検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 42 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Hybridization of Bogoliubov quasiparticles between adjacent CuO$$_2$$ layers in the triple-layer cuprate Bi$$_2$$Sr$$_2$$Ca$$_2$$Cu$$_3$$O$$_{10+delta}$$ studied by angle-resolved photoemission spectroscopy

出田 真一郎*; Johnston, S.*; 吉田 鉄平*; 田中 清尚*; 森 道康; 安齋 太陽*; 井野 明洋*; 有田 将司*; 生天目 博文*; 谷口 雅樹*; et al.

Physical Review Letters, 127(21), p.217004_1 - 217004_6, 2021/11

 被引用回数:6 パーセンタイル:49.47(Physics, Multidisciplinary)

Hybridization of Bogoliubov quasiparticles (BQPs) between the CuO$$_2$$ layers in the triple-layer cuprate high-temperature superconductor Bi$$_2$$Sr$$_2$$Ca$$_2$$Cu$$_3$$O$$_{10+delta}$$ is studied by angle-resolved photoemission spectroscopy (ARPES). In the superconducting state, an anti-crossing gap opens between the outer- and inner-BQP bands, which we attribute primarily to interlayer single-particle hopping with possible contributions from interlayer Cooper pairing. We find that the $$d$$-wave superconducting gap of both BQP bands smoothly develops with momentum without abrupt jump in contrast to a previous ARPES study. Hybridization between the BQPs also gradually increases in going from the off-nodal to the anti-nodal region, which is explained by the momentum-dependence of the interlayer single-particle hopping. As possible mechanisms for the enhancement of the superconducting transition temperature, the hybridization between the BQPs, as well as the combination of phonon modes of the triple CuO$$_2$$ layers and spin fluctuations are discussed.

論文

The Possible interplanetary transfer of microbes; Assessing the viability of ${it Deinococcus}$ spp. under the ISS environmental conditions for performing exposure experiments of microbes in the Tanpopo mission

河口 優子*; Yang, Y.*; 川尻 成俊*; 白石 啓祐*; 高須 昌子*; 鳴海 一成*; 佐藤 勝也; 橋本 博文*; 中川 和道*; 谷川 能章*; et al.

Origins of Life and Evolution of Biospheres, 43(4-5), p.411 - 428, 2013/10

 被引用回数:41 パーセンタイル:80.34(Biology)

In the Tanpopo mission, we have proposed to carry out experiments on capture and space exposure of microbes at the Exposure Facility of the Japanese Experimental Module of the International Space Station (ISS). Microbial candidates for the exposure experiments in space include ${it Deinococcus}$ spp. We have examined the survivability of ${it Deinococcus}$ spp. under the environmental conditions in ISS in orbit. A One-year dose of heavy-ion beam irradiation did not affect the viability of ${it Deinococcus}$ spp. within the detection limit. Exposure of various thicknesses of deinococcal cell aggregates to UV radiation revealed that a few hundred micrometer thick aggregate of deinococcal cells would be able to withstand the solar UV radiation on ISS for 1 year. We concluded that aggregated deinococcal cells will survive the yearlong exposure experiments. We propose that microbial cells can aggregate as an ark for the interplanetary transfer of microbes, and we named it "massapanspermia".

論文

Three-dimensional and multienergy $$gamma$$-ray simultaneous imaging by using a Si/CdTe Compton camera

鈴木 義行*; 山口 充孝; 小高 裕和*; 島田 博文*; 吉田 由香里*; 鳥飼 幸太*; 佐藤 隆博; 荒川 和夫*; 河地 有木; 渡辺 茂樹; et al.

Radiology, 267(3), p.941 - 947, 2013/06

 被引用回数:23 パーセンタイル:65.03(Radiology, Nuclear Medicine & Medical Imaging)

Capabillity tests of 3D imaging for medical applications were performed by using a new Compton camera. $$^{18}$$F, $$^{131}$$I and $$^{67}$$Ga separately compacted into micro tubes were injected subcutaneously into a Wister rat and imaged after sacrifice of the rat (ex-vivo model). In a separate experiment $$^{111}$$In-chloride and $$^{131}$$I-Methylnorcholestenol were injected into a rat intravenously and $$^{64}$$Cu was injected into the stomach orally just before imaging (more physiological model). The Compton camera demonstrated its 3D multinuclear imaging capability by separating out the three nuclear distributions clearly in ex-vivo model. In the more physiological model, the distributions of $$^{131}$$I and $$^{64}$$Cu were clearly imaged although $$^{111}$$In was difficult to visualize due to blurring at low energy region of $$gamma$$-ray. In conclusion, our new Compton camera successfully demonstrated highly resolved multiplanar and multinuclear $$gamma$$-ray simultaneous imaging.

論文

Three-dimensional imaging test for a head module of a Si/CdTe Compton camera for medical application

山口 充孝; 河地 有木; 神谷 富裕; 佐藤 隆博; 鈴井 伸郎; 藤巻 秀; 小高 裕和*; 石川 真之介*; 国分 紀秀*; 渡辺 伸*; et al.

JAEA-Review 2011-043, JAEA Takasaki Annual Report 2010, P. 145, 2012/01

現在、三次元撮像が可能な医学用コンプトンカメラとしてマルチヘッドコンプトンカメラシステムの開発を行っている。今回、システムの構成要素であるヘッドモジュールプロトタイプ機の製作を行い、Ba133点線源を用い性能試験を行った。測定結果は線源の位置を正確に反映し、点線源の撮像が問題なく可能であることを確認できた。測定データから見積もった装置の空間分解能は、シミュレーションスタディで得られている結果とよく一致した。装置近傍領域においては、検出器面に対して垂直方向の分解能も有することが、実験結果及びシミュレーション結果の両面から実証された。

論文

Development of head module for multi-head Si/CdTe Compton camera for medical applications

山口 充孝; 河地 有木; 鈴井 伸郎; 藤巻 秀; 神谷 富裕; 小高 裕和*; 石川 真之介*; 国分 紀秀*; 渡辺 伸*; 高橋 忠幸*; et al.

Nuclear Instruments and Methods in Physics Research A, 648(Suppl.1), p.S2 - S7, 2011/08

 被引用回数:2 パーセンタイル:19.86(Instruments & Instrumentation)

現在Si/CdTeコンプトンカメラを用いた、3次元撮像が可能な医学・生物学用のイメージングシステムの構築を進めている。このシステムは、数十keVから数MeVの広いエネルギー範囲において、高いエネルギー分解能及び空間分解能を有し、複数核種同時イメージングが可能であるという特徴を有する。これまでにカメラの近接領域においては、単一のカメラヘッドのみで、奥行き方向の情報を取得可能であることを、シミュレーションスタディを通して示してきたが、今回、実際に実機を用いて測定を行い、奥行き方向も含めた3次元情報が一台のヘッドのみで取得可能であることを確認した。また、得られた位置分解能が、シミュレーションスタディの結果とよく一致していることも確認できた。

論文

Counting rate performance measurement of newly developed Si/CdTe Compton camera for biological and medical applications

山口 充孝; 河地 有木; 神谷 富裕; 鈴井 伸郎; 藤巻 秀; 小高 裕和*; 石川 真之介*; 国分 紀秀*; 渡辺 伸*; 高橋 忠幸*; et al.

2010 IEEE Nuclear Science Symposium Conference Record (CD-ROM), p.2004 - 2007, 2010/10

In recent developed radionuclide-based imaging technologies utilized for biological and medical studies, wide dynamic range of radiation intensity with a good quantitative linearity is one of the most important factors. However, the linearity of a detector or a sensor generally breaks due to the dead-time increasing in high counting rate. Therefore, in case of an imaging camera, which is a large set of detectors, it is essential to measure the sensitivity profile of it varying with the radiation source intensity for correction of nonlinearity of each detector. Si/CdTe Compton camera is comprised of two layered double-sided Si strip detectors and two layered double-sided CdTe strip detectors with a four-layer laminated structure. For imaging, the source positions of $$gamma$$-rays are identified by analysing the deposited energies and the scattering angles from counted events in those of detectors. In this work, the Compton camera that was newly developed for biological and medical applications was investigated on the counting rate performance, and the sensitivity profile of this highly complicated imaging system was measured using a $$^{18}$$F point $$gamma$$-ray source. The intense source of 20 MBq was used to measure the sensitivity profiles for a wide range of counting rate in a short period. The result was compared with a calculation using a model considering the dead time of the detection system.

報告書

核融合原型炉SlimCSの概念設計

飛田 健次; 西尾 敏*; 榎枝 幹男; 中村 博文; 林 巧; 朝倉 伸幸; 宇藤 裕康; 谷川 博康; 西谷 健夫; 礒野 高明; et al.

JAEA-Research 2010-019, 194 Pages, 2010/08

JAEA-Research-2010-019-01.pdf:48.47MB
JAEA-Research-2010-019-02.pdf:19.4MB

発電実証だけでなく、最終的には経済性までを一段階で見通しうる核融合原型炉SlimCSの概念設計の成果を報告する。核融合の開発では、これまで、1990年に提案されたSSTR(Steady State Tokamak Reactor)が標準的な原型炉概念とされてきたが、本研究はSSTRより軽量化を図るため小規模な中心ソレノイドを採用して炉全体の小型化と低アスペクト比化を図り、高ベータ及び高楕円度(グリーンワルド密度限界を高めうる)を持つ炉心プラズマにより高出力密度を目指した。主要パラメータは、プラズマ主半径5.5m,アスペクト比2.6,楕円度2.0,規格化ベータ値4.3,核融合出力2.95GW,平均中性子壁負荷3MW/m$$^{2}$$とした。この炉概念の技術的成立性を、プラズマ物理,炉構造,ブランケット,超伝導コイル,保守及び建屋の観点から検討した。

論文

Recent progress in the energy recovery linac project in Japan

坂中 章悟*; 明本 光生*; 青戸 智浩*; 荒川 大*; 浅岡 聖二*; 榎本 収志*; 福田 茂樹*; 古川 和朗*; 古屋 貴章*; 芳賀 開一*; et al.

Proceedings of 1st International Particle Accelerator Conference (IPAC '10) (Internet), p.2338 - 2340, 2010/05

日本においてERL型放射光源を共同研究チームで提案している。電子銃,超伝導加速空洞などの要素技術開発を進めている。また、ERL技術の実証のためのコンパクトERLの建設も進めている。これら日本におけるERL技術開発の現状について報告する。

論文

Compact DEMO, SlimCS; Design progress and issues

飛田 健次; 西尾 敏; 榎枝 幹男; 川島 寿人; 栗田 源一; 谷川 博康; 中村 博文; 本多 充; 斎藤 愛*; 佐藤 聡; et al.

Nuclear Fusion, 49(7), p.075029_1 - 075029_10, 2009/07

 被引用回数:137 パーセンタイル:97.72(Physics, Fluids & Plasmas)

最近の核融合原型炉SlimCSに関する設計研究では、おもに、ブランケット,ダイバータ,材料,保守を含む炉構造の検討に重点を置いている。この設計研究における炉構造の基本的考え方とそれに関連する課題を報告する。楕円度のついたプラズマの安定化と高ベータ化のため、セクター大の導体シェルを交換ブランケットと固定ブランケット間に設置する構造とした。また、ブランケットには、加圧水冷却,固体増殖材を採用することとした。従来の原型炉設計で検討していた超臨界水冷却を利用するブランケット概念に比べ、トリチウム自給を満足するブランケット概念の選択肢はかなり絞られる。ダイバータ技術やその材料について考慮すると、原型炉のダイバータ板での熱流束上限は8MW/m$$^{2}$$以下とすべきであり、これは原型炉で取り扱うパワー(すなわち、アルファ加熱パワーと電流駆動パワーの和)に対して大きな制約となりうる。

論文

Basic characteristics of a newly developed Si/CdTe Compton camera for medical imaging

河地 有木; 渡邉 茂樹; 佐藤 隆博; 荒川 和夫; 武田 伸一郎*; 石川 真之介*; 青野 博之*; 渡辺 伸*; 山口 充孝*; 高橋 忠幸*; et al.

2008 IEEE Nuclear Science Symposium Conference Record (CD-ROM), p.1540 - 1543, 2008/10

The Compton camera is a very promising medical imaging system when we consider multiple radionuclide imaging and its sensitivity, portability and compactness. We have developed a Compton camera by using Si and CdTe semiconductors for medical imaging. The prototype Compton camera head consists of a double-sided Si strip detector (DSSD) module as the scatter detector and four layered 16 CdTe pixel detector modules as the absorber detector. The DSSD has an area of 2.56$$times$$2.56 cm, a thickness of 500 $$mu$$m and a strip pitch of 400 $$mu$$m. The CdTe pixel detector has an area of 1.35$$times$$1.35 cm, a thickness of 500 $$mu$$m and a pixel size of 1.35 mm$$^{2}$$. The high-energy resolution detectors (DSSD: $$Delta$$E/E$$sim$$2.5%, CdTe: $$Delta$$E/E$$sim$$1%) enable detect the Compton scatter events of the incident $$gamma$$-rays, in consequence image radioactive multi-nuclide tracer. We evaluated distributions of sensitivity and spatial resolution, and rat study was performed with three tracers ($$^{111}$$In, $$^{131}$$I, $$^{64}$$Cu) concurrently-administered. As results, lines of point-source data indicated 4 mm spatial resolution in the center of field of view (FOV) in this experimental design, and a characteristic manner of the distributions in the Compton camera FOV was shown. The nuclides in the rat body were distinguished by the $$gamma$$-ray energies, each tracer imaged separately in vivo, and the difference in distribution among the nuclide was visualized successfully.

論文

Design and operation of high-energy and high-average-power diode-pumped single Nd:YAG amplifier with stimulated-Brillouion-scattering phase conjugate mirror

桐山 博光; 山川 考一; 影山 進人*; 宮島 博文*; 菅 博文*; 吉田 英次*; 中塚 正大*

Japanese Journal of Applied Physics, Part 1, 44(10), p.7464 - 7471, 2005/10

 被引用回数:2 パーセンタイル:9.29(Physics, Applied)

高平均出力・高繰り返しチタンサファイアレーザーの小型化,高効率化を目的として半導体レーザー(LD)励起Nd:YAGレーザーMOPA(Master-Oscillator-Power-Amplifier)システムの開発を行った。本システムは、低い入力エネルギーで高いエネルギー抽出効率を達成するため、レーザービームが励起領域を6回通過できる多重パス増幅方式を採用している。高ビーム品質の増幅を行うためにジグザグスラブ型増幅器で、さらにファラデーローテーター及びSBS位相共役鏡を用いて、それぞれ熱複屈折効果と熱レンズ効果を保証できる構成としている。また、高い変換効率で第二高調波光を発生させるために、非線形光学定数の大きいKTP結晶を採用した。本システムの動作試験を1kHzの高繰り返しで行った。平均のLD入力パワー2.6kWにおいて362Wの高平均出力(1064-nm)を達成した。$$sim$$1500の増幅度並びに14%の光-光変換効率を得た。また、波長変換試験において222Wの入力パワーに対して132Wの高平均第二高調波出力光(532-nm)が60%の高い変換効率で得られた。

論文

360-W average power operation with a single-stage diode-pumped Nd:YAG amplifier at a 1-kHz repetition rate

桐山 博光; 山川 考一; 永井 亨; 影山 進人*; 宮島 博文*; 菅 博文*; 吉田 英次*; 中塚 正大*

Optics Letters, 28(18), p.1671 - 1673, 2003/09

 被引用回数:29 パーセンタイル:74.02(Optics)

高平均出力・高繰り返しチタンサファイアレーザーの小型化,高効率化を目的として半導体レーザー(LD)励起Nd:YAGレーザーMOPA(Master-Oscillator-Power-Amplifier)システムの開発を行った。本システムは、低い入力エネルギーで高いエネルギー抽出効率を達成するため、レーザービームが励起領域を6回通過できる多重パス増幅方式を採用している。高ビーム品質の増幅を行うためにジグザグスラブ型増幅器で、さらにファラデーローテーター及びSBS位相共役鏡を用いて、それぞれ熱複屈折効果と熱レンズ効果を補償できる構成としている。また、高い変換効率で第二高調波光を発生させるために、非線形光学定数の大きいKTP結晶を採用した。本システムの動作試験を1kHzの高繰り返し率で行った。平均のLD入力パワー2.6kWにおいて362Wの高平均出力(1064-nm)を達成した。$$sim$$1500の増幅度並びに14%の光-光変換効率を得た。また、波長変換試験において222Wの入力パワーに対して132Wの高平均第二高調波出力光(532-nm)が60%の高い変換効率で得られた。

報告書

ITER用トリチウム貯蔵ベッドからのトリチウム透過量評価

中村 博文; 林 巧; 鈴木 卓美; 吉田 浩*; 西 正孝

JAERI-Research 2000-044, 24 Pages, 2000/10

JAERI-Research-2000-044.pdf:0.97MB

通気式熱量計測型トリチウム貯蔵ベッドからのトリチウム透過を、国際熱核融合炉(ITER)で現在提案されている運転モードについて計算・評価した。評価の結果、合理化に伴って新たに提案されている運転モードでは、最もトリチウム透過が大きいと考えられる条件下での評価において従来の運転方法に比べ、積算透過率が約2倍となるとの結果を得た。しかし、透過するトリチウム量としてはITERでの計量管理制度の範囲内であることを確認した。一方、トリチウムの安全管理や通気式計量ベッドの性能維持の観点からは、熱量測定と真空断熱性能維持のために、適切なトリチウムの処理が必要であることが示唆された。さらに、構成材料をステンレス鋼から銅に変えることにより、透過量低減が図られる可能性が示唆された。

論文

Multilaser and high spatially resolved multipoint Thomson scattering system for the JT-60U tokamak

吉田 英俊; 内藤 磨; 山下 修; 北村 繁; 佐久間 猛*; 小野瀬 義秋*; 根本 博文*; 浜野 隆*; 波多江 仰紀; 長島 章; et al.

Review of Scientific Instruments, 70(1), p.751 - 754, 1999/01

 被引用回数:15 パーセンタイル:68.26(Instruments & Instrumentation)

JT-60Uトムソン散乱測定装置の最新の設計と測定実績について総合報告する。本装置は超高温な電子温度や高精度な電子密度の過渡変化を、定量的であるがゆえに精密なアラインメントの常時監視下で高信頼測定が可能であるという特長を有する。2台のルビーレーザから発せられるビームを光学的に同質かつ同一直線上に伝搬させる、施光子とファラデー回転子から成るビーム合成装置を開発して、2ミリ秒の時間差での過渡事象現象測定を可能にした。プラズマ炉心部から周辺部まで約2mにわたって60空間点のトムソン散乱光を8~22mmの高分解能で2台の集光器で集光する。低電子密度プラズマを小立体角かつ高空間分解能で高精度に測定するため超高感度の光電子増倍管を採用し、また高温高密度の炉心プラズマを対象に高繰返し計測が可能な2次元型検出器を開発・導入した。講演では、最新の測定結果についても言及する。

報告書

Fabrication of beryllium spheres and its validation tests

吉田 浩; 榎枝 幹男; 中村 博文; 成瀬 雄二

JAERI-M 92-116, 108 Pages, 1992/08

JAERI-M-92-116.pdf:17.51MB

ベリリウム微小球を用いたsphere-pack型ブランケットは、中性子照射損傷、ヘリウムスエリング、熱サイクルによるベリリウムの変形(膨張、割れ)を緩和できる期待から、INTOR設計以来の日本のブランケット概念の中心となっている。本概念では直径0.5~6mmのベリリウム球が用いられ、特にプラズマに近い領域では0.5~1mmの球が必要とされる。ITERのCDA段階において、1$$pm$$0.3mmを当面の目標とした微小球の試作開発に着手し、サイズ分布の調節の可能性を検討するとともに製造されたベリリウム球の特性解析、核融合運転条件を想定した熱サイクル耐久性試験を行なった。本報告書は1989年~1991年の期間に実施したこれらのR&Dの結果をまとめたものである。

報告書

Nb基およびMo基耐熱合金の材料設計と評価

森永 正彦*; 斉藤 淳一*; 加藤 真人*; 一色 泰志*; 脇山 博文*; 加納 茂機; 吉田 英一

PNC TY9623 92-001, 73 Pages, 1992/04

PNC-TY9623-92-001.pdf:6.17MB

Li冷却高速炉用の構造材料として、これまでの研究でNb基およびMo基合金を候補材料として選択し、その材料設計および特性評価を行ってきた。これらの合金の中から候補材の成分を更に絞るため、本年度は3元系合金について引張強度の簡易的予測手法、密度の予測手法の検討および2元系および3元系合金についてナトリウムに対する耐食性評価手法の検討を行った。3元系のNb基合金およびMo基合金をトリアーク炉で溶製し、高温硬さ試験、923K、1000hのナトリウム中腐食試験、密度測定、組織観察を行った。さらにNb基2元系合金についてナトリウム中腐食試験を行い、腐食に対する合金効果を検討した。(1)前年度導出した2元系合金に関する引張強度の簡易的予測手法(成分元素間の原子半径差およびヤング率差に基づく)が3元系合金に拡張できることを明らかにした。(2)密度の予測が合金元素の密度の組成平均で予測できることを明らかにした。(3)ナトリウムに対する腐食に関し、合金効果を明らかにし、耐食性を予測するため新たに耐食性係数を導出した。この他に1373KにおけるMo-Re-W系の部分状態図を作成した。上記の結果をもとに、最も有望な候補合金系としてNb-W-V-Zr系合金およびMo-Re-W-Zr系合金を選択した。

口頭

医用Si/CdTeコンプトンカメラ試作機による複数元素同時撮イメージング

河地 有木; 渡邉 茂樹; 佐藤 隆博; 松橋 信平; 荒川 和夫; 武田 伸一郎*; 石川 真之介*; 青野 博文*; 渡辺 伸*; 高橋 忠幸*; et al.

no journal, , 

生体内のさまざまな元素動態を同時に非侵襲的かつ定量的にイメージングする手法は、生命科学に新たな知見を与えることができる。競合する複数分子の同一個体内生理反応システムを多次元的に可視化する、粒子線治療時に照射部位から発生する微量な即発$$gamma$$線などを多角的かつ効率的にモニタリングする、などさまざまな応用研究が期待できる。原子力機構・宇宙航空研究開発機構・群馬大学では、この複数元素同時イメージングを目的とし、高エネルギー分解能を持つ半導体検出器を用いたコンプトンカメラの開発を行っている。今回の試作機は400$$mu$$mピッチのDouble-sided Si Strip Detector(DSSD)と4層の1.35mm$$^{2}$$のピクセルサイズを持つCdTe Detectorに低ノイズアナログASICを組合せて構築した、Si/CdTeコンプトンカメラである。この試作機を用いて、ファントム撮像によるコンプトンカメラ基礎特性評価データを取得し、エネルギーの異なる3核種(511keV: $$^{64}$$Cu, 364keV: $$^{131}$$I, 254keV: $$^{111}$$In)を用いたイメージング実験を行った。その結果、生体内複数核種トレーサの同時イメージングに成功し、またコンプトンカメラの特性である独特な感度分布及び分解能分布、120度以上という広視野角が明確になった。これは装置・RI・画像解析といった実験条件の最適化を容易にし、今後予定している次世代医用コンプトンカメラの開発に向けた基本設計に非常に有用な基礎データである。

口頭

Multi-tracer Compton imaging by a newly developed Si/CdTe Compton camera

河地 有木; 渡邉 茂樹; 藤巻 秀; 石岡 典子; 荒川 和夫; 武田 伸一郎*; 石川 真之介*; 青野 博之*; 渡辺 伸*; 高橋 忠幸*; et al.

no journal, , 

We have developed a Compton camera by using Si and CdTe semiconductors. The prototype Compton camera head consists of a double-sided Si strip detector (DSSD) module as the scatter detector and 4- layered 16 CdTe pixel detector modules as the absorber detector. The dimensions of the DSSD module are area, 2.56 $$times$$ 2.56 cm$$^{2}$$; thickness, 500 $$mu$$m; and strip pitch, 400 $$mu$$m. The dimensions of the CdTe pixel detector are area, 1.35 $$times$$ 1.35 cm$$^{2}$$; thickness, 500 $$mu$$m; and pixel size, 1.35 mm. The high-energy resolution detectors (DSSD: $$Delta$$E/E, 2.5%; CdTe: $$Delta$$E/E, $$sim$$1%) detect the Compton scatter events of the incident $$gamma$$-rays and consequently, image the radioactive multinuclide tracers. We evaluated the distributions of sensitivity and spatial resolution and performed a rat study wherein 3 tracers were administered concurrently. The lines of point-source data were found to indicate a distribution of spatial resolutions and efficiencies in the field of view (FOV) in this experimental design, and a characteristic distribution in the Compton camera FOV was observed. The nuclides in the rat body were distinguished by the $$gamma$$-ray energies; each tracer in vivo could be imaged distinctly, and the difference in distributions of the nuclides could be visualized.

口頭

Performance characterization of a prototype Si/CdTe Compton camera

河地 有木; 渡邉 茂樹; 藤巻 秀; 石岡 典子; 佐藤 隆博; 神谷 富裕; 荒川 和夫; 渡辺 伸*; 武田 伸一郎*; 石川 真之介*; et al.

no journal, , 

The Compton camera is a next-generation in vivo imaging system. In order to achieve accurate Compton imaging, it is necessary to develop technologies that can be used to detect the Compton scattering in the camera and estimate the direction of a incoming $$gamma$$-ray produced by a radiation source. These techniques will be different from the methods used in PET and SPECT to detect the $$gamma$$-ray with the coincidence of two points and with the physical collimation. We have developed a prototype Compton camera for in vivo imaging by using semiconductor imaging devices, which has been proved to be successful techniques for the an observation of high-energy astrophysical phenomena. In this camera, double-sided Si strip detectors (DSSDs) serve as scatterers and CdTe pixel detectors serve as absorbers. In this paper, we present some images acquired with the Compton camera; we have also acquired images of radioisotopes in a phantom, which reveal certain characteristic distributions of efficiencies and spatial resolutions.

口頭

Development of Si/CdTe Compton camera for medical imaging

山口 充孝*; 荒川 和夫; 青野 博之*; 石川 真之介*; 神谷 富裕; 河地 有木; 小高 裕和*; 櫻井 英幸*; 佐藤 隆博; 島田 博文*; et al.

no journal, , 

We have developed a prototype of Compton camera using Si/CdTe semiconductors for medical imaging. In a Compton camera, employing the imaging semiconductors as the component of the Compton camera, with their good energy and position resolution, improves angular resolution and hence sensitivity. Moreover, for the supposed energy range of $$gamma$$ rays, from several tens keV to a few MeV, silicon is suitable for the scatter of Compton camera since the photo absorption cross section of Si is small and the Compton cross-section is relatively large because of the small atomic number. On the other hand, CdTe is suitable for the absorbers because of its high photo-absorption efficiency for $$gamma$$ rays of this energy region, due to the large atomic numbers. In this presentation we will summarize the basic principle and performance of the Si/CdTe Compton camera for medical imaging.

42 件中 1件目~20件目を表示