検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 169 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Oxidation and embrittlement behavior of FeCrAl-ODS cladding tube under loss-of-coolant accident conditions

成川 隆文; 近藤 啓悦; 藤村 由希; 垣内 一雄; 宇田川 豊; 根本 義之

Journal of Nuclear Materials, 587, p.154736_1 - 154736_8, 2023/12

 被引用回数:1 パーセンタイル:63.33(Materials Science, Multidisciplinary)

To evaluate the oxidation and embrittlement behavior of an oxide-dispersion-strengthened FeCrAl (FeCrAl-ODS) cladding tube under loss-of-coolant accident (LOCA) conditions, we conducted isothermal oxidation and ring-compression tests on unirradiated, stress-relieved FeCrAl-ODS cladding tube specimens. Further, we discussed the loss of coolable geometry of the reactor core loaded with the FeCrAl-ODS cladding tubes under LOCA conditions, using data from the ring-compression tests in this study and the integral thermal shock tests from our previous study. The results reveal that oxidation kinetics of the FeCrAl-ODS cladding tube at 1523 K is four orders of magnitude lower than that of a conventional Zircaloy cladding tube, which highlights the exceptional oxidation resistance of the FeCrAl-ODS cladding tube. The breakaway oxidation of the FeCrAl-ODS cladding tube was observed at 1623 K for durations equal to or exceeding 6 h, and melting was observed at 1723 K. The ring-compression and the integral thermal shock tests indicate that, depending on the oxidation time, the ductile to brittle transition threshold - as determined by the ring-compression test - exists between 1623 K and 1723 K. Meanwhile, the fracture threshold - established through the integral thermal shock test - falls between 1573 K and 1673 K. Therefore, taking a conservative approach based on available data, the fracture and non-fracture results from the integral thermal shock tests can define the lower and upper boundaries of the threshold for the loss of coolable geometry of the reactor core during a LOCA.

論文

Microstructural evolution of intermetallic phase precipitates in Cr-coated zirconium alloy cladding in high-temperature steam oxidation up to 1400$$^{circ}$$C

Mohamad, A. B.; 根本 義之; 古本 健一郎*; 岡田 裕史*; 佐藤 大樹*

Corrosion Science, 224, p.111540_1 - 111540_15, 2023/11

 被引用回数:0 パーセンタイル:0.00(Materials Science, Multidisciplinary)

The steam oxidation test on the Cr-coated Zry cladding was studied up to 1400$$^{circ}$$C to understand the oxidation behavior under the accidental conditions. The double-sided oxidation test study showed that Cr coating can protect Zry cladding at 1200$$^{circ}$$C within 5 min. Cr coating has a protective effect on the Zry cladding up to 1200$$^{circ}$$C in a steam environment. However, in the oxidation test up to 1200$$^{circ}$$C/30 min and 1300$$^{circ}$$C/5 min, Cr coating can no longer protect Zry cladding. Furthermore, at 1300$$^{circ}$$C, the intermetallic phase of the Zr(Cr, Fe)$$_{2}$$ phase that precipitated within the Zry substrate formed as globule microstructures with Fe enrichment. In addition, the transition of the intermetallic phase within the Zry substrate from the solid to the pre-liquid and liquid phases was observed, where it was determined at 1350$$^{circ}$$C/60 min and 1400$$^{circ}$$C/30 min within the ZrO$$_{2}$$ phase (outer side region). The oxidation of the Zr(Cr, Fe)$$_{2}$$ interlayer was also determined in this study, where it resulted in the formation of the oxide phase of Cr, Zr, and Fe. It is worth mentioning that further experiments, such as mechanical testing and modeling, should be considered to support the degradation of the Cr-coated Zry cladding mainly when the liquid phase of the intermetallic phase is obtained for beyond design-basis accident environment.

論文

Behavior of FeCrAl-ODS cladding tube under loss-of-coolant accident conditions

成川 隆文; 近藤 啓悦; 藤村 由希; 垣内 一雄; 宇田川 豊; 根本 義之

Journal of Nuclear Materials, 582, p.154467_1 - 154467_12, 2023/08

 被引用回数:3 パーセンタイル:92.52(Materials Science, Multidisciplinary)

To evaluate the behavior of an oxide-dispersion-strengthened FeCrAl (FeCrAl-ODS) cladding tube under loss-of-coolant accident (LOCA) conditions of light-water reactors (LWRs), the following two laboratory-scale LOCA-simulated tests were performed: the burst and integral thermal shock tests. Four burst and three integral thermal shock tests were performed on unirradiated, stress-relieved FeCrAl-ODS cladding tube specimens, simulating ballooning and rupture, oxidation, and quenching, which were postulated during a LOCA. The burst temperature of the FeCrAl-ODS cladding tube was 200-300 K higher than that of the Zircaloy cladding tube, and the FeCrAl-ODS cladding tube's maximum circumferential strain was smaller than or equal to the Zircaloy-4 cladding tube. These results indicate that the FeCrAl-ODS cladding tube has higher strength at high temperatures than the conventional Zircaloy cladding tube. The FeCrAl-ODS cladding tube did not fracture after being subjected to an axial restraint load of $$sim$$5000 N, which is more than 10 times higher than the axial restraint load estimated for existing LWRs, during quenching, following isothermal oxidation at 1473 K for 1 h. The FeCrAl-ODS cladding tube was hardly oxidized during this isothermal oxidation condition. However, it melted after a short oxidation at 1673 K and fractured after abnormal oxidation at 1573 K for 1 h. Based on these results, the FeCrAl-ODS cladding tube should not fracture in the time range expected during LOCAs below 1473 K, where no melting or abnormal oxidation occurs.

報告書

プルトニウム燃料第二開発室の廃止措置状況; GB No.W-9、F-1及び内装設備の解体

永井 佑哉; 周治 愛之; 川崎 猛; 會田 貴洋; 木村 泰久; 根本 靖範*; 小沼 武司*; 冨山 昇*; 平野 耕司*; 薄井 康弘*; et al.

JAEA-Technology 2022-039, 117 Pages, 2023/06

JAEA-Technology-2022-039.pdf:11.96MB

日本原子力研究開発機構は多くの原子力施設を保有しているが、その多くで老朽化・高経年化への対応、東日本大震災及び福島第一原子力発電所の事故を受けた耐震化や新規制基準への対応が求められ、多額の予算を要する状況である。このため、役割を終えた原子力施設についても根本的なリスク低減及び維持管理費用の削減のために施設の廃止措置を進めることが望ましいが、廃止措置及び発生する放射性廃棄物の処理処分に必要な施設の整備・維持管理にも多額の費用が必要となる。この状況を踏まえ、原子力機構では(1)継続利用する施設を絞り込む「施設の集約化・重点化」、(2)新規制基準・耐震化対応、高経年化対策、リスク低減対策等の「施設の安全確保」及び(3)廃止措置、廃棄物の処理処分といった「バックエンド対策」を3つの柱とした「施設中長期計画」を策定した。本計画において、プルトニウム燃料第二開発室は廃止施設として位置付けられており、施設内に設置された設備の解体撤去を進めている。今回の解体撤去対象は、焙焼還元炉、ペレット粉砕設備、これらを包蔵するグローブボックスNo.W-9及びW-9と隣々接の工程室内に設置されているグローブボックスNo.D-1とを連結するトンネル形状のグローブボックスNo.F-1の一部であり、許認可等による約4年の作業中断期間を含めて平成26年2月から令和2年2月の約6年間をかけて作業を実施した。本報告書では、本解体撤去における作業実績、解体撤去を通して得られた知見をまとめたものである

論文

Investigation of the oxidation behavior of Zircaloy-4 cladding in a mixture of air and steam

根本 義之; 石島 暖大; 近藤 啓悦; 藤村 由希; 加治 芳行

Journal of Nuclear Materials, 575, p.154209_1 - 154209_19, 2023/03

 被引用回数:1 パーセンタイル:27.23(Materials Science, Multidisciplinary)

著者らはこれまでジルコニウム合金製の燃料被覆管について、空気と水蒸気の混合雰囲気中での酸化試験を実施し、乾燥空気中よりも空気と水蒸気の混合雰囲気中において酸化が速くなる場合のあることを報告してきた。このような酸化は使用済み燃料プール(SFP)の重大事故時や、原子炉圧力容器への空気侵入事故時に起こることが懸念されるため、詳細な検討が必要である。そのためジルカロイ4製の被覆管の酸化試験を、空気と水蒸気の混合比を変化させた環境中で800$$^{circ}$$Cの温度条件で実施し、酸化試験データに基づいて酸化速度定数の評価、酸化試験後の試料について、酸化層の詳細評価,水素吸収量の評価等を行った。その結果、酸化の極初期におけるジルコニウム窒化物(ZrN)の生成や、試料表面の全面に拡がる多孔質な酸化層の成長などが、空気と水蒸気の混合雰囲気中での酸化挙動に影響していることが確認された。以上に基づき、乾燥空気中と、空気と水蒸気の混合雰囲気中での酸化メカニズムの違いについて議論を行った結果を報告する。

論文

Experimental investigation of spray cooling behavior in 4$$times$$4 simulated fuel bundle

永武 拓; 柴田 光彦; 吉田 啓之; 根本 義之; 加治 芳行

Journal of Nuclear Science and Technology, 60(3), p.320 - 333, 2023/03

 被引用回数:0 パーセンタイル:0.01(Nuclear Science & Technology)

福島第一原子力発電所事故において、使用済み燃料プールの冷却機能喪失により使用済み燃料の破損が懸念された。事故後、使用済燃料プールシビアアクシデント時において使用済み燃料プールの冷却に関する対応が求められている。この対策として可搬式スプレイを用いた冷却が考案されており、可搬式スプレイによる冷却性能評価が必要となっている。本報では、スプレイ冷却に関する知見及び冷却過程データ取得のための試験として、4$$times$$4模擬燃料集合体を用いたスプレイ冷却における集合体内温度分布データの取得を実施した結果について報告する。

論文

Damage evaluations for BWR lower head in severe accident based on multi-physics simulations

勝山 仁哉; 山口 義仁; 根本 義之; 古田 琢哉; 加治 芳行

Proceedings of ASME 2022 Pressure Vessels and Piping Conference (PVP 2022) (Internet), 9 Pages, 2022/07

To assess rupture behavior of the lower head of reactor pressure vessel in boiling-water-type nuclear power plants due to severe accident like Fukushima Daiichi, we have been developing an analysis method based on coupled analysis of three-dimensional multi-physics simulations composed of radiation transport, thermal-hydraulics (TH) and thermal-elastic-plastic-creep analyses. In this simulation, Monte Carlo radiation transport calculation is firstly performed by using PHITS code to compute proton dose distribution considering molten conditions of core materials. Then the deposit energies at each location is imported into TH analysis code ANSYS Fluent with the same geometry and temperature distribution is simulated by thermal-fluid dynamics. Finally, temperature distribution obtained from TH analysis is applied to thermal-elastic-plastic-creep analyses using FINAS-STAR and then damage evaluation is carried out based on several criterions such as Kachanov, Larson-Miller-parameter, melting point. To conduct such analyses, we also have continued to obtain experimental data on creep deformation in high temperature range. In this study, to predict time and location of reactor pressure vessel (RPV) lower head rupture of boiling water reactors (BWRs) considering creep damage mechanisms, we performed creep damage evaluations based on developing analysis method by using detailed three-dimensional model of RPV lower head with control rod guide tubes, stub tubes and welds. From the detailed analysis results, it was concluded that failure regions of BWR lower head are only the control rod guide tubes or stub tubes under simulated conditions.

論文

Study on loss-of-cooling and loss-of-coolant accidents in spent fuel pool; Confirmation of fuel temperature calculation function with oxidation reaction in the SAMPSON code

鈴木 洋明*; 森田 能弘*; 内藤 正則*; 根本 義之; 加治 芳行

Mechanical Engineering Journal (Internet), 7(3), p.19-00450_1 - 19-00450_17, 2020/06

本研究では使用済み燃料プール(SFP)における重大事故解析のため、SAMPSONコードの改良を行った。空気中酸化モデルとして、ジルカロイ4(ANLモデル)とジルカロイ2(JAEAモデル)の酸化試験データに基づく、それぞれの酸化モデルをSAMPSONコードに導入した。改良コードの有効性確認のため、米国サンディア国立研究所がこれまでに実施した、BWR燃料集合体の実規模モデルを用いての空気中酸化試験の解析を行った。その結果、Zrの空気中酸化に基づく急激な温度上昇を良い精度で再現できた。またSFP事故解析をSFPの初期水位がゼロの場合、燃料有効長の最下端位置の場合、中間位置の場合、の3ケースについて実施した。その結果、SFPの冷却水が完全に失われ、燃料集合体中の空気の自然循環が起きる場合にのみ、事故時初期の急激な温度上昇が起きることが示された。

論文

Overview of accident-tolerant fuel R&D program in Japan

山下 真一郎; 井岡 郁夫; 根本 義之; 川西 智弘; 倉田 正輝; 加治 芳行; 深堀 智生; 野澤 貴史*; 佐藤 大樹*; 村上 望*; et al.

Proceedings of International Nuclear Fuel Cycle Conference / Light Water Reactor Fuel Performance Conference (Global/Top Fuel 2019) (USB Flash Drive), p.206 - 216, 2019/09

福島第一原子力発電所事故を教訓に、冷却材喪失等の過酷条件においても損傷しにくく、高い信頼性を有する新型燃料の開発への関心が高まり、世界中の多くの国々において事故耐性を高めた新型燃料の研究開発が進められている。本プロジェクトは、経済産業省資源エネルギー庁からの委託を受けて2015年10月から2019年3月までの3年半の間実施され、新型燃料部材を既存軽水炉に装荷可能な形で設計・製造するために必要となる技術基盤を整備することを目的に、国内の軽水炉燃料設計,安全性評価,材料開発を実施してきた人材,解析ツール,ノウハウ、及び経験を最大限活用して進められてきた。本論文では、プロジェクトの総括として、各要素技術について3年半の研究開発の成果をまとめ、日本の事故耐性燃料開発の現状と課題を整理した。

論文

Study on loss-of-cooling and loss-of-coolant accidents in spent fuel pool, 2; Fuel cladding oxidation

根本 義之; 加治 芳行; 金沢 徹*; 中島 一雄*; 東條 匡志*

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 8 Pages, 2019/05

使用済燃料プールでの事故解析を目的としたシビアアクシデントコードの高度化においては、被覆管材料の当該事故条件での酸化モデルの構築及びその導入が必要である。著者らは短尺の被覆管試料を用いた当該事故模擬の温度条件、環境条件での熱天秤を用いた酸化試験結果に基づき、酸化モデルの構築を行った。また長尺の被覆管試料を用いた当該事故模擬条件での酸化試験を行い、酸化モデルによる解析結果と実験結果について比較検討を行い、酸化モデルの検証を行った。酸化試験においては酸化反応による雰囲気中の酸素欠乏に関しても実験及び解析による評価を行い、その結果に基づき、雰囲気中の酸素欠乏の被覆管酸化挙動に及ぼす影響や、それを考慮した今後の酸化モデルの高度化について議論を行なった。

論文

Study on loss-of-cooling and loss-of-coolant accidents in spent fuel pool, 5; Investigation of cooling effects of SFP spray and alternate water injection with MAAP code

西村 聡*; 佐竹 正哲*; 西 義久*; 根本 義之; 加治 芳行

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 8 Pages, 2019/05

使用済燃料プール(SFP)で冷却機能喪失事故あるいは冷却材喪失事故が発生した場合、使用済燃料の冷却性確保の観点から、SFPに注水してプール水位を維持する必要がある。本講演では、別途提案した空気中Zr酸化反応モデルを新たに組み込んだMAAPコード5.05ベータを使用してSFPを対象とした事故進展解析を実施し、SFPスプレイおよび代替注水実施時の燃料冷却効果を評価した結果について報告する。SFPスプレイの評価においては、崩壊熱、スプレイ水の燃料集合体にかかる割合、スプレイ水滴の直径、スプレイ開始時間を解析パラメータとして用いた。使用後4ヶ月冷却した燃料を格納したSFPに、12.5kg/s (200GPM)のスプレイをSFP冷却水喪失後4時間後から使用し、その際のスプレイ水の30%が燃料集合体にかかると想定した場合、燃料被覆管の最高温度は1000K以下に抑えることができ、被覆管の破損が防げることが示された。

論文

Study on loss-of-cooling and loss-of-coolant accidents in spent fuel pool, 6; Analysis on oxidation behavior of fuel cladding tubes by the SAMPSON code

森田 能弘*; 鈴木 洋明*; 内藤 正則*; 根本 義之; 加治 芳行

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 9 Pages, 2019/05

本研究では使用済燃料プールでの事故解析を目的としてシビアアクシデントコードSAMPSONの高度化を実施した。新たに組み込んだ空気中Zr酸化反応モデルの機能確認のために、既存の酸化モデルと、本研究で開発した酸化モデルを用いて、米国サンディア国立研究所の実施したBWR燃料集合体モックアップの空気中酸化試験の解析を行った。検証解析の結果に基づき、酸化反応モデルの違いが燃料棒温度変化の解析結果に及ぼす影響及び使用済燃料プール事故時の初期水位が酸化反応挙動に及ぼす影響について検討した結果を報告する。

論文

Study on loss-of-cooling and loss-of-coolant accidents in spent fuel pool, 8; Safety margin of spent fuel in large LOCA event by the simple assessment method

染谷 崇之*; 千年 宏昌*; 渡辺 聡*; 根本 義之; 加治 芳行

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 9 Pages, 2019/05

新規制基準の下、電力各社ではSFP冷却水損失事故時の安全評価を簡易な手計算で実施しているが、その安全裕度に関しては十分な議論がなされていない。そのため、本研究ではCFD解析によるSFP冷却水損失事故の詳細評価を実施し、簡易な手計算での評価結果と比較を行った。その結果、簡易な手計算ではCFD解析に比較して100$$^{circ}$$C程度、事故時の燃料の最高温度を高く評価することが明らかになった。

論文

Study on loss-of-cooling and loss-of-coolant accidents in spent fuel pool, 1; Overview

加治 芳行; 根本 義之; 永武 拓; 吉田 啓之; 東條 匡志*; 後藤 大輔*; 西村 聡*; 鈴木 洋明*; 大和 正明*; 渡辺 聡*

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 8 Pages, 2019/05

本研究では、使用済燃料プール(SFP)の事故時における燃料被覆管の酸化モデル及びSFPに設置されたスプレイの冷却性能を評価するための数値シミュレーション手法を開発した。これらをMAAPやSAMPSONのようなシビアアクシデント(SA)解析コードに組み込み、SFPの事故時解析を実施した。数値流体力学コードを用いた解析を実施し、SA解析コードの結果と比較することにより、SFP事故の詳細を検討した。さらに、3次元臨界解析手法を開発し、SFPにおける使用済燃料のより安全な燃料配置について検討した。

論文

Study on loss-of-cooling and loss-of-coolant accidents in spent fuel pool, 4; Investigation of fuel loading effects in BWR spent fuel rack

東條 匡志*; 金沢 徹*; 中島 一雄*; 岩本 達也*; 小林 謙祐*; 後藤 大輔*; 根本 義之; 加治 芳行

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 13 Pages, 2019/05

沸騰水型軽水炉の使用済燃料プールにおける、冷却水損失,冷却不全等による事故時の安全性向上を目的として、使用済み燃料ラック内における燃料配置手法の検討を3次元解析に基づいて実施した。その際、崩壊熱の正確な評価、ラック体系の熱伝達評価による燃料温度の把握、破損時の幾何形状なども考慮した臨界性等について考慮する必要がある。本研究においては、これらに関してそれぞれ3次元体系の解析コードによる評価を行い、それらの結果を総合的に検討することにより、事故進展に及ぼす燃料配置の影響について議論を行なった。またそれらの知見に基づき、安全性向上に寄与しうる燃料配置手法について考察を行なった。

論文

Study on loss-of-cooling and loss-of-coolant accidents in spent fuel pool, 7; Analysis on effectiveness of spray cooling by the SAMPSON code

鈴木 洋明*; 森田 能弘*; 内藤 正則*; 根本 義之; 永武 拓; 加治 芳行

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 7 Pages, 2019/05

使用済燃料プール(SFP)での事故解析を目的としてシビアアクシデントコードSAMPSONの高度化を実施した。新たに組み込んだスプレイ冷却モデルの機能確認のため検証解析を実施した。また実機におけるスプレイ流量が燃料棒温度変化に及ぼす影響評価や、効率的なスプレイ冷却の手法に関する評価等を行なった。その結果、SFPの真上からスプレイを降らせることにより、冷却水損失で大気中に露出した燃料集合体の冷却を有効に行なうことができ、燃料の破損を防ぎ得ることが示された。

論文

Evaluation of the effect of spent fuel layout on SFP cooling with MAAP5.04

西村 聡*; 佐竹 正哲*; 西 義久*; 加治 芳行; 根本 義之

Proceedings of 11th Korea-Japan Symposium on Nuclear Thermal Hydraulics and Safety (NTHAS-11) (Internet), 3 Pages, 2018/11

福島第一原子力発電所の事故を受けて、日本の電力事業者は原子力規制庁より使用済み燃料プール(SFP)の安全性向上のための対策を自主的に行うことを求められている。SFP安全対策において最も重要なのはプールの水位を保つことにより冷却性を担保し、燃料破損及び再臨界を防止することである。そのために事業者らが導入しているものとしては、例えばスプレイ冷却システムや、代替注水システム、また燃料配置において出力の高い燃料と低い燃料を1対4、1対8などの比率でチェッカーボード状に配置する手法、などが挙げられる。本研究ではこのうち特に燃料配置手法の有効性について、MAAP5.04を用いた解析により評価することとした。

論文

Study on oxidation model for Zircalloy-2 cladding in SFP accident condition

根本 義之; 加治 芳行; 鬼澤 崇*; 金沢 徹*; 中島 一雄*; 東條 匡志*

Proceedings of Annual Congress of the European Federation of Corrosion (EUROCORR 2018) (USB Flash Drive), 8 Pages, 2018/09

ジルカロイ2被覆管の短尺試験片を用いて乾燥空気及び空気と蒸気混合雰囲気での高温酸化試験データに基づく酸化モデルを提案している。使用済燃料プール事故時を模擬した長尺試験片の酸化挙動を解析するために、酸化モデルを計算熱流動解析コードに提供した。空気中での酸化皮膜成長挙動は酸化モデルを用いた計算結果により良く再現できるが、空気と蒸気混合雰囲気では過度に保守的な評価となっている。事故時の使用済燃料ラックにおける雰囲気成分の変化の影響について議論した結果について紹介する。

論文

Influence of the air/steam mixing ratio in atmosphere on zirconium cladding oxidation in spent fuel pool accident condition

根本 義之; 加治 芳行; 小川 千尋*; 中島 一雄*; 東條 匡志*

Proceedings of 2017 Water Reactor Fuel Performance Meeting (WRFPM 2017) (USB Flash Drive), 10 Pages, 2017/09

使用済み燃料プールの冷却水損失事故に対応するためには、事故時に想定される空気中または空気と水蒸気の混合した雰囲気中でのジルコニウム被覆管の高温酸化挙動の把握が重要である。本研究では空気と水蒸気の混合した雰囲気中でのジルカロイ2及び4の酸化試験を行い、混合比の影響について600$$^{circ}$$Cから1100$$^{circ}$$Cの温度域での評価を行った。その結果、ジルカロイ2は900$$^{circ}$$Cから1000$$^{circ}$$C、ジルカロイ4は800$$^{circ}$$Cから1000$$^{circ}$$Cの範囲で、空気と水蒸気の混合雰囲気中での酸化速度が乾燥空気中や水蒸気中よりも速くなった。この傾向は酸化層に割れが入った、酸化過程の後半において、より顕著に見られた。この結果は、使用済み燃料プール事故解析を目的とした酸化モデルの構築においては、空気と水蒸気の混合雰囲気中での酸化挙動の考慮が重要であることを示していると考えられる。

論文

Creep damage evaluations for BWR lower head in severe accident

勝山 仁哉; 山口 義仁; 根本 義之; 加治 芳行; 逢坂 正彦

Transactions of the 24th International Conference on Structural Mechanics in Reactor Technology (SMiRT-24) (USB Flash Drive), 11 Pages, 2017/08

東京電力福島第一原子力発電所のような沸騰水型原子炉(BWR)のRPV下部ヘッドは、形状が複雑で多数の制御棒案内管が存在するため、その破損挙動は複雑である。そこで我々は、重大事故時のBWR下部ヘッド破損について、クリープ損傷機構を考慮した熱流動構造連成解析に基づく評価手法を整備した。本研究では、事故シナリオの違いを想定し、溶融デブリの深さや発熱位置の違いが破損位置に及ぼす影響について評価した。その結果、BWR下部ヘッドの破損やデブリの流出は、貫通部における制御棒案内管やスタブ管で生じることを示した。

169 件中 1件目~20件目を表示