Refine your search:     
Report No.
 - 
Search Results: Records 1-12 displayed on this page of 12
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Bithiophene with winding vine-shaped molecular asymmetry; Preparation, structural characterization, and enantioselective synthesis

Toyomori, Yuka*; Tsuji, Satoru*; Mitsuda, Shinobu*; Okayama, Yoichi*; Ashida, Shiomi*; Mori, Atsunori*; Kobayashi, Toru; Miyazaki, Yuji; Yaita, Tsuyoshi; Arae, Sachie*; et al.

Bulletin of the Chemical Society of Japan, 89(12), p.1480 - 1486, 2016/09

 Times Cited Count:8 Percentile:29.47(Chemistry, Multidisciplinary)

Journal Articles

High-resolution Compton cameras based on Si/CdTe double-sided strip detectors

Odaka, Hirokazu*; Ichinohe, Yuto*; Takeda, Shinichiro*; Fukuyama, Taro*; Hagino, Koichi*; Saito, Shinya*; Sato, Tamotsu*; Sato, Goro*; Watanabe, Shin*; Kokubun, Motohide*; et al.

Nuclear Instruments and Methods in Physics Research A, 695, p.179 - 183, 2012/12

 Times Cited Count:23 Percentile:84.01(Instruments & Instrumentation)

We have developed a new Si/CdTe semiconductor double-sided strip detector (DSD) Compton camera. The camera consists of a 500-$$mu$$m-thick Si-DSD and four layers of 750-$$mu$$m-thick CdTe-DSDs all of which have common electrode configuration segmented into 128 strips on each side with pitches of 250$$mu$$m. In order to realize high angular resolution and to reduce size of the detector system, a stack of DSDs with short stack pitches of 4 mm is utilized to make the camera. Taking advantage of the excellent energy and position resolutions of the semiconductor devices, the camera achieves high angular resolutions of 4.5 degrees at 356 keV and 3.5 degrees at 662 keV. To obtain such high resolutions together with an acceptable detection efficiency, we demonstrate data reduction methods including energy calibration using Compton scattering continuum and depth sensing in the CdTe-DSD. We also discuss imaging capability of the camera and show simultaneous multi-energy imaging.

Journal Articles

Applications and imaging techniques of a Si/CdTe Compton $$gamma$$-ray camera

Takeda, Shinichiro*; Ichinohe, Yuto*; Hagino, Koichi*; Odaka, Hirokazu*; Yuasa, Takayuki*; Ishikawa, Shinnosuke*; Fukuyama, Taro*; Saito, Shinya*; Sato, Tamotsu*; Sato, Goro*; et al.

Physics Procedia, 37, p.859 - 866, 2012/10

 Times Cited Count:22 Percentile:98.43(Physics, Applied)

By using new Compton camera consisting of silicon double-sided strip detector (Si-DSD) and CdTe-DSD developed for the ASTRO-H mission, an experiment was conducted to study its feasibility for advanced hotspot monitoring. In addition to hotspot imaging already provided by commercial imaging systems, the identification of the variety of radioisotopes is realized thanks to the good energy resolution given by the semiconductor detectors. Three radioisotopes of $$^{133}$$Ba (356 keV), $$^{22}$$Na (511 keV) and $$^{137}$$Cs (662 keV) were individually imaged by applying event selection in the energy window and the $$gamma$$-ray images was correctly overlapped by an optical picture. The detection efficiency of 1.68$$times$$10$$^{-4}$$ (effective area: 1.7$$times$$10$$^{-4}$$ cm$$^2$$) and angular resolution of 3.8$$^{circ}$$ were obtained by stacking five detector modules for 662 keV $$gamma$$-ray. The higher detection efficiency required in a specific use can be achieved by stacking more detector modules.

Journal Articles

Inter-atomic force constants of Ag$$_{2}$$O from diffuse neutron scattering measurement

Wada, Tamotsu*; Sakuma, Takashi*; Sakai, Ryutaro*; Uehara, Hiroyuki*; Xianglian*; Takahashi, Haruyuki*; Kamishima, Osamu*; Igawa, Naoki; Danilkin, S. A.*

Solid State Ionics, 225, p.18 - 21, 2012/10

 Times Cited Count:12 Percentile:44.07(Chemistry, Physical)

Diffuse neutron scattering measurement on Ag$$_{2}$$O crystals was performed at 8 K and 295 K. The observed diffuse scattering intensities were analyzed by including the correlation effects among thermal displacements of atoms in Ag$$_{2}$$O. Using the values of correlation effects among neighboring atoms and the values of Debye-Waller temperature parameter, force constants among first, second and third nearest neighboring atoms have been evaluated.

Journal Articles

Electrical characteristics of interface defects in oxides grown at 1200 $$^{circ}$$C in dry oxygen ambient on silicon carbide and their thermal annealing effects

Yoshikawa, Masahito; Ishida, Yuki*; Jikimoto, Tamotsu*; Hijikata, Yasuto*; Ito, Hisayoshi; Okumura, Hajime*; Takahashi, Tetsuo*; Tsuchida, Hidekazu*; Yoshida, Sadafumi*

Denshi Joho Tsushin Gakkai Rombunshi, C, 86(4), p.426 - 433, 2003/04

no abstracts in English

Journal Articles

The Investigation of 4H-SiC/SiO$$_{2}$$ interfaces by optical and electrical measurements

Ishida, Yuki*; Takahashi, Tetsuo*; Okumura, Hajime*; Jikimoto, Tamotsu*; Tsuchida, Hidekazu*; Yoshikawa, Masahito; Tomioka, Yuichi*; Midorikawa, Masahiko*; Hijikata, Yasuto*; Yoshida, Sadafumi*

Materials Science Forum, 389-393, p.1013 - 1016, 2002/00

 Times Cited Count:4 Percentile:20.33(Materials Science, Multidisciplinary)

no abstracts in English

Journal Articles

Activities of Nuclear Emergency Assistance & Training Center (NEAT)

Ishida, Junichiro; Takahashi, Keizo; Nomura, Tamotsu

The First Asian and Oceanic Congress for Radiation Protection (AOCRP-1), 0 Pages, 2002/00

None

JAEA Reports

Questionnaire on the measurement condition of distribution coefficient

Takebe, Shinichi; Kimura, Hideo; Matsuzuru, Hideo; Takahashi, Tomoyuki*; Yasuda, Hiroshi*; Uchida, Shigeo*; Mahara, Yasunori*; Saeki, Akiyoshi*; Sasaki, Noriyuki*; Ashikawa, Nobuo*; et al.

JAERI-Review 2001-015, 81 Pages, 2001/05

JAERI-Review-2001-015.pdf:5.94MB

no abstracts in English

JAEA Reports

An Irradiation test of heat-resistant ceramic composite materials; Interim report on post-irradiation examinations of the first preliminary irradiation test 97M-13A

Baba, Shinichi; Suzuki, Yoshio*; Takahashi, Tsuneo*; Ishihara, Masahiro; Hayashi, Kimio; Saito, Tamotsu; Sozawa, Shizuo; Saito, Takashi; Sekino, Hajime

JAERI-Research 2001-028, 109 Pages, 2001/03

JAERI-Research-2001-028.pdf:4.55MB

no abstracts in English

Journal Articles

Intercomparison of measurements and questionnaire on the distribution coefficient

Takahashi, Tomoyuki*; Takebe, Shinichi; Kimura, Hideo; Matsuzuru, Hideo; Yasuda, Hiroshi*; Uchida, Shigeo*; Saeki, Akiyoshi*; Mahara, Yasunori*; Sasaki, Noriyuki*; Ashikawa, Nobuo*; et al.

KURRI-KR-44, p.169 - 176, 2000/02

no abstracts in English

JAEA Reports

Intercomparison on measurement of distribution coefficient; Investigation on differences of measured values between individuals

Takahashi, Tomoyuki; Takebe, Shinichi; Kimura, Hideo; Matsuzuru, Hideo; Yasuda, Hiroshi*; Uchida, Shigeo*; Saeki, Akiyoshi*; Mahara, Yasunori*; Sasaki, Noriyuki*; *; et al.

JAERI-Research 97-089, 25 Pages, 1997/12

JAERI-Research-97-089.pdf:1.11MB

no abstracts in English

Oral presentation

Diffuse neutron scattering measurements of Ag$$_{2}$$O and Cu$$_{2}$$O

Sakai, Ryutaro*; Wada, Tamotsu*; Sakuma, Takashi*; Takahashi, Haruyuki*; Kamishima, Osamu*; Igawa, Naoki; Danilkin, S. A.*

no journal, , 

The correlation effects among thermal displacements of atoms in Ag$$_{2}$$O and Cu$$_{2}$$O are studied at 8 and 295 K by diffuse neutron scattering method. The force constants of these substances are obtained from the correlation effects and Debye-Waller temperature parameters. The mean square of the thermal displacements of atoms can be obtained in terms of correlation effects and Debye-Waller temperature parameters. The inter-atomic force constants among first and second nearest neighboring atoms have been estimated at room temperature. The calculated force constants in the present works were almost equal to that of ionic crystals.

12 (Records 1-12 displayed on this page)
  • 1