Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Okuno, Hiroshi; Yamamoto, Kazuya
JAEA-Review 2020-066, 32 Pages, 2021/02
The International Atomic Energy Agency (abbreviated as IAEA) has been implementing the Asian Nuclear Safety Network (abbreviated as ANSN) activities since 2002. As part of this effort, Topical Group on Emergency Preparedness and Response (abbreviated as EPRTG) for nuclear or radiation disasters was established in 2006 under the umbrella of the ANSN. Based on the EPRTG proposal, the IAEA conducted 23 Asian regional workshops in the 12 years from 2006 to 2017. Typical topical fields of the regional workshops were nuclear emergency drills, emergency medical care, long-term response after nuclear/radiological emergency, international cooperation, national nuclear disaster prevention system. The Japan Atomic Energy Agency has produced coordinators for EPRTG since its establishment and has led its activities since then. This report summarizes the Asian regional workshops conducted by the IAEA based on the recommendations of the EPRTG.
Kumada, Hiroaki; Yamamoto, Kazuyoshi; Torii, Yoshiya; Matsumura, Akira*; Yamamoto, Tetsuya*; Nose, Tadao*; Nakagawa, Yoshinobu*; Kageji, Teruyoshi*; Uchiyama, Junzo
JAERI-Tech 2003-002, 49 Pages, 2003/03
no abstracts in English
Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Endo, Kiyoshi*; Yamamoto, Tetsuya*; Matsumura, Akira*; Uchiyama, Junzo; Nose, Tadao*
JAERI-Tech 2002-092, 23 Pages, 2002/12
Thermal neutron flux is determined using the gold wires in current BNCT irradiation, so evaluation of arbitrary points after the irradiation is limited in the quantity of these detectors. In order to make up for the weakness, dose estimation of a patient is simulated by a computational dose calculation supporting system. In another way without computer simulation, a medical irradiation condition can be replicate experimentally using of realistic phantom which was produced from CT images by rapid prototyping technique. This phantom was irradiated at a same JRR-4 neutron beam as clinical irradiation condition of the patient and the thermal neutron distribution on the brain surface was measured in detail. This experimental evaluation technique using a realistic phantom is applicable to in vitro cell irradiation experiments for radiation biological effects as well as in-phantom experiments for dosimetry under the nearly medical irradiation condition of patient.
Endo, Kiyoshi*; Matsumura, Akira*; Yamamoto, Tetsuya*; Nose, Tadao*; Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Kashimura, Takanori*; Otake, Shinichi*
Research and Development in Neutron Capture Therapy, p.425 - 430, 2002/09
Using the Rapid Prototyping Technique, we produced a realistic phantom as a formative model of a patient head. This realistic phantom will contribute to verification of our planning system. However, cross-correlation among the calculations using the JAERI Computational Dosimetry System (JCDS), the realistic phantom, and the in vivo measurements were not fully completed because of the difficulty involved in modeling a post-surgical brain and a thermal neutron shield. The experimental simulation technique using the realistic phantom is a useful tool for more reliable dose planning for the intraoperative BNCT.
Kumada, Hiroaki; Matsumura, Akira*; Nakagawa, Yoshinobu*; Yamamoto, Tetsuya*; Yamamoto, Kazuyoshi; Torii, Yoshiya
Research and Development in Neutron Capture Therapy, p.529 - 534, 2002/09
no abstracts in English
Nose, Tadao*; Matsumura, Akira*; Yamamoto, Tetsuya*; Shibata, Yasushi*; Yoshida, Fumiyo*; Akutsu, Hiroyoshi*; Yasuda, Susumu*; Matsushita, Akira*; Nakai, Kei*; Yamada, Takashi*; et al.
UTRCN-G-29, p.114 - 123, 2001/00
no abstracts in English
; ;
JAERI-M 9146, 72 Pages, 1980/10
no abstracts in English