Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Bersweiler, M.*; 佐藤 宏和*; 足立 望*; 戸高 義一*; Peral, I.*; Kohlbrecher, J.*; Zaporozhets, V. D.*; Metlov, K. L.*; Michels, A.*; 大場 洋次郎
IUCrJ, 10(4), p.411 - 419, 2023/07
被引用回数:2 パーセンタイル:43.78(Chemistry, Multidisciplinary)Magnetic microstructures in severely deformed iron produced via high-pressure torsion (HPT) straining have been investigated using small-angle neutron scattering. The results reveal that nonneglibible third-order scattering contribution in the inhomogeneities amplitude of magnetization is induced via HPT straining and the contribution becomes small with subsequent annealing. The contribution has negative values, which suggest that the inhomogeneity of the magnetic anisotropy enhanced via HPT is a possible origin of the third-order contribution.
和田 有希*; 榎戸 輝揚*; 中澤 知洋*; 湯浅 孝行*; 古田 禄大; 小高 裕和*; 牧島 一夫*; 土屋 晴文
Journal of Geophysical Research; Atmospheres, 125(20), p.e2020JD033194_1 - e2020JD033194_15, 2020/10
被引用回数:4 パーセンタイル:10.92(Meteorology & Atmospheric Sciences)During a winter thunderstorm on 6th February 2017 in Japan, photonuclear reactions such as N(
)
N were triggered by a downward terrestrial gamma-ray flash (TGF), as reported by Enoto et al. (2017). In the present paper, we compare the observation with a simulation model of downward TGFs and subsequent photonuclear reactions constructed by the first paper of the series and Wada, Enoto, Nakazawa, et al. (2019). The observation and model consist of three components: annihilation gamma rays from positrons produced by
-decay nuclei, de-excitation gamma rays originating from neutron captures, and radiation doses by TGF photons. Each component of the observation is reproduced by the simulation model, and we constrain a relation between the number of avalanche electrons and their production altitude of the downward TGF. The constrains by three components match within an order of magnitude. The downward TGF is estimated to comprise
10
avalanche electrons above 1 MeV produced at an altitude of 1.4-2.7 km. Despite differences in altitude, direction, and season, downward TGFs in winter thunderstorms are thought to have the same mechanism of electron acceleration and multiplication in lightning as TGFs observed by in-orbit satellites.
和田 有希*; 榎戸 輝揚*; 中澤 知洋*; 小高 裕和*; 古田 禄大; 土屋 晴文
Journal of Geophysical Research; Atmospheres, 125(20), p.e2020JD033193_1 - e2020JD033193_17, 2020/10
被引用回数:5 パーセンタイル:15.21(Meteorology & Atmospheric Sciences)We report simulation results of photonuclear reactions in the atmosphere triggered by a downward terrestrial gamma-ray flash in lightning. Possible channels of reactions in the atmosphere and their cross sections are verified with the ENDF/B-VII.1 library. Monte-Carlo simulations with two stages are then performed with the Geant4 framework. In the first stage, electrons following the relativistic runaway electron avalanche spectrum are produced in a mass model of the atmosphere, and production of photoneutrons and -decay nuclei is calculated based on the nuclear data library. In total 1
neutrons and 4
-decay nuclei are produced by
energetic electrons above 1 MeV. In the second stage, propagation of the photoneutrons and positrons from the
-decay nuclei in the previous stage is calculated. As a result, we model on-ground distributions of fluxes and energy spectra for neutrons, neutron-related gamma rays, and annihilation ones. The simulation model is to be compared with photonuclear events detected in low-charge-center winter thunderstorms.
鈴木 義行*; 山口 充孝; 小高 裕和*; 島田 博文*; 吉田 由香里*; 鳥飼 幸太*; 佐藤 隆博; 荒川 和夫*; 河地 有木; 渡辺 茂樹; et al.
Radiology, 267(3), p.941 - 947, 2013/06
被引用回数:24 パーセンタイル:64.15(Radiology, Nuclear Medicine & Medical Imaging)Capabillity tests of 3D imaging for medical applications were performed by using a new Compton camera. F,
I and
Ga separately compacted into micro tubes were injected subcutaneously into a Wister rat and imaged after sacrifice of the rat (ex-vivo model). In a separate experiment
In-chloride and
I-Methylnorcholestenol were injected into a rat intravenously and
Cu was injected into the stomach orally just before imaging (more physiological model). The Compton camera demonstrated its 3D multinuclear imaging capability by separating out the three nuclear distributions clearly in ex-vivo model. In the more physiological model, the distributions of
I and
Cu were clearly imaged although
In was difficult to visualize due to blurring at low energy region of
-ray. In conclusion, our new Compton camera successfully demonstrated highly resolved multiplanar and multinuclear
-ray simultaneous imaging.
山口 充孝; 長尾 悠人; 河地 有木; 藤巻 秀; 神谷 富裕; 小高 裕和*; 国分 紀秀*; 武田 伸一郎*; 渡辺 伸*; 高橋 忠幸*; et al.
Proceedings of 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 3 Pages, 2013/00
A Monte Carlo simulation system was developed to estimate the response of Compton camera against -ray emissions from RI spots in a PET-standard human-body phantom. The quality of the three-dimensional imaging program for the Si/CdTe Compton camera to reconstruct the image of the RI spots in a phantom was evaluated by the system, when the phantom has three hot sphere-regions with the same known RI density and different diameters, in other words, different known intensities. The density values of the hot regions reconstructed by the three-dimensional imaging program for the Compton camera were consistent to the known intensities of the RI. It demonstrates sufficient quality of the program for Si/CdTe Compton camera to image RI spots in the phantom.
小高 裕和*; 一戸 悠人*; 武田 伸一郎*; 福山 太郎*; 萩野 浩一*; 齋藤 新也*; 佐藤 有*; 佐藤 悟朗*; 渡辺 伸*; 国分 紀秀*; et al.
Nuclear Instruments and Methods in Physics Research A, 695, p.179 - 183, 2012/12
被引用回数:24 パーセンタイル:82.23(Instruments & Instrumentation)Si/CdTe半導体両面ストリップ検出器(DSD)を用いた新しいコンプトンカメラの開発を行った。このカメラは、各面において電極が128ストリップ(250mピッチ)で分割されている、厚さ500
mのSi-DSDと4層の厚さ750
mのCdTe-DSDから成り、ファインピッチのDSDを4mm間隔で積層配置することで、高角度分解能(356keVで4.5度、662keVで3.5度)を有しかつ小型な装置を実現している。許容できる検出効率を保ちつつこのような高解像度を得るために、コンプトン散乱連続スペクトルを用いたエネルギー較正法と、CdTe-DSD内の深度計測を用いたデータ処理法を新たに試みた。さらに、同時マルチエネルギーイメージングの結果を用いて、カメラの撮像能力について詳細な検討を行った。
武田 伸一郎*; 一戸 悠人*; 萩野 浩一*; 小高 裕和*; 湯浅 孝行*; 石川 真之介*; 福山 太郎*; 齋藤 新也*; 佐藤 有*; 佐藤 悟朗*; et al.
Physics Procedia, 37, p.859 - 866, 2012/10
被引用回数:25 パーセンタイル:98.53(Physics, Applied)ASTRO-Hミッションのために開発されたSi/CdTe半導体両面ストリップ検出器(DSD)を利用したコンプトンカメラを用い、放射線ホットスポットのモニタリングの実行可能性チェックを目的とした複数放射線源の画像化実験を行った。本装置は半導体検出器によって与えられた良好なエネルギー分解能により、既に商業的な画像処理システムが提供するホットスポットの画像可能力に加え、複数の放射性同位元素を同定する能力を有する。今回の実験では、Ba(356keV),
Na(511keV)及び
Cs(662keV)の三放射性同位元素を同時に測定し、これらの画像化に成功した。5つの検出器モジュール(有効面積: 1.7
10
cm
)を積み重ねることによって、662keVの
線に対し、検出効率1.68
10
、及び、3.8度の角度分解能を確認した。本装置は、より多くの検出器モジュールをスタックすることにより、さらに大きな検出効率を達成することが可能である。
山口 充孝; 河地 有木; 神谷 富裕; 佐藤 隆博; 鈴井 伸郎; 藤巻 秀; 小高 裕和*; 石川 真之介*; 国分 紀秀*; 渡辺 伸*; et al.
JAEA-Review 2011-043, JAEA Takasaki Annual Report 2010, P. 145, 2012/01
現在、三次元撮像が可能な医学用コンプトンカメラとしてマルチヘッドコンプトンカメラシステムの開発を行っている。今回、システムの構成要素であるヘッドモジュールプロトタイプ機の製作を行い、Ba133点線源を用い性能試験を行った。測定結果は線源の位置を正確に反映し、点線源の撮像が問題なく可能であることを確認できた。測定データから見積もった装置の空間分解能は、シミュレーションスタディで得られている結果とよく一致した。装置近傍領域においては、検出器面に対して垂直方向の分解能も有することが、実験結果及びシミュレーション結果の両面から実証された。
山口 充孝; 河地 有木; 鈴井 伸郎; 藤巻 秀; 神谷 富裕; 小高 裕和*; 石川 真之介*; 国分 紀秀*; 渡辺 伸*; 高橋 忠幸*; et al.
Nuclear Instruments and Methods in Physics Research A, 648(Suppl.1), p.S2 - S7, 2011/08
被引用回数:2 パーセンタイル:19.35(Instruments & Instrumentation)現在Si/CdTeコンプトンカメラを用いた、3次元撮像が可能な医学・生物学用のイメージングシステムの構築を進めている。このシステムは、数十keVから数MeVの広いエネルギー範囲において、高いエネルギー分解能及び空間分解能を有し、複数核種同時イメージングが可能であるという特徴を有する。これまでにカメラの近接領域においては、単一のカメラヘッドのみで、奥行き方向の情報を取得可能であることを、シミュレーションスタディを通して示してきたが、今回、実際に実機を用いて測定を行い、奥行き方向も含めた3次元情報が一台のヘッドのみで取得可能であることを確認した。また、得られた位置分解能が、シミュレーションスタディの結果とよく一致していることも確認できた。
山口 充孝; 河地 有木; 神谷 富裕; 鈴井 伸郎; 藤巻 秀; 小高 裕和*; 石川 真之介*; 国分 紀秀*; 渡辺 伸*; 高橋 忠幸*; et al.
2010 IEEE Nuclear Science Symposium Conference Record (CD-ROM), p.2004 - 2007, 2010/10
In recent developed radionuclide-based imaging technologies utilized for biological and medical studies, wide dynamic range of radiation intensity with a good quantitative linearity is one of the most important factors. However, the linearity of a detector or a sensor generally breaks due to the dead-time increasing in high counting rate. Therefore, in case of an imaging camera, which is a large set of detectors, it is essential to measure the sensitivity profile of it varying with the radiation source intensity for correction of nonlinearity of each detector. Si/CdTe Compton camera is comprised of two layered double-sided Si strip detectors and two layered double-sided CdTe strip detectors with a four-layer laminated structure. For imaging, the source positions of -rays are identified by analysing the deposited energies and the scattering angles from counted events in those of detectors. In this work, the Compton camera that was newly developed for biological and medical applications was investigated on the counting rate performance, and the sensitivity profile of this highly complicated imaging system was measured using a
F point
-ray source. The intense source of 20 MBq was used to measure the sensitivity profiles for a wide range of counting rate in a short period. The result was compared with a calculation using a model considering the dead time of the detection system.
武田 伸一郎*; 青野 博之*; 奥山 翔*; 石川 真之介*; 小高 裕和*; 渡辺 伸*; 国分 紀秀*; 高橋 忠幸*; 中澤 知洋*; 田島 宏康*; et al.
IEEE Transactions on Nuclear Science, 56(3), p.783 - 790, 2009/06
被引用回数:57 パーセンタイル:95.72(Engineering, Electrical & Electronic)A semiconductor Compton camera that combines silicon (Si) and Cadmium Telluride (CdTe) detectors was developed, and its imaging capability was examined with various kinds of -ray targets such as a point source, arranged point sources and an extended source. The camera consists of one double-sided Si strip detector and four layers of CdTe pad detectors, and was designed to minimize the distance between a scatterer and the target. This is because the spatial resolution with Compton imaging improves as the target approaches the scatterer. This new camera realizes a minimum distance of 25 mm. By placing the target at a distance of 30 mm from the detector, resolving power better than 3 mm was demonstrated experimentally for a 364 keV (
I)
-ray. Positional determination with accuracy of 1 mm was also demonstrated. As a deconvolution method, we selected the iteration algorithm (called List-Mode Expectation-Maximizing Maximum Likelihood), and applied it to several kinds of experimental data. The Compton back projection images of the arranged point sources and an extended object were successfully deconvolved.
山口 充孝*; 河地 有木; 渡辺 伸*; 小高 裕和*; 武田 伸一郎*; 石川 真之介*; 青野 博之*; 高橋 忠幸*; 荒川 和夫; 中野 隆史*
2008 IEEE Nuclear Science Symposium Conference Record (CD-ROM), p.4000 - 4002, 2008/10
We have developed a prototype of Compton camera using Si/CdTe semiconductors for medical imaging. In the case where the detection area of Compton camera is restricted to small region, position resolution of depth direction is expected to be low. To overcome this weakness, we propose multi-head Compton camera. In this work, we evaluated the position resolutions of single- and double-head Compton camera by using Monte Carlo simulation. After the Monte Carlo simulation, two hit Compton event was selected, and back-projection and image reconstruction were performed in 3D-space. Consequently, the position resolution of the z-axis was about 5.6 mm for double-head camera whereas about 27 mm for single-head camera. These results indicate that the position resolution is improved and clear 3D-image is taken by using multi-head Compton camera.
武田 伸一郎*; 青野 博之*; 石川 真之介*; 小高 裕和*; 渡辺 伸*; 国分 紀秀*; 高橋 忠幸*; 奥山 翔*; 中澤 知洋*; 田島 宏康*; et al.
no journal, ,
A -ray imaging detector is required in various fields such as high-energy astrophysics, medical imaging and nondestructive inspection. We have proposed a concept of the Si/CdTe semiconductor Compton camera, which consists of many layers of thin Si and CdTe detectors. The Si/CdTe Compton camera features high energy resolution and high angular resolution. Recently, we developed a new Compton camera system for a balloon borne astrophysical experiment. It consists of a 4-layers stack of double-sided silicon strip detector (DSSD) modules and 32 CdTe pad detectors symmetrically surrounding the DSSD stack. The Compton reconstruction was successfully performed and the
-ray images were obtained from 662 keV down to 59.5 keV. The Angular Resolution Measure (ARM) is 3.5 degree (FWHM) and 2.5 degree (FWHM) at 356 keV and 511 keV, respectively. The Si/CdTe Compton camera which has such good angular resolution is also attractive for medical imaging and/or nondestructive inspection. An internal structure of about one mm can be resolved when the distance between the camera and a target becomes closer than a few mm. We developed another prototype which enable us to approach the target down to 20 mm. In this presentation, we will show the experimental results of this prototype and also discuss Compton reconstruction methods.
青野 博之*; 武田 伸一郎*; 石川 真之介*; 小高 裕和*; 国分 紀秀*; 渡辺 伸*; 高橋 忠幸*; 中澤 知洋*; 奥山 翔*; 田島 宏康*; et al.
no journal, ,
We have developed a low noise double-sided silicon strip detector for hard X-ray imaging spectroscopy. Development of low-noise analog electronics, optimized double-sided silicon strip detectors and a compact assembly technology realized the high-quality X-ray imaging device with fine energy, position and timing resolutions, and good uniformity. Imaging detectors in 10-100 keV would be attractive in various fields such as astrophysics, medical and nondestructive inspection. For these purposes, the development the next generation Compton Camera is now underway.
山口 充孝; 神谷 富裕; 河地 有木; 鈴井 伸郎; 藤巻 秀; 石岡 典子; 渡辺 伸*; 石川 真之介*; 小高 裕和*; 国分 紀秀*; et al.
no journal, ,
医学イメージング用途のSi/CdTeコンプトンカメラのプロトタイプの開発を行ってきた。コンプトンカメラヘッドが単一である場合、深度方向の空間分解能は低く3次元的に解像度の良い撮像は不可能である。分解能の改善のため、われわれは複数ヘッド型コンプトンカメラを提案してきた。今回、コンプトンカメラを用いた実験データとモンテカルロシミュレーション結果とを比較し、単一ヘッド装置の空間分解能を検証した。さらに、マルチヘッド化の影響調査のため、ダブルヘッド装置のシミュレーションによる分解能評価を行った。カメラヘッドは2枚のSiストリップ検出器と2枚のCdTeストリップ検出器からなる。モンテカルロシミュレーションにはGEANT4を用いたカメラシミュレーターを用いた。イメージングには、LM-ML-EM法を用いた。測定結果はシミュレーションによる結果とよく一致した。深度方向の空間分解能は、単一ヘッドの場合、おおよそ15mmであるが、ダブルヘッドの場合6mm程度に改善されることがシミュレーションにより示唆された。これらの結果はマルチヘッド化による3次元空間分解能の改善を示唆するものである。
山口 充孝; 神谷 富裕; 河地 有木; 鈴井 伸郎; 藤巻 秀; 小高 裕和*; 石川 真之介*; 国分 紀秀*; 渡辺 伸*; 高橋 忠幸*; et al.
no journal, ,
3次元撮像が可能な医学用コンプトンカメラとして、現在、マルチヘッドコンプトンカメラシステムの開発を行っている。今回、システムの構成要素であるヘッドモジュールのプロトタイプ機の製作を行い、Ba-133密封線源を用いて性能試験を行った。測定結果は、線源の位置を正確に反映し、点線源の撮像が問題なく可能であることを確認できた。測定データから見積もった装置の角度分解能は4.5度であり、シミュレーションスタディで得られている結果とよく一致した。今回のモジュールは、マルチヘッドを実現するためヘッドサイズは直径22cm高さ24cm程度にまで小型化を実現した。モジュールはロボットアームに設置し、患部への接近配置が可能となるよう設計している。今回製作したモジュールをマルチヘッド化した場合の3次元空間分解能の向上についてシミュレーションスタディにより評価を行った。本会議ではこれらの結果について報告を行う。
山口 充孝; 神谷 富裕; 河地 有木; 鈴井 伸郎; 石岡 典子; 藤巻 秀; 渡辺 伸*; 石川 真之介*; 小高 裕和*; 国分 紀秀*; et al.
no journal, ,
われわれは宇宙航空研究開発機構宇宙科学研究所が中心となって開発したコンプトンカメラ技術を転用し、高い空間分解能とエネルギー分解能を併せ持ち、幅広いエネルギー領域の線源を撮像できる医学・生物学用三次元イメージングシステムの構築を進めている。このシステムは、位置敏感型半導体検出器と低ノイズAnalog ASIC回路を使用することで、コンプトンカメラとして優れた分解能を実現し、散乱体にシリコン(Si)、吸収体にカドミウム(CdTe)を採用することで高い検出効率を実現している。さらに、コンパクトにモジュール化したコンプトンカメラを一つのヘッドとし、複数ヘッドによる多方面からの撮像を可能にすることで、三次元的に高い空間分解能を有したイメージングシステムとしている。これまでにヘッドモジュール一台の製作が完了し、密封線源(Ba-133)を用いた性能評価試験を行った。試験結果をモンテカルロシミュレーションと比較した結果、両者がよく一致することが確認できた。本発表では、製作したモジュールの詳細と、性能評価の結果と、シミュレーションによる複数ヘッド化の効果について報告する。
山口 充孝; 長尾 悠人; 河地 有木; 藤巻 秀; 荒川 和夫*; 神谷 富裕; 小高 裕和*; 国分 紀秀*; 武田 伸一郎*; 渡辺 伸*; et al.
no journal, ,
医学分野における近距離領域撮像用のコンプトンカメラは、散乱体を起点とした角度分解能ではなく、検出体最表面を起点とした角度分解能(実効角度分解能)を指標として検出器構成の設計を行う必要がある。また、検査・治療支援等を目的とした撮像を行う際は、撮像時間の短縮及び投与RIの減量によって、患者の身体的及び精神的負担を軽減するため、コンプトンカメラの設計には検出効率向上に重きを置く必要が生じる。そこで、CdTeが散乱体かつ吸収体となるイベント(CdTe-CdTeイベント)を取り入れることによる検出効率の大幅な向上効果と、その際の実効角度分解能を指標として検出器構成のシミュレーションによる検討を行った。これに基づいて構築したSi1枚CdTe4枚の構成を持つコンプトンカメラについて、Ba-133(356keV)の点線源を用いて検出効率と角度分解能を測定した結果はシミュレーション結果と整合した。これにより、Si/CdTeコンプトンカメラによる近接領域撮像においてCdTe-CdTeイベントを取り入れることによる検出効率の向上効果の有効性が実証できた。
酒井 真理*; 菊地 美貴子*; 鳥飼 幸太*; 荒川 和夫*; 山口 充孝; 長尾 悠人; 河地 有木; 藤巻 秀; 神谷 富裕; 小高 裕和*; et al.
no journal, ,
コンプトンカメラは多核種同時撮像能力を持つことから、新しい核医学診断装置として期待されている。我々は臨床研究を目指し、体内に集積した放射性薬剤の可視可能性について基礎データの収集を行っている。本発表では宇宙線観測用に開発されたSi/CdTeコンプトンカメラを基本としたシステムおよびNEMA IECボディファントムを用いて、人体体幹部による
線散乱の影響について評価を行った。ファントム中心部にNa-22, Co-57, Ba-133の標準点線源を設置し、それらからの511keV, 122keV, 356keVの
線について、ファントム内が空気の状態と、人体を模すために水を満たした状態でそれぞれ撮像を行い比較した。その結果、取得画像での位置分解能の変化はほとんど見られなかったが、画質の顕著な低下が見られた。コンプトンカメラで取得された
線エネルギースペクトルを比較したところ、水での
線散乱の影響によって画像再構成に用いることのできたイベント数がおよそ1/2に減少しており、かつエネルギー幅の広がりや低エネルギー側のバックグランドレベルの増加が生じており、このことが原因と考えられた。今後画像再構成手法の見直しにより画質改善を図るとともに、複数核種同時撮影時の核種定量に向けてさらに検討を進める予定である。
長尾 悠人; 山口 充孝; 河地 有木; 藤巻 秀; 神谷 富裕; 武田 伸一郎*; 小高 裕和*; 渡辺 伸*; 国分 紀秀*; 高橋 忠幸*; et al.
no journal, ,
従来のガンマカメラ・SPECTといった線イメージング装置は、物理的コリメータを実装しているために感度と空間分解能の向上が競合してしまうという本質的な問題を抱えており、また対象となる
線も低エネルギーに限られている。これに対しコンプトンカメラは、コンプトン散乱の運動学を
線のコリメーションに応用することで、感度と空間分解能の向上が競合せず、また幅広いエネルギーの
線を撮像可能な次世代
線イメージング装置である。照射施設管理課は、宇宙観測用に開発が進められているSi/CdTe半導体コンプトンカメラを、医学・生物学における生体内トレーサイメージングへ応用することを目的とした研究開発を行っている。特に、医学・生物学での利用には、カメラの近接領域に存在するRIトレーサの分布を定量的に推定することが不可欠である。本研究では、そのために必要な画像再構成手法の改良を行った。