neutron capture cross section of $$^{107}$$Pd in the thermal-neutron energy region has been measured relative to the $$^{10}$$B(n,$$alphagamma$$) reaction cross section by the neutron time-of-flight (TOF) method. The relative cross section was normalized to the average value calculated by the SAMMY code with JENDL-4.0 at the three energy points: 6.8 eV of $$^{107}$$Pd, 11.8 eV of $$^{105}$$Pd, and 33 eV of $$^{108}$$Pd. Neutron-capture $$gamma$$ rays were measured with a large Ge detector array called "4$$pi$$Ge spectrometer", which is one component of the Accurate Neutron-Nucleus Reaction measurement Instrument (ANNRI) installed at the neutron Beam Line No.4 (BL04) of the Materials and Life science experimental Facility (MLF) in the Japan Proton Accelerator Research Complex (J-PARC). This paper presents new findings on resonance assignments of $$^{107}$$Pd, and the preliminary cross section.

論文

Neutron-capture cross-sections of $$^{244}$$Cm and $$^{246}$$Cm measured with an array of large germanium detectors in the ANNRI at J-PARC/MLF

木村 敦; 藤井 俊行*; 福谷 哲*; 古高 和禎; 後神 進史*; 原 かおる; 原田 秀郎; 廣瀬 健太郎; 堀 順一*; 井頭 政之*; et al.

Journal of Nuclear Science and Technology, 49(7-8), p.708 - 724, 2012/07

 被引用回数:51 パーセンタイル:96.43(Nuclear Science & Technology)

The neutron-capture cross sections of $$^{244}$$Cm and $$^{246}$$Cm were measured in the energy range of 1-300 eV with an array of large germanium detectors in the ANNRI at J-PARC/MLF. The resonances at around 7.7 and 16.8 eV of $$^{244}$$Cm and 4.3 and 15.3 eV of $$^{246}$$Cm were observed in capture reactions for the first time. The uncertainties of the obtained cross sections are 5.8% at the top of the first resonance of $$^{244}$$Cm and 6.6% at that of $$^{246}$$Cm. Resonance analyses were performed for low-energy ones using the code SAMMY. The prompt $$gamma$$-ray spectra of $$^{244}$$Cm and $$^{246}$$Cm were also obtained. Eight and five new prompt $$gamma$$-rays emitted were observed in the $$^{244}$$Cm(n,$$gamma$$) and $$^{246}$$Cm(n,$$gamma$$) reactions, respectively.

論文

The "Study on nuclear data by using a high intensity pulsed neutron source for advanced nuclear system" nuclear data project and the characteristics of the neutron beam line for the capture cross section experiments at J-PARC

鬼柳 善明*; 木野 幸一*; 古坂 道弘*; 平賀 富士夫*; 加美山 隆*; 加藤 幾芳*; 井頭 政之*; 片渕 竜也*; 水本 元治*; 大島 真澄; et al.

Journal of the Korean Physical Society, 59(2), p.1781 - 1784, 2011/08

 被引用回数:13 パーセンタイル:62.2(Physics, Multidisciplinary)

革新炉システムの開発に資するための包括的な核データ研究のプロジェクトが、2005年から2009年にわたり8つの機関により成功裏に実行された。このプロジェクトにおいて、長寿命核分裂生成物とマイナーアクチニドの中性子捕獲断面積を精密に得ることを目的として、パルス中性子ビームラインが建設された。ビームのエネルギースペクトル,空間分布,パルスが、測定とシミュレーション計算により調べられ、それらはビームラインの設計によるものと一致することがわかった。この論文でわれわれは、本プロジェクトの概要と本ビームラインにより供給される中性子ビームの特性を述べる。

論文

Recent progress in the energy recovery linac project in Japan

坂中 章悟*; 明本 光生*; 青戸 智浩*; 荒川 大*; 浅岡 聖二*; 榎本 収志*; 福田 茂樹*; 古川 和朗*; 古屋 貴章*; 芳賀 開一*; et al.

Proceedings of 1st International Particle Accelerator Conference (IPAC '10) (Internet), p.2338 - 2340, 2010/05

日本においてERL型放射光源を共同研究チームで提案している。電子銃,超伝導加速空洞などの要素技術開発を進めている。また、ERL技術の実証のためのコンパクトERLの建設も進めている。これら日本におけるERL技術開発の現状について報告する。

論文

Progress in R&D efforts on the energy recovery linac in Japan

坂中 章悟*; 吾郷 智紀*; 榎本 収志*; 福田 茂樹*; 古川 和朗*; 古屋 貴章*; 芳賀 開一*; 原田 健太郎*; 平松 成範*; 本田 融*; et al.

Proceedings of 11th European Particle Accelerator Conference (EPAC '08) (CD-ROM), p.205 - 207, 2008/06

コヒーレントX線,フェムト秒X線の発生が可能な次世代放射光源としてエネルギー回収型リニアック(ERL)が提案されており、その実現に向けた要素技術の研究開発が日本国内の複数研究機関の協力のもと進められている。本稿では、ERL放射光源の研究開発の現状を報告する。

論文

An Intense terahertz radiation source at the Compact ERL

原田 健太郎*; 島田 美帆*; 羽島 良一

Infrared Physics & Technology, 51(5), p.386 - 389, 2008/05

 被引用回数:4 パーセンタイル:25.11(Instruments & Instrumentation)

原子力機構,高エネルギー加速器研究機構,東京大学が共同で建設を進めているコンパクトERLでは、フェムト秒の電子パルスを大電流で加速できる。このフェムト秒電子パルスから発生されるコヒーレント放射光は、テラヘルツの波長領域で極めて高い強度を有する。コンパクトERLの電子ビームパラメータに基づいて、テラヘルツ光源の特性を評価する。

論文

コンパクトERL電子ビーム光学系の設計研究

白神 剛志*; 中村 典雄*; 原田 健太郎*; 島田 美穂*; 坂中 章悟*; 小林 幸則*; 羽島 良一

Proceedings of 5th Annual Meeting of Particle Accelerator Society of Japan and 33rd Linear Accelerator Meeting in Japan (CD-ROM), p.589 - 591, 2008/00

エネルギー回収型リニアック放射光源のための実証機である「コンパクトERL」について、周回軌道の電子ビーム光学系の設計を行った。周回軌道中においてバンチ圧縮を行う構成では、77pCのバンチ電荷に対して、40フェムト秒の超短電子パルスが生成できることを示した。

39 件中 1件目~20件目を表示